FXSB 26-6837 Repair Replace Hangar Roof B11525
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- FA500026Q0025
- Agency
-
Pacific Air Forces
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238160 Roofing Contractors
- Place of performance
- B11525, Jber, Alaska 99506
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
Pacific Air Forces seeks repair and replacement of the roof on Building 11525 at Fort Richardson, Alaska, a historic 113,000-square-foot facility, with proposals due July 7, 2026 at 1:00 PM local time. The procurement is set aside for total small business. Amendment 0004, effective July 1, 2026, extended the proposal deadline from July 2 to July 7 and changed the block designation from FA500026Q0026 to FA500026Q0025; offerors must acknowledge receipt of this amendment by the extended deadline.
Place of performance is 600 Richardson Drive, Building 346, Fort Richardson, Alaska 99505. The contracting office is FA5000 673 CONS, Jber, AK.
The project removes the existing built-up roof (BUR) from the barrel center section and the east-side roof low section down to existing decking, replacing it with a new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section. The south lower roof section shall receive a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. The work includes replacement of existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings, and trim. The barrel roof section spans approximately 200 feet (curved) by 280 feet; two low-roof sections span approximately 35 feet by 280 feet each; one low-roof section spans approximately 62 feet by 242 feet.
Building 11525 is a one-story steel and cast-concrete structure (CMU infill) constructed in the early 1940s and designated as historic property. A mandatory site visit is scheduled for June 8, 2026 at 12:00 PM. The NAICS code is 238160, Roofing Contractors; PSC code is Z1JZ, Maintenance of Miscellaneous Buildings. The contracting officer is David J. May.
Notice text
2 versions
Update #2 · Latest ·
Site visit is scheduled for 8 June, 2026, at 12:00PM. Building 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that?s approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section identified in Sheets AD-101 and A-101, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new.
Update #1 ·
Site visit is scheduled for 8 June, 2026, at 12:00PM. Building 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that?s approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section identified in Sheets AD-101 and A-101, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new.
Files
| File | Type | Posted |
|---|---|---|
| FA500026Q0025_AMENDMENT_ 0004_SF30.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| FXSB 26-6837 Repair Replace Hangar Roof B11525 | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| WWYK260004 - repair structural integrity, B1134, post 34 & north wall | Air Force Sustainment Center | Total Small Business | |
| GAOA Remove and Replace Roofing on Island Park Admin Site Housing Units | Forest Service | Total Small Business | |
| Market Intelligence Questionnaire JBR041 – Pallet Processing Facility/JBR044 – Rapid Deployment Facility | Department of Defense | No set-aside | |
| Munitions Maintenance and Inspection Facility and Conventional Munitions Cube Storage Addition, HIANG, JBPHH, HI | Army National Guard | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity