JOR 04-0182, Upgrade Fire Alarm System, BLDG 210, Fort Monmouth, NJ.
BLDG 210 and BLDG 210 Addition.
Small Business Set-aside
Base bid
Provide all plant, labor, materials and equipment and perform all work required to "Install an Addressable Fire Alarm System in Building 210, Fort Monmouth, NJ" in strict accordance with drawings 11345-1(F1) to 11345-10(F10).
FAR 36.204 (c) $100k-250k
Construction period is 90 days.
Liquidated damages in the amount of $66.11 per day
W912CF09B0017
17 June Solicitation
TBA Site Visit
30 June Bid Opening
Drawings & Specifications will be posted to FBO and may be downloaded and copied to CD for reproduction. Files are located on the right side of the Solicitation web page on FBO. You may have them downloaded and reproduced by a reprographics firm. The WEB SITE FOR FBO is (www.fbo.gov)
To BID for this solicitation, you must meet the following Qualifications and provide Certification in each:
System Designer:
System working plans and calculations must be prepared and submitted for approval by a registered fire protection engineer (FPE) or an individual that has obtained National Institute for Certification in Engineering Technologies (NICET), Fire Alarm Systems, Level III certification (minimum) in accordance with NFPA 72.
Installer:
NICET Level I
A licensed Electrical Contractor or Fire Alarm Technician with NICET Level I certification (minimum) is required to install conduit and wiring. All Installers shall be factory trained and certified in the installation of the equipment specified for the system.
NICET Level II
Installation of field devices, termination of system wiring and circuits at the control panel require a NICET Level II certification.
NICET Level III
Supervision of personnel installing the system, programming of the control panel, testing, final acceptance test.
Files
| File | Type | Posted |
|---|---|---|
| BidAbstractW912CF09B0017.pdf | ||
| Bid Opening-Eatontown Library--09B0017.doc | DOC document | |
| 210f0402.pdf | ||
| 210f0405.pdf | ||
| 210f0403.pdf | ||
| 210f0408.pdf | ||
| 210f0409.pdf | ||
| 210f0407.pdf | ||
| 210f0406.pdf | ||
| 210f0404.pdf | ||
| 210f0410.pdf | ||
| 210f0401.pdf | ||
| W912CF09B0017 JOR 04-0182 FireAlarm B210.doc | DOC document | |
| SiteVisitFtMonmouth--09B0017.doc | DOC document | |
| Update-Solicitations.xls | XLS spreadsheet |
Show all 15
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity