FRC Ground Level HVAC and Roof Replacement

Closed Pre-Solicitation Posted

Not the latest version. See the latest pre-solicitation from .

Solicitation number
09092026
Agency
Responses due
Set-aside
Woman-Owned Small Business

Opportunity facts

Place of performance
Denton, Texas, United States

Notice details come from SAM.gov. Updated .

About this opportunity

FEMA Region 6 intends to solicit roof and HVAC replacement services at the Federal Regional Center in Denton, Texas, with solicitation posting anticipated shortly and a site visit scheduled for September 9, 2026 at 10:00 a.m. CT. This procurement is set aside for Women-Owned Small Business (WOSB) concerns under the SBA Women-Owned Small Business Program.

Work is performed at 800 N. Loop 288, Denton, Texas 76209, and the Government requires the contractor to demonstrate the ability to perform within a 150-mile radius of that location. The scope includes demolition and removal of existing materials, replacement of approximately 3,000 square feet of roof membrane and insulation, installation of two commercial-grade rooftop HVAC units (5-ton each with SEER rating 18 or higher from Trane, Lennox, or York), utility and life safety coordination, inspections, testing, and related maintenance and construction support.

New roof membrane must carry a minimum 25-year materials warranty; sub-membrane insulation must meet R-35 to R-38 minimum. The contractor must provide all design services certified by a licensed Professional Engineer and comply with Davis-Bacon wage requirements and Build America, Buy America Act (BABAA) requirements. EPA-compliant refrigerant recovery and environmental waste disposal are mandatory. All contractor personnel require favorably adjudicated background investigations and must comply with DHS/FEMA security protocols, including Controlled Unclassified Information handling and mandatory insider threat and OPSEC awareness training. Period of performance is 45 days from notice to proceed, with contractor service required within five days of award. A one-year warranty on parts and labor is required upon government acceptance. Work is restricted to Monday through Friday, 8:00 a.m. to 5:30 p.m., with approval required for after-hours or weekend work.

A site visit is strongly recommended but not mandatory; interested vendors must notify Contract Specialist Barbara Gonzalez (barbara.gonzalez@fema.dhs.gov) by 9:00 a.m. CT on September 9, 2026, with company name, primary point of contact, phone number, and names of all attendees.

Notice text

Department of Homeland Security
Federal Emergency Management Agency
FEMA Region 6

FEMA Region 6 intends to issue a solicitation for the Roof & HVAC Replacement project at the Federal Regional Center located at 800 N. Loop 288, Denton, Texas 76209.

The project is anticipated to include roof replacement, HVAC replacement, and related building maintenance and operations support. Work may include demolition, removal and disposal of existing materials and equipment, installation of new roofing and HVAC systems or components, utility coordination, life safety coordination, cleanup, inspections, testing, and related maintenance, repair, and construction support necessary to complete the requirement.

This requirement is anticipated to be set aside for eligible SBA Certified Women-Owned Small Business (WOSB) concerns under the Women-Owned Small Business Program.

Due to the mission-critical nature of this requirement and the need for timely response and completion of work, the Government requires the contractor to demonstrate the ability to perform within a 150-mile radius of Denton, Texas.

Site Visit

A site visit will be conducted as follows:

Date: Wednesday, September 9, 2026
Time: 10:00 a.m. Central Time
Location: FEMA Region 6 Campus, Federal Regional Center
Address: 800 N. Loop 288, Denton, TX 76209

Attendance at the site visit is strongly recommended but not mandatory.

Offerors are requested to bring business cards to the site visit, if available.

All interested vendors that intend to attend the site visit should submit the following information to Contract Specialist Barbara Gonzalez no later than 9:00 a.m. CT on September 9, 2026. 

  1. Company name
  2. Primary point of contact name
  3. Phone number
  4. Names of all attendees who will represent the firm at the site visit

Site visit attendance information shall be sent to:

Barbara Gonzalez
Contract Specialist
barbara.gonzalez@fema.dhs.gov

Anticipated Solicitation Posting

The full solicitation, including the Statement of Work, Statement of Objectives, specifications, drawings, applicable clauses, and submission instructions, is anticipated to be posted to SAM.gov. Interested vendors are responsible for monitoring SAM.gov for the solicitation and any amendments.

Tentative Offer Due Date

Tentative offers will be due no later than:

Date: Wednesday, September 16, 2026
Time: 12:00 noon Central Time

Quotes or proposals shall be submitted in accordance with the instructions provided in the solicitation. Unless otherwise stated in the solicitation, submissions shall be emailed to:

Barbara Gonzalez
Contract Specialist
barbara.gonzalez@fema.dhs.gov

Neddra Tucker
Contracting Officer
neddra.tucker@fema.dhs.gov

Classification Information:

Set-Aside: SBA Certified Women-Owned Small Business Program Set-Aside
FAR Reference: FAR 19.15
Pre-Solicitation Notice
Roof & HVAC Replacement

NAICS Code: 236220, Commercial and Institutional Building Construction / Building Maintenance & Operations
Product Service Code: J045, Maintenance, Repair, and Rebuilding of Equipment
Place of Performance: Denton, TX 76209, United States

The evaluation will be conducted in accordance with FAR 52.212-2 and the evaluation factors stated in the solicitation. Due to the mission-critical nature of this requirement and the need for timely response and completion of work, the Government requires the contractor to demonstrate the ability to perform within a 150-mile radius of Denton, Texas. A site visit will be conducted on Wednesday, September 9, 2026, at 10:00 a.m. Central Time at FEMA Region 6 Campus, 800 N. Loop 288, Denton, TX 76209. Attendance at the site visit is strongly recommended but not mandatory. Offerors are requested to bring business cards to the site visit, if available.

Files

Notice history

Notice Type Posted
Decommission and Remove Non-Intrusive Inspection Systems Latest pre-solicitation Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z1DA--NEW: Comprehensive Roof Maintenance and Repair | 549 Dept of Veterans Affairs North Texas VA Medical centers Dallas, Texas 75218, United States · NAICS 238160 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity