H341--Evaluation of Boilers, Deaerator & Condensate Tanks

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
36C24222Q0043
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
541330 Engineering Services
Place of performance
Department of Veterans Affairs Northport, New York 11768, United States

Notice details come from SAM.gov. Updated .

Notice text

This notice is for Solicitation Number 36C24222Q0043 Evaluations of Boilers, Deaerator & Condensate Tanks at Northport VA Medical Center, Northport, NY. 11768.

This shall be a Service-Disabled Veteran Owned Small Business Set-Aside (SDVOSB). As a result, all SDVOSB's may submit a bid, which will be considered by the agency. This project is classified under NAICS Code 541330 and has a size standard of $16.5 Million. The cost estimate range for this project is between $100,000 and $250,000.

SCOPE OF WORK

The consultant shall supply all labor, material and equipment to inspect and test the boilers and ancillary equipment at the Northport, VAMC. The work shall be documented in a full report of findings and recommendations. The report must be stamped by a licensed professional engineer. The following is a general list of equipment that must be addressed.

Boilers (Useful Life Expectancy = 40 years)

Boiler No. 1: Keeler, D Type, Water Tube Design, 40,000 PPH @ 100 PSIG Steam Pressure. MAWP 250 PSIG. National Board No. 4468. Serial No. 14651-1, Year Built: 1968.

Boiler No. 2: Keeler, D Type, Water Tube Design, 40,000 PPH @ 100 PSIG Steam Pressure. MAWP - 250 PSIG. National Board No. 4469. Serial No. 14651-2, Year Built: 1968.

Boiler No. 3: Keeler, D Type, Water Tube Design, 40,000 PPH @ 100 PSIG Steam Pressure. MAWP - 250 PSIG. National Board No. 1470. Serial No. 14651-3, Year Built: 1968. (Derated for 20,000 PPH)

Boiler No. 4: Keeler, D Type, Water Tube Design, 40,000 PPH @ 100 PSIG Steam Pressure. MAWP - 250 PSIG. National Board No. 4471. Serial No. 14651-4, Year Built: 1969.

Deaerator (DA) - (Useful Life Expectancy = 30 years)

Deaerator: Allied Steel Products Manufactured for Cochrane, Division of Crane Company, National Board No. 10959, Serial No. P-87-03A, Type: Uni-Pac Spray-Tray., MAWP = 30 PSI @ 650 Deg. F., Year Built 1987, Shell thickness - .250 Nominal. Head Thickness - .312 Nominal

Condensate Receiver tank (Useful Life Expectancy = 40 years)

Condensate Tank: Allied Steel Products Manufactured for Cochrane, Division of Crane Company, National Board No. 10986, Serial No. N86-151, MAWP = 30 PSI @ 650 Deg. F., Year Built 1987, Shell thickness - .250 Nominal. Head Thickness - .312 Nominal.

A complete description of the statement of work including specifications will be released with a solicitation.

All other details and information, including specification shall be contained in the solicitation which shall be posted on https://beta.sam.gov. The solicitation will be released on or about 10/18/2021. The response submittal address, date and time will be included in the solicitation. This project requires payment bond. All prospective bidders must be currently registered in www.sam.gov and be registered and verified as a SDVOSB in www.vip.vetbiz.gov at the time of offer submission and before award of this procurement.

End of Description.

Files

File Type Posted
36C24222Q0043.docx DOCX document

Notice history

Notice Type Posted
H341--Evaluation of Boilers, Deaerator & Condensate Tanks Latest solicitation Solicitation
This notice Original Pre-Solicitation

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors