INTENT TO SOLE SOURCE: Self-Priming, Self-Powered Flood Water Abatement or Mitigation Pumps
Closed Special Notice Posted
This opportunity was awarded. See the award notice from .
- Agency
-
ENDIST Rock Island
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 33391 Pump and Compressor Manufacturing
- PSC
- 4310 Compressors And Vacuum Pumps
- Place of performance
- Pleasant Valley, Iowa 52767, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers Rock Island District has issued a Special Notice regarding its intent to conduct a sole source procurement for self-priming, self-powered flood water abatement or mitigation pumps. The notice is being published to replace aging pump sets that support the National Flood Fight Material Center's flood control and coastal emergency response efforts.
The purpose of this Special Notice is to inform interested parties of the Army Corps' plan to procure replacement pump sets capable of specific flow rates, total dynamic head, and solids handling capabilities. The notice includes a deadline of August 26, 2024 for interested parties to submit capability statements demonstrating their ability to meet the stated requirements. While this is not a solicitation for competitive quotes, the government will consider any responses received and reserves the right to determine whether to conduct a competitive procurement based on the information provided. Respondents must submit clear and convincing documentation of their qualifications to the specified contracting personnel.
Notice text
NOTICE OF INTENT TO AWARD SOLE SOURCE PROCUREMENT:
The U.S. Army Corps of Engineers Rock Island District (USACE) will be issuing a sole source requirement in support of the National Flood Fight Material Center (NFFMC) to replace four, six, and eight inch diesel Godwin Dri-Prime Model CD100S, CD150S, and CD225M, auto-priming pump sets that are approaching or have exceeded their lifespan and require replacement or permanent transfer to staging areas around the nation to assist flood fight response efforts. This pump set is capable of flows of 1065, 2290, and 3200 Gallons Per Minute (GPM), Total Dynamic Head (TDH) of 180 feet, and solids handling up to 1.75, 3, and 3 1/8 inches in diameter for the 4, 6, and 8-inch pumps respectively. These replacement pumps are needed to support flood control and coastal emergencies response efforts. NOTE - The 4, 6, and 8-inch Self-Priming, Self-Powered Flood Water Abatement or Mitigation Pump must meet the ANSI/FM 2510 American National Standard for Flood Mitigation Equipment testing protocol standard. Justification for this sole source procurement is in accordance with FAR 13.106-1(b)(2) soliciting from a single source.
THIS NOTICE OF INTENT IS NOT A SOLICITATION OR REQUEST FOR COMPETITIVE QUOTES. However, if any interested party believes that they can meet the above requirement, they may submit a capability statement. All information furnished must be in writing and must contain sufficient detail to allow USACE to be able to determine if the interested party can perform the requirement described herein. Responses will be considered by the Government, however, a determination by the Government not to compete the proposed acquisition based upon responses of this notice is solely within the discretion of the Government. USACE will NOT be responsible for any costs incurred by interested parties in responding to this notice of intent. Only written responses will be considered. Interested parties are encouraged to furnish information by email only with RESPONSE TO INTENT TO SOLE SELF-PRIMING, SELF-POWERED FLOOD WATER ABATEMENT OR MITIGATION PUMPS in the subject line. All documents submitted will not be returned. All interested parties shall submit clear and convincing documentation demonstrating their capabilities to satisfy the requirements listed above to Allison Longeville, Contract Specialist, by email at allison.a.johnson@usace.army.mil and to Ryan Larrison, Contracting Officer, by email at ryan.r.larrison@usace.army.mil.
Notice history
| Notice | Type | Posted |
|---|---|---|
| Self-Priming, Self-Powered Flood Water Abatement or Mitigation Pumps | Award Notice | |
| This notice | Special Notice |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Pump, centrifugal | Land and Maritime | No set-aside | |
| Generation and Delivery of Meteorological and Hydrological Forecasts for the Western Washington and Northwest Montana River Basins | ENDIST Seattle | No set-aside | |
| Temporary Perimeter Flood Barriers | ENDIST Rock Island | No set-aside | |
| Notice of Intent to Award Single Source - Flow 3D Software Maintenance | ENDIST Walla Walla | No set-aside | |
| Notice of Intent to Sole Source - Replacement Marine Fire Detection and Alarm System – Motor Vessel Quincy | ENDIST Rock Island | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity