ILWW New Carport
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- W912EK24Q0032
- Agency
- ENDIST Rock Island US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 332311 Prefabricated Metal Building and Component Manufacturing
- Place of performance
- Peoria, Illinois 61603, United States
- Points of contact
-
- Nicholas Moore nicholas.m.moore@usace.army.mil (309) 782-6605
- Kate Behrens katherine.d.behrens@usace.army.mil (309) 704-5909
Notice details come from SAM.gov. Updated .
About this opportunity
The US Army Corps of Engineers, Rock Island District, Illinois Waterway Project (ILWW) has a requirement for the supply and installation of one carport to provide protection for machinery and cranes. The carport specifications include a 30' x 45' x 12' vertical roof design with 3 closed sides, gable-only front, and engineer certification for up to 130mph winds and 40 lbs. per square foot snow load. The contractor will be responsible for providing all materials, tools, personnel, equipment, installation, and documents to complete the requirement within 8 weeks of award, with a 1-year or greater warranty on product and installation defects.
This requirement is set aside for total small business. No potential incumbent contractors were identified, and the award value or budget range was not provided. The carport will be installed on a gravel surface with a slight slope, and the contractor may choose from standard paint colors, with up to two colors authorized.
Notice text
The US Army Corps of Engineers, Rock Island District, Illinois Waterway Project (ILWW) has the requirement for the entire supply and installation of one carport. The carport will provide protection for machinery and cranes.
SPECIFICATIONS: 30’ x 45’ x 12’ Vertical Roof Carport with 3-Closed Sides -
Vertical Roof
Base Width 30’
Base Length 45’
Sidewalls Height 12’ (12’ horizontal clearance or greater on open/entrance end.)
Left and right sidewalls completely enclosed.
Completely enclosed back.
Gable only front, open/entrance end.
Installed location will be on gravel (CA6) that has approximately 0” to 1/8” per foot slope. The grade is comprised of approximately 18” deep compacted CA6 and below the CA6 is sand.
Engineer Certified (Building Permit not required):
- Completed installation shall be engineer certified for up to 130mph winds, or greater, and a snow load rating of 40 lbs. per square foot, or greater. Carport shall require anchoring to meet the above requirement.
The contractor shall provide all materials, tools, personnel, equipment, installation, and documents to complete the requirement.
After receipt of order (ARO), the Contractor shall complete within 8-weeks.
1-year, or greater, warranty on product and installation defects, which starts after installation is complete by the Contractor.
Quote for standard paint colors. One and no more than two colors will be provided for panels after notice to proceed is authorized.
Notice history