J049--FY21: Service- HVAC Air Handling Units Service

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
36C24821Q0936
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
VA caribbean Healthcare System 10 Casia Street San Juan 00921 Puerto Rico

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8 is conducting market research to identify potential sources for a future service contract to provide maintenance and repair services for 45 critical air handling units at various facilities within the VA Caribbean Healthcare System in San Juan, Puerto Rico. The scope of services includes inspection, preventative maintenance, repairs, and replacement of parts for the air handling units. The period of performance is one base year with four option years. Responses to the pre-solicitation notice are due by May 21, 2021 and should include company information, DUNS number, and confirmation that the firm can perform services under NAICS code 238220. Qualifications for contractor personnel include experience requirements and degree or certification requirements for various maintenance and repair functions.

This pre-solicitation notice does not include any set-aside designations. The main NAICS code is 238220 for HVAC equipment and commercial/industrial refrigeration equipment merchant wholesalers. The pre-solicitation notice does not name any potential incumbents or current contractors. No award values or budget ranges are provided. Key details include maintenance and repair services for 45 air handling units located across various facilities within the VA Caribbean Healthcare System in San Juan, Puerto Rico over a one base year and four option year period of performance.

Notice text

SCOPE:

The VA Caribbean Healthcare System (VACHS), 10 Casia St, San Juan, PR 00921, has a requirement for maintenance and repair service for critical air handling units. This service contract is to provide all materials, labor, supervision, tools, supplies, transportation, and equipment necessary to perform inspection, full preventive maintenance service and required repairs to the existing equipment listed in the schedule. Included are all inspections, adjustments, tests, and repairs to keep the equipment covered under this contract in continuous and reliable use at its designed capacity and efficiency. Equipment shall be maintained in accordance with terms and conditions stated herein.

The period of performance for this service contract is one base year and four option periods.

General Requirements.

1.The contractor shall furnish qualified technician(s) on the job site while in performance of Maintenance and Service of the identified Air Handling Units. Contractor shall be responsible for regular, systematic execution of the work items listed in Section IV as per manufacturers recommendations and other specifications provided in this SOW. The contractor agrees to regularly and systematically perform required maintenance of the equipment and provide callback service as conditions warrant, repair or replace all portions of the equipment included under this contract.

2. The contractor shall not perform any schedule maintenance or repair that requires the unit to be off-line or shutdown unless a VACHS representative, in coordination with the Operations Control Center, secure all power sources to the unit such as valves and electrical power main disconnect.

3. The contractor shall not manipulate any valve, control, automatic device, lock-out control or heat load transfer system unless it has been secured by the Operations Control Center.

4. Equipment shall be maintained in first-class condition to meet the initial performance ability. The equipment manufacturer's recommended maintenance and repair requirements along with other specifications delineated shall be accomplished under the scope of this contract. The contractor is responsible for the unit s conditions at the beginning of this service contract. The equipment manufacturer's maintenance requirements are considered the minimum for all equipment. If specific equipment covered by this contract requires additional maintenance for safe and reliable operation the contractor shall perform the required maintenance.

5. The contractor is responsible, under this maintenance and repair contract, for the replacement of any damaged parts such as electrical motors, fan assembly or component, valves, level control, belts, gear case, dampening device, unit structural components, assembly, unit strainer, enclosure, piping, hangers, catwalk, filtration system, lightning arrester and any other mechanical or electrical device, up to the main electrical power disconnect, that is part of the air handling unit system. All system components must always be maintained operational and clean, free of dust, grease, stains or any other that will affect the operation and appearance of the unit or unit component.

6. The contractor shall provide a systematic preventive maintenance program in order to avoid a major component failure such as fan assembly rupture that will render the unit unserviceable for a period that will affect patient care service.

7. Contractor s preventive maintenance program must include an Automated Engineering Management Software as a tool to track and manage all services performed. The engineering software will be the mechanism used to generate preventive maintenance schedules and repair services orders.

8. Contractor is responsible for the replacement of filtration components as per the unit s manufacturer specification, filtration media manufacturer recommendations or as described in this PWS.

9. A predictive maintenance program must be established. Unit vibration analysis must be documented and analyze as a mechanism to prevent unit catastrophic failure.

10. The contractor must provide a system of call back to attend any emergency, after hours, and must report within two hours on site to resolve any emergency with the units covered by this PWS.

Equipment Schedule:

Item Number

AHU Name

Location

1

Air Handling Unit 1

South Bed Tower

2

Air Handling Unit 2

South Bed Tower

3

Air Handling Unit 3

South Bed Tower

4

Air Handling Unit 4

South Bed Tower

5

Air Handling Unit 5

South Bed Tower

6

Air Handling Unit 6

South Bed Tower

7

Air Handling Unit 7

South Bed Tower

8

Air Handling Unit 8

South Bed Tower

9

Air Handling Unit 9

South Bed Tower

10

Air Handling Unit 10

South Bed Tower

11

Air Handling Unit 11

South Bed Tower

12

Air Handling Unit 12

South Bed Tower

13

Air Handling Unit 1

Community Living Center

14

Air Handling Unit 2

Community Living Center

15

Air Handling Unit 3

Community Living Center

16

Air Handling Unit 4

Community Living Center

17

Air Handling Unit 5

Community Living Center

18

Air Handling Unit 6

Community Living Center

19

Air Handling Unit 1

Surgery Intensive Care Unit

20

Air Handling Unit 30

Surgery Intensive Care Unit

21

Air Handling Unit 32

Surgery Intensive Care Unit

22

Air Handling Unit 2

Outpatient Admissions

23

Air Handling Unit 23, SPD

Building 1

24

Inpatient Pharmacy Air Handling Unit

Building 1

25

Linear Accelerator Air Handling Unit 1

Building 1

26

Linear Accelerator Air Handling Unit 2

Building 1

27

Linear Accelerator Air Handling Unit 3

Building 1

28

Air Handling Unit 1 CT Scan

Building 1

29

Air Handling Unit 2 CT Scan

Building 1

30

Air Handling Unit 3 CT Scan

Building 1

31

MRI Air Handling Unit

Building 1

32

Radio Therapy Air Handling Unit

Building 1

33

Air Handling Unit 29 Morgue

Building 1

34

Air Handling Unit Foot Clinic

Building 1

35

Air Handling Unit 18 Kitchen VCS

Building 1

36

Supply Fan Food and Nutrition

Building 1

37

Air Handling Unit Cardio Cath 1

Building 1

38

Air Handling Unit Cardio Cath 2

Building 1

39

Air Handling Unit Swimming Pool

Building 1

40

Air Handling Unit RT 1 Operating Rooms

Building 1

41

Air Handling Unit 2R Operating Rooms

Building 1

42

Supply Fan 1 A B9 Mechanical Room

Building 1

43

Supply Fan 1 B B9 Mechanical Room

Building 1

44

Supply Fan 1 C B9 Mechanical Room

Building 1

45

Air Handling Unit for UPS

Building 1

QUALIFICATION:

The Contractor personnel must have five years of experience in the maintenance, repairs, and installation of air handling units.

The contractor personnel responsible for dismantling, repair, relocate, modify, maintain, align, adjust, lubricate, weld, rigging, and keep up with the preventive maintenance and repair service for the identified pieces of equipment in this contract must possess a technical degree as an Industrial Mechanic.

The contractor personnel responsible for the electrical installation, maintenance, troubleshooting and repair of all electrical or electronic components for the identified pieces of equipment in this contract must possess a technical degree and be certified to practice the trade by federal or local jurisdiction.

The contractor personnel responsible for the heat transfer process, filtration process or air conditioning process of the identified units in this maintenance and repair service contract must possess a technical degree as an Air Conditioning Equipment Technician.

The contractor personnel must possess the 30 Hrs. OSHA training course in Construction Safety & Health.

The contractor personnel that will manage the contract execution and in charge of contract management must have a Mechanical Engineering degree from an accredited educational institution.

DESCRIPTION:

THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A REQUEST FOR INFORMATION Only. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. This Request for Information is intended for Socio-economic groups: Service Disable Veteran Owned Small Business, Veterans Owned Small Business, Women Owned Small Business, Small Business and Large Business. Because this is a Request for Information announcement, no evaluation letters and/or results will be issued to the respondents. No solicitation exists. Therefore, do not request a copy of the solicitation. The Department of Veterans Affairs Service Area Office East/Network Contracting Office 8, San Juan, Puerto Rico Services Team, is conducting market research to identify potential sources with the intention to award Service Contract.

Responses to this notice should include company name, address, point of contact, phone number, fax number and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS). NAICS Code is 238220. This procurement will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Telephone responses will not be accepted. Responses must be received in writing no later than 10:00am Eastern Standard Time (EST) on May 21, 2021. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff in regard to this requirement, as they are not authorized to discuss this matter related to this procurement action, all questions will be addressed during the solicitation stage by the Contract Specialist. All firms responding to this Request for Information are advised that their response is not a request for proposal therefore will not be considered for a contract award.

Files

File Type Posted
36C24821Q0936.docx DOCX document

Notice history

Notice Type Posted
J041--FY21:HVAC Air Handling Units Service Award Award Notice
J041--HVAC Air Handling Units Service Contract Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
J041--HVAC Repair Department of Veterans Affairs Central Arkansas Veterans Healthcare System Little Rock AK 72205 · NAICS 238220 Veterans Integrated Service Network 16 No set-aside
FY27 HVAC Maintenance Service Fort Myer, Virginia 22211, United States · NAICS 238220 MICC Fort Sam Houston Total Small Business
J045--FY27 Boilers Maintenance & Testing Department of Veterans Affairs VA Caribbean Healthcare Syatem San Juan, Puerto Rico 00921, United States · NAICS 238220 Veterans Integrated Service Network 8 Service-Disabled Veteran-Owned Small Business
J041--White City B249 SE HVAC Repair NAICS 238220 Veterans Integrated Service Network 20 No set-aside
Replacement of 10 Ton HVAC Unit, Bldg. 11, PR ANG Carolina, Puerto Rico 00979, United States · NAICS 238220 Army National Guard Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors