Hydrant Fuel System In-line Aviation Fuel Quality Monitor/Analyzer for Flushing Operational Efficiency

Closed Solicitation Posted

Solicitation number
AF191-030
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
541715 Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology)
PSC
AC12 National Defense R&D Services; Department Of Defense - Military; Applied Research
More information

Notice details come from DoD SBIR/STTR (DSIP). Updated .

Notice text

DoD SBIR topic AF191-030

Component: USAF

Command: AFSC-TINKER

Phase: SBIR Program Phase I Action

Technology Areas: Air Platform

Keywords: aviation turbine fuel; microbial contamination; sensor; hydrant system; Flushing; free water; particulate contamination; fuel cleanliness

Objective:

Develop and demonstrate or identify a Commercial-Off-The-Shelf (COTS) sensor system with an in-line and a quick connect design to continually monitor, analyze, and report in real-time aviation fuel cleanliness (solids, water, and microbial) changes during aviation turbine fuel hydrant system pipeline flushing operations.

Description:

The Air Force currently conducts fuel system flushing operations on a monthly basis to remove unwanted solids, water, and microbial contamination in its constant pressure closed loop hydrant systems. Hydrant systems are flushed using high-speed or turbulent flow, rotating the fuel through the various internal screens and filter water separators to dislodge and remove the contaminants. Currently, a manual monitoring method is used to determine fuel cleanliness changes as a result of flushing operations. This includes collecting fuel samples at regular intervals and subjecting them to various test methods to determine solid and free water levels until established fuel cleanliness standards are achieved. These actions take manpower and laboratory capabilities. Several refueling hydrant systems continue to shed rust particles at high rates resulting in out-of-cycle filter replacement, increased maintenance and hazardous material disposal costs. While filtration removes most particles greater than 1 um in diameter, the amount of material being delivered to aircraft as particles less than 1 um is unknown and in some cases may be significant. Periodic flushing at laminar flow rates is insufficient to clear accumulated water and polar contaminants from low points. Laminar flow is characterized by near zero velocity at pipe walls and maximum velocity at the center. Low points and dips in the hydrant loop can accumulate a mixture of water and up to 50% Fuel System Icing Inhibitor (FSII). This mix can become very acidic and shorten the lifetime of the hydrant system. It is not known whether maximum flow rates are sufficient to clear these low points of accumulated water. Water that has accumulated in pipeline low points may be colonized by microbes before the FSII concentration becomes lethal. Anaerobic microbes isolated within a protective biofilm are known to promote pit corrosion and are able to tolerate extreme levels of FSII without disruption. Biofilms are known to resist disruption on fast flowing stream beds and may be equally resistant to normal flushing rates in fuel hydrant system. Passive draining procedures for low point sumps may not provide sufficient turbulence to remove contaminants. An in-line or a quick connect sensor system is needed to monitor and analyze in real time aviation fuel cleanliness changes during hydrant system pipeline flushing operations. The system needs to be able to monitor/analyze aviation fuel samples from various points during flushing operations to include at a minimum downstream of issue filtration and prior to product return to allow for product comparison to ensure the operation is improving fuel cleanliness and quality. System would need to monitor for solid particulate levels, water content (free), microbial contamination, and various fuel properties. Solid contamination levels to be reported in either mg/L or ISO Codes. Water content (free) to be reported in ppm. Microbial contamination to be reported as either present or the same limits as current commercial microbial contamination standards. The sensor system must be able to safely operate in a National Fire Protection Association (NFPA) or ATmosphere EXplosibles (ATEX) safety environment.

Phase I:

Develop an approach or identify a COTS sensor system that can be adapted for the design of an in-line and quick connect sensor system that can monitor and report in real time aviation fuel cleanliness during fuel hydrant system flushing operations. System would need to monitor for solid particulate levels, water content (free), microbial contamination, and various fuel properties. Conduct proof of principle experiments supporting the concept and provide evidence of the feasibility of the approach.

Phase II:

Build or using a COTS sensor system, evaluate two prototypes (one an in-line prototype and the second a quick connect prototype) able to continuously monitor and report fuel cleanliness levels during real time hydrant system flushing operations and other requirements provided by the Air Force. The prototypes will be used to demonstrate and validate the technology under field conditions. The Phase II final report will document the results and provide transition plans needed to integrate and implement into Air Force fuels hydrant system infrastructure and integration with existing control systems.

Phase III:

Technology fielded under this SBIR could have an impact on aviation fuel quality surveillance and fuels infrastructure operations. The intended transition path being implementation at all Air Force operating locations having aviation turbine constant pressure closed loop fuel hydrant system to monitor improvements in fuel cleanliness during hydrant system flushing operations. It also has potential expansion to other Services and Defense Logistics Agency Energy. The fielding of this technology will also have a 50% or greater emphasis on applications in the commercial aviation fuel hydrant systems or in commercial fuel analysis.