Install- compressed air line

Closed Solicitation Posted

Solicitation number
140G0325Q0076
Agency
Office of Acquisitions and Grants US Geological Survey, Department of the Interior
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
N043 Installation Of Equipment- Pumps And Compressors
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Geological Survey (USGS) Office of Acquisitions and Grants is seeking a contractor to install a compressed air line system at its West Sacramento Project Office. The solicitation, numbered 140G0325Q0076, requires the installation of approximately 650 feet of header pipe with 24 air drops in a 16,000 square foot warehouse, with each drop positioned 4 feet from the floor and terminated with a universal air chuck. Potential offerors must be registered in SAM.gov, licensed in California, and demonstrate technical capability, capacity, experience, and past performance. The contract will be awarded using a lowest price technically acceptable method, with quotes due electronically by April 14, 2025, at 12:00 Pacific Time. Evaluation will focus on technical merit, contractor qualifications, and pricing competitiveness.

This procurement is a total small business set-aside under NAICS code 238220 for Plumbing, Heating, and Air Conditioning Contractors, with a size standard of less than $45.0 million annually. The contract is a firm-fixed price purchase order with a project value between $25,000 and $100,000. The period of performance is from April 21, 2025, to June 20, 2025, with the work to be completed at the USGS West Sacramento Project Office in California. The solicitation includes a Davis-Bacon wage determination, which establishes prevailing wage rates for various construction trades. Contractors will be required to comply with all state and local codes, obtain necessary permits, and potentially obtain hot work permits. The project involves specialized technical requirements, including the use of 25MM aluminum pipe for the main line and specific piping configurations for branch drops.

Notice text

INSTALL- COMPRESSED AIR LINE

Attachments

Files attached to this notice, newest first
File Type Posted
Sol_140G0325Q0076_Amd_0001.pdf PDF
140G0325Q0076_Amend_1_QandA_0001.pdf PDF
Sol_140G0325Q0076.pdf PDF
Davis-Bacon_Act_WD___CA20250007.pdf PDF
Attachment_1-140G0325Q0076-_MAP-_Pictures.pdf PDF

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity