JB Charleston Radio Tower Inspection & Repair Services
Closed Pre-Solicitation Posted
- Solicitation number
- FA4418JBCRADIOTOWER
- Agency
-
Air Mobility Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 811210 Electronic and Precision Equipment Repair and Maintenance
- Place of performance
- Charleston AFB, South Carolina 29404, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Air Mobility Command is seeking one-time radio tower inspection and repair services for the JB Charleston radio tower through this sources sought pre-solicitation notice. The contractor must provide comprehensive inspection services covering structural components, guy wires, antennas, cables, lighting, and grounding systems, followed by authorized repairs to address identified deficiencies. Personnel qualifications are stringent, requiring minimum 2 years tower inspection experience and specific certifications including OSHA Fall Protection Competent Person, OSHA 10/30-Hour Construction Safety, Authorized Climber certification, Tower Rescue, RF Safety Training, and First Aid/CPR/AED. The contractor must categorize deficiencies by severity levels and provide detailed reports with high-resolution geotagged photographs within 10 business days of completing the on-site inspection. As this is currently a request for information only, responses are due by August 11, 2025, with no official solicitation timeline yet established.
This opportunity is designated as a Total Small Business set-aside under NAICS code 811210 for Electronic and Precision Equipment Repair and Maintenance. The period of performance is established at 90 days from contract award for this one-time service requirement. All contractor personnel must possess REAL ID credentials for base access at Joint Base Charleston, and the contractor must develop a comprehensive site-specific safety plan addressing fall hazards, electrical hazards, and RF radiation hazards. The work scope requires full compliance with federal, state, and local regulations including OSHA, FCC, and FAA requirements, with all repairs requiring written approval from the Contracting Officer via contract modification before execution. No incumbent contractor information or specific budget ranges have been disclosed in this pre-solicitation phase.
Notice text
THIS IS A REQUEST FOR INFORMATION ONLY (SOURCES SOUGHT) AND IS NOT AN OFFICIAL REQUEST FOR QUOTATION AT THIS TIME. 628 CS requires a one-time inspection and repair service on the JB Charleston radio tower. The objective is to assess the tower's current condition, identify any deficiencies, and complete necessary repairs to ensure its safe and reliable operation. The Contractor shall provide all labor, materials, equipment, and supervision necessary to perform a comprehensive inspection and execute necessary repairs to the JB Charleston radio tower in accordance with industry best practices, applicable regulations, and the specific requirements outlined in the Performance Work Statement (PWS). Performance requirements include Inspection and repair services, safety requirements, communication requirements, regulatory and environmental compliance, personnel qualifications, deliverables, certification requirements, quality assurance, and security compliance all in accordance with the PWS. This will be for a one-time service. Please see attached PWS for additional information.
Files
| File | Type | Posted |
|---|---|---|
| PWS_JBC Radio Tower Inspection and Repair Services.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Repair Naval Reserve Training Facility B3370 | Air Mobility Command | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity