General Services Administration: Office Space-Office Lake Charles, LA
Closed Pre-Solicitation Posted
- Solicitation number
- 2LA0242
- Agency
-
Region 6
Public Buildings Service, General Services Administration
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 531190 Lessors of Other Real Estate Property
- PSC
- X1AA Lease/Rental Of Office Buildings
- Place of performance
- Fort Worth, Texas 76102, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The General Services Administration (GSA) is seeking to lease office space in Lake Charles, Louisiana, with a minimum of 3,652 square feet and a maximum of 4,199 square feet. The leased space must meet specific security requirements, including contiguous layout, forced entry protection, and sound attenuation measures. The lease term is 10 years, with an 8-year firm term. The agency's tenant improvement allowance is $50.46 per square foot, and the building-specific amortized capital is $25.00 per square foot. Expressions of interest are due by January 12, 2024, and the market survey is estimated to occur on January 25, 2024, with an estimated occupancy date of May 1, 2025.
This is an unrestricted procurement, with no set-aside designation. The government has not provided any information about potential incumbents or current contractors. The pre-solicitation notice does not specify any award values or budget ranges, but it does outline detailed technical and security requirements for the offered space.
Notice text
2 versions
Update #2 · Latest ·
Presolicitation Notice/Advertisement GSA Public Buildings Service
U.S. GOVERNMENT
General Services Administration (GSA) seeks to lease the following space:
State: LA
City: Lake Charles
Delineated Area: City of Lake Charles
Minimum Sq. Ft. (ABOA): 3,652
Maximum Sq. Ft. (ABOA): 4,199
Space Type: Office
Parking Spaces (Total): 7
Parking Spaces (Surface): Surface7
Parking Spaces (Structured): 0
Parking Spaces (Reserved): 7
Full Term: 10 years
Firm Term: 8 years
Option Term: N/A
Additional Requirements: AGENCY UNIQUE REQUIREMENTS
• All space must be contiguous, and preferably on the
2nd floor or higher. Space on the first floor will be
considered only when no other space is available, or if
deemed appropriate by Tenant. First floor spaces
require additional security measures.
• If the exterior skin of the building is not of substantial
construction as determined by Tenant Security (e.g.,
concrete, filled CMU) and does not meet Tenant’s
forced entry protection requirements, interior assembly
of perimeter walls must be constructed in accordance
with Wall Type A7 specifications.
• All exterior perimeter windows must have fragment
retention film, except at SCIF Rooms, which must have
film rated for RF/IR shielding and blast film, as specified
within the POR.
• All perimeter windows less than 18’-0” from grade or
accessible platform (e.g., air conditioners, fire stairs,
adjacent roofs, ledges, or windows) must have forced
entry protection such as man bars or security screening.
Assessment of accessible platform(s) will be determined
by Tenant Security.
• Design of workstation must ensure computer monitors
do not face exterior windows.
• Roofs less than 18’-0” from grade or accessible
11/2022
platform must meet the same forced entry protection
and sound attenuation requirements as the building’s
perimeter walls. Metal roofs less than 18’-0” from grade
or accessible platform must be 18-gauge or greater to
meet the same forced entry protection and sound
attenuation requirements as perimeter walls.
• Metal structure buildings that will have an “Open
Storage Secure” security posture must have the
secured perimeter constructed to meet forced entry
protection requirements, Wall Type A7, or approved
equivalent by Tenant and CO.
• If the space and/or building are of wood joist
construction or in an historical building, additional
security measures will be required and must be
approved by Tenant Security.
• Skylights must be removed or secured against forced
entry, blast, and visual observation.
• Where Tenant space adjoins another building, tenant,
or public areas, perimeter walls of Tenant space must
be constructed slab-to-slab in accordance with the
diagram for Wall Type A7. All conduits, backboxes, and
electrical devices on Tenant demising wall must be
surface-mounted on the secure side. Surface mounting
is not required if non-secured side of Wall Type A7 is
available for inspection by Tenant.
• No telephone lines, data lines, electrical service,
plumbing service, or ducts other than that required for
Tenant are permitted to pass through the space, except
with specific approval from Tenant and CO or when
routed through building space (such as electrical or
telephone closets dedicated to that use). All wiring,
conduits, and pipes running through the space and not
serving Tenant’s needs must be removed and/or
rerouted. If wiring, conduits, and pipes must not be
removed and/or rerouted, they must be enclosed with a
construction assembly compliant to secure wall
requirements.
• Future ceiling, floor slab, or demising wall penetrations
through Tenant’s secured perimeter will not be
permitted.
• If floor slab does not extend to the skin of the building,
additional security measures will be required to meet
forced entry protection, Tenant Security sound
attenuation requirements, and RF requirements.
• The office will be provided with file safes weighing
between 850 lbs and 1,000 lbs each. Although safes will
be dispersed throughout the office, floor load of the
proposed site must be capable of supporting this
additional weight. Tenant will provide Lessor and
Lessor’s team with quantity and approximate location of
safes.
• Tenant’s regular business hours are 7:00 AM to 5:30
PM; however, 24-hour access to the space and any
provided elevator service must be available 365 days
per year.
• One (1) elevator must be provided with override
11/2022
control. If the office is located on the 6th floor or above,
elevator must be on emergency power.
• Proposed site must not be within 640’-0” of any
facilities identified by ISC as “hazardous materials
transportation/ storage facilities.”
• Hazardous locations include facilities with potential
environmental threats (e.g., fuel storage areas, gas
stations, chemical manufacturing facilities, and railroad
lines transporting hazardous material).
• Special consideration should be given to exclude sites
located near hazardous areas, such as bulk storage
sites (e.g., hazardous materials storage sites, water
purification centers, above-ground fuel storage, and rail
yards).
• It is preferred that the proposed facility not be located
near “Low Risk Facilities” (e.g., day care centers, senior
centers, schools, hospitals, and
religious/rehabilitation/social service centers).
• Proposed facility must not be located within 400’-0” of
public defenders, ICE, probation offices, IRS,
universities, other businesses or facilities, deemed
unacceptable by Tenant Security for safety purposes.
This requirement may be waived by Tenant Security if
no other facility is deemed acceptable. In those cases,
enhanced security requirements may be necessary.
• Proposed Tenant spaces or facilities within 400’-0,” or
adjacent to facilities associated with foreign powers
identified in Tenant's National Security Threat List, will
not be considered.
• For proposals of space in existing buildings, standoff
distance must be provided from the curb line or nearest
point accessible by a vehicle to the façade of the
building to house the Tenant office. Refer to Appendix 3
of this POR.
• Crawl space below or attic areas above the space
proposed for Tenant’s occupancy is not preferred, and
will require additional security measures.
Agency Tenant Improvement Allowance:
Existing leased space: $50.46 per ABOA SF
Other locations offered: $50.46 per ABOA SF
Building Specific Amortized Capital (BSAC):
Existing leased space: $25.00 per ABOA SF
Other locations offered: 25.00 per ABOA SF
Offered space must meet Government requirements for fire safety, accessibility,
seismic, and sustainability standards per the terms of the Lease. A fully serviced
lease is required. Offered space shall not be in the 1-percent-annual chance/0.2-
percent-annual chance floodplain (formerly referred to as 100-year/500-Year
floodplain).
11/2022
Entities are advised to familiarize themselves with the telecommunications
prohibitions outlined under Section 889 of the FY19 National Defense
Authorization Act (NDAA), as implemented by the Federal Acquisition
Regulation (FAR). ). For more information, visit: https://acquisition.gov/FAR-
Case-2019-009/889_Part_B.
Expressions of Interest Due: 02/19/2024
Market Survey (Estimated): 5/25/2024
Occupancy (Estimated): 5/1/2025
Send Expressions of Interest to:
Name/Title: Michael Noye, Lease Contracting Officer
Email Address: Michael.noye@gsa.gov
Government Contact Information
Lease Contracting Officer Michael Noye, michael.noye@gsa.gov 817 201-
9326
Leasing Specialist Gean Collier, emma.collier@gsa.gov 817 978-4235
Update #1 ·
P
Presolicitation Notice/Advertisement GSA Public Buildings Service
U.S. GOVERNMENT
General Services Administration (GSA) seeks to lease the following space:
State: LA
City: Lake Charles
Delineated Area: City of Lake Charles
Minimum Sq. Ft. (ABOA): 3,652
Maximum Sq. Ft. (ABOA): 4,199
Space Type: Office
Parking Spaces (Total): 7
Parking Spaces (Surface): Surface7
Parking Spaces (Structured): 0
Parking Spaces (Reserved): 7
Full Term: 10 years
Firm Term: 8 years
Option Term: N/A
Additional Requirements: AGENCY UNIQUE REQUIREMENTS
• All space must be contiguous, and preferably on the
2nd floor or higher. Space on the first floor will be
considered only when no other space is available, or if
deemed appropriate by Tenant. First floor spaces
require additional security measures.
• If the exterior skin of the building is not of substantial
construction as determined by Tenant Security (e.g.,
concrete, filled CMU) and does not meet Tenant’s
forced entry protection requirements, interior assembly
of perimeter walls must be constructed in accordance
with Wall Type A7 specifications.
• All exterior perimeter windows must have fragment
retention film, except at SCIF Rooms, which must have
film rated for RF/IR shielding and blast film, as specified
within the POR.
• All perimeter windows less than 18’-0” from grade or
accessible platform (e.g., air conditioners, fire stairs,
adjacent roofs, ledges, or windows) must have forced
entry protection such as man bars or security screening.
Assessment of accessible platform(s) will be determined
by Tenant Security.
• Design of workstation must ensure computer monitors
do not face exterior windows.
• Roofs less than 18’-0” from grade or accessible
11/2022
platform must meet the same forced entry protection
and sound attenuation requirements as the building’s
perimeter walls. Metal roofs less than 18’-0” from grade
or accessible platform must be 18-gauge or greater to
meet the same forced entry protection and sound
attenuation requirements as perimeter walls.
• Metal structure buildings that will have an “Open
Storage Secure” security posture must have the
secured perimeter constructed to meet forced entry
protection requirements, Wall Type A7, or approved
equivalent by Tenant and CO.
• If the space and/or building are of wood joist
construction or in an historical building, additional
security measures will be required and must be
approved by Tenant Security.
• Skylights must be removed or secured against forced
entry, blast, and visual observation.
• Where Tenant space adjoins another building, tenant,
or public areas, perimeter walls of Tenant space must
be constructed slab-to-slab in accordance with the
diagram for Wall Type A7. All conduits, backboxes, and
electrical devices on Tenant demising wall must be
surface-mounted on the secure side. Surface mounting
is not required if non-secured side of Wall Type A7 is
available for inspection by Tenant.
• No telephone lines, data lines, electrical service,
plumbing service, or ducts other than that required for
Tenant are permitted to pass through the space, except
with specific approval from Tenant and CO or when
routed through building space (such as electrical or
telephone closets dedicated to that use). All wiring,
conduits, and pipes running through the space and not
serving Tenant’s needs must be removed and/or
rerouted. If wiring, conduits, and pipes must not be
removed and/or rerouted, they must be enclosed with a
construction assembly compliant to secure wall
requirements.
• Future ceiling, floor slab, or demising wall penetrations
through Tenant’s secured perimeter will not be
permitted.
• If floor slab does not extend to the skin of the building,
additional security measures will be required to meet
forced entry protection, Tenant Security sound
attenuation requirements, and RF requirements.
• The office will be provided with file safes weighing
between 850 lbs and 1,000 lbs each. Although safes will
be dispersed throughout the office, floor load of the
proposed site must be capable of supporting this
additional weight. Tenant will provide Lessor and
Lessor’s team with quantity and approximate location of
safes.
• Tenant’s regular business hours are 7:00 AM to 5:30
PM; however, 24-hour access to the space and any
provided elevator service must be available 365 days
per year.
• One (1) elevator must be provided with override
11/2022
control. If the office is located on the 6th floor or above,
elevator must be on emergency power.
• Proposed site must not be within 640’-0” of any
facilities identified by ISC as “hazardous materials
transportation/ storage facilities.”
• Hazardous locations include facilities with potential
environmental threats (e.g., fuel storage areas, gas
stations, chemical manufacturing facilities, and railroad
lines transporting hazardous material).
• Special consideration should be given to exclude sites
located near hazardous areas, such as bulk storage
sites (e.g., hazardous materials storage sites, water
purification centers, above-ground fuel storage, and rail
yards).
• It is preferred that the proposed facility not be located
near “Low Risk Facilities” (e.g., day care centers, senior
centers, schools, hospitals, and
religious/rehabilitation/social service centers).
• Proposed facility must not be located within 400’-0” of
public defenders, ICE, probation offices, IRS,
universities, other businesses or facilities, deemed
unacceptable by Tenant Security for safety purposes.
This requirement may be waived by Tenant Security if
no other facility is deemed acceptable. In those cases,
enhanced security requirements may be necessary.
• Proposed Tenant spaces or facilities within 400’-0,” or
adjacent to facilities associated with foreign powers
identified in Tenant's National Security Threat List, will
not be considered.
• For proposals of space in existing buildings, standoff
distance must be provided from the curb line or nearest
point accessible by a vehicle to the façade of the
building to house the Tenant office. Refer to Appendix 3
of this POR.
• Crawl space below or attic areas above the space
proposed for Tenant’s occupancy is not preferred, and
will require additional security measures.
Agency Tenant Improvement Allowance:
Existing leased space: $50.46 per ABOA SF
Other locations offered: $50.46 per ABOA SF
Building Specific Amortized Capital (BSAC):
Existing leased space: $25.00 per ABOA SF
Other locations offered: 25.00 per ABOA SF
Offered space must meet Government requirements for fire safety, accessibility,
seismic, and sustainability standards per the terms of the Lease. A fully serviced
lease is required. Offered space shall not be in the 1-percent-annual chance/0.2-
percent-annual chance floodplain (formerly referred to as 100-year/500-Year
floodplain).
11/2022
Entities are advised to familiarize themselves with the telecommunications
prohibitions outlined under Section 889 of the FY19 National Defense
Authorization Act (NDAA), as implemented by the Federal Acquisition
Regulation (FAR). ). For more information, visit: https://acquisition.gov/FAR-
Case-2019-009/889_Part_B.
Expressions of Interest Due: 1/12/2024
Market Survey (Estimated): 1/25/2024
Occupancy (Estimated): 5/1/2025
Send Expressions of Interest to:
Name/Title: Michael Noye, Lease Contracting Officer
Email Address: Michael.noye@gsa.gov
Government Contact Information
Lease Contracting Officer Michael Noye, michael.noye@gsa.gov 817 201-
9326
Leasing Specialist Gean Collier, emma.collier@gsa.gov
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Lease Space in Los Angeles, CA | Office of Leasing | No set-aside | |
| General Services Administration (GSA) seeks to lease office space in Montclair, CA | Central Office | No set-aside | |
| Solicitation: Government seeks offers for leased space in Orlando, FL | Office of Leasing | No set-aside | |
| General Services Administration (GSA) seeks to lease the following space in Washington, DC: | Central Office | No set-aside | |
| General Services Administration (GSA) Lease: Office Space FOREST, MISSISSIPPI | Region 6 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity