Grease Trap Pumping FY-2018
Closed Solicitation Posted
- Solicitation number
- RFQTP140004
- Agency
-
Federal Correctional Complex Florence
Correctional Facilities, Department of Justice
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 562991 Septic Tank and Related Services
- PSC
- Not on record
- Place of performance
- FCC Florence, 5880 State Highway 67 S Florence, Colorado 81226, United States
Notice details come from SAM.gov. Updated .
Notice text
3 versions
Update #3 · Latest ·
Cancelation of Solicitation Number RFQTP140004 in its entirety.
Update #2 ·
Solicitation RFQTP140004 will be canceled in its entirety.
Update #1 ·
1.) Grease trap pumping for FY-18, 12,000 gallon interceptors at ADX, USP, and FCI. two 6,000 gallon interceptors at the FPC. 4EA
-1st Quarter
-2nd Quarter
-3rd Quarter
-4th Quarter
2.) Super Clean (One institution per quarter so every institution is done once per year.)4EA
Summary of Work
There are currently 5 grease interceptors at FCC Florence. The interceptor locations and sizes are as follows: ADX has one 1 2,000 gallon interceptor, USP has one 12,000 gallon Interceptor, FCI has one 12,000 gallon interceptor, and FPC has two 6,000 gallon interceptors. The amount and hardness of grease in each interceptor will vary by how long it has been since the last pumping, the number and type of meals prepared, and the quality of the last cleaning. The amount of time allowed at each interceptor location may be affected by security and institutional needs.
Each interceptor is to have a minimum of a basic cleaning quarterly. Scheduling of each quarterly visit will be at the FCC Florence's discretion. Each quarterly visit is to include pumping each interceptor down as far as possible within the allotted timeframe, hauling, manifesting, and disposal of the waste per Colorado Department of Public Health regulations. This will be done through surface access only.
Each interceptor will also require a thorough cleaning once a year. This can be completed one interceptor per quarter as long as each of the interceptors is completed once yearly. A thorough cleaning is to include pumping the interceptor to the bottom, entry using OSHA-mandated "Confined Space Entry" permitting, equipment, and trained personnel, and a cleaning of the inside of the interceptor through the use of scrapers and high-pressure jetting as needed. FCC Florence reserves the right to cancel the contract at their discretion.
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners