J046--Backflow Prevention Testing and Repairs

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C25225Q0504
Agency
Veterans Integrated Service Network 12 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
221310 Water Supply and Irrigation Systems
PSC
J046 Maint/Repair/Rebuild Of Equipment- Water Purification And Sewage Treatment Equipment
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12 is seeking a contractor to provide backflow prevention testing and repairs at the Edward Hines Jr. VA Medical Center in Hines, Illinois, and the Joliet VA Community Based Outpatient Clinic. The solicitation requires annual testing, certifications, repairs, and emergency repairs for 192 backflow prevention devices manufactured by various companies including Watts, Wilkins, Apollo, Ames, and Febco, ranging from 1/2-inch to 10-inch models located throughout multiple buildings. Contractors must be licensed plumbers in Illinois with Cross-Connection Control Device Inspector (CCCDI) certified technicians and demonstrate at least three years of experience in backflow prevention testing. The evaluation will consider price, technical capability, past performance, and veteran-owned small business status. The original solicitation deadline was July 11, 2025, at 10:00 AM CDT, but has been extended to July 15, 2025, at 10:00 AM CDT, with a mandatory site visit scheduled for July 9, 2025.

This opportunity is 100% set aside for small businesses under NAICS code 221310 (Water Supply and Irrigation Systems) with a size standard of $41 million, and no current incumbent contractor is identified in the documentation. The contract structure is a 5-year Indefinite Delivery/Indefinite Quantity (IDIQ) arrangement with five one-year ordering periods from August 1, 2025, to July 31, 2030, featuring a minimum guarantee of $100 and a maximum ceiling of $200,000. The 192 backflow prevention devices are distributed across multiple buildings numbered 1-228 at the Edward Hines Jr. VA Medical Center, located in various areas including mechanical rooms, basements, penthouses, sprinkler rooms, steam tunnels, and external locations. The devices serve diverse functional areas including domestic water systems, fire protection, boiler make-up water, chiller systems, sterilization equipment, and irrigation systems throughout the VA healthcare facilities in Illinois.

Notice text

Backflow Prevention Testing located at the Edward Hines Jr. VA Medical Center in Hines, IL.

Attachments

Files attached to this notice, newest first
File Type Posted
36C25225Q0504 0001.docx DOCX document
Solicitation 36C25225Q0504.pdf PDF
Wage Determination Cook County 2015-5017 rev 29 dated 5.12.2025.pdf PDF
Attachment A Equipment List.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
J046--Backflow Prevention Testing and Repairs Award Award Notice
J046--Backflow Prevention Testing and Repairs This notice · Latest solicitation Solicitation
J046--Backflow Prevention Testing and Repairs Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity