NAICS code
334515 Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
PSC
6625 Electrical And Electronic Properties Measuring And Testing Instruments
Place of performance
Portsmouth, Virginia 23709, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Defense Logistics Agency (DLA) Maritime Norfolk is seeking to procure 100 units of Fluke T5-1000 Electrical Tester Kits with Holster and 1AC II Voltage Tester (Model FLUKE T5-H5-1AC II KIT) for Norfolk Naval Shipyard operations. This commercial item procurement will be awarded as a Firm Fixed Price single award contract using Lowest Price Technically Acceptable (LPTA) evaluation criteria, meaning the government will select the lowest-priced offer that meets all technical requirements. The solicitation was issued on August 7, 2025, and follows federal acquisition regulations under FAR Part 13 and FAR Subpart 12.6 for commercial items. Vendors must submit their proposals by 12:00 PM on August 13, 2025, providing only six days for response preparation. The electrical testing equipment must meet detailed technical specifications including accuracy requirements, voltage ratings up to 1000V, and various environmental and safety standards.

This opportunity is designated as a Total Small Business set-aside, restricting competition to qualifying small businesses under NAICS code 334515 with a size standard of 750 employees. No incumbent contractor is identified in the solicitation materials, suggesting this may be a new requirement or open competition. While specific award values are not disclosed, vendors are required to provide unit pricing for the 100-unit quantity, with the total contract value to be determined based on submitted proposals. The contract carries a DO-C9 priority rating under the Defense Priorities and Allocations System, indicating moderate urgency for defense operations. Performance will occur in Portsmouth, Virginia, with delivery required within two weeks after contract award to support Norfolk Naval Shipyard operations.

Notice text

The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY)

intends to award a Firm Fixed Price (FFP) Single Award Contract as Lowest Price Technically

Acceptable (LPTA) Evaluation Factors for the item listed below. The required item is for

commercial item prepared in accordance with the information in FAR Part 13 and FAR Subpart

12.6, as supplemented with the additional information included in this notice.

The Contract Line Item (CLIN) is as follows:

ITEM NO.

DESCRIPTION

QTY

U/I

UNIT PRICE

TOTAL

0001

FLUKE T5-1000

ELECTRICAL TESTER KIT WITH HOLSTER AND 1AC II VOLTAGE TESTER

MODEL#: FLUKE T5-H5-1AC II KIT

REF P/N 2PY98

100

EA

Determined by vendors

Determined by vendors

T5-600/T5-1000

Electrical Tester




 

Parts and Service

The tester is warranted to be free from defects in material and workmanship for two years, while under normal use. Parts and repairs are warranted for 90 days. For the complete warranty statement, refer to the

TS-600/TS-1000 Electrical Tester Instruction Sheet.

To order parts, or for warranty service, contact Fluke as follows: USA: 1-888-99-FLUKE (1-888-993-5853)

Canada: 1-800-36-FLUKE (l-800-363-5853) Europe: +31402-675-200

Japan: +81-3-3434-0181

Singapore: +65-738-5655

Anywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www.fluke.com.

Specifications

Accuracy is specified for one year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows:

::!;([ % of reading] + [number of least significant digits])

Temperature coefficient of 0.1 x (specified accuracy)/ °C for <18 °C or >28 °C (<64.4 °For >82.4 °F)

Serial Numbers 79560000 and Above

General Specifications

Calibration

One-year calibration cycle.

Maximum Voltage

Between any Terminal and Earth Ground

TS-600: 600 V rms, Overvoltage Category Ill, Pollution Degree 2

TS-1000: 1000 V rms, Overvoltage Category Ill, 600 V RMS, OverVoltage Category IV, Pollution Degree 2

Maximum Voltage

Between Current Fork and Earth Ground

TS-600 and T5-1000: 1000 V rms, Overvoltage Catergory Ill, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.)

Temperature

Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)

Altitude

Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)

Relative Humidity

O o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); o o/o to 75 %, 30 °C to 40 °C (86 °F to 104 °F);

O o/o to 45 %, 40 °C to 50 °C (104 °F to 122 °F)

Battery Type and Life

AA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride

Shock, Vibration

1 m drop at -10 °C to + 50 °C (14 °F to 122 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-1

1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)

Surge Protection

TS-600: 6 kV per IEC 61010, T5-1000: 8 kV per IEC 61010

Enclosure Rating

IP 52 per IEC 60529, no vacuum applied

GeneralSpecifications(continued)

RF Field Specification

0.5 % full scale + (specified accuracy) at 3 V/m

Safety

Complies with ANSI/ISA-S82.0l-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1- 92, and EN61010-11995.

EMC

EN 61326

Certifications

CE <ti®  S®IF,             C

In accordance with IEC 61010-1 54CJ

Resolution and Accuracy

Function

TS-600 Range

TS-1000 Range

Resolution

Accuracy

v

600 V rms

1000 V rms

lV

:!(1.5 % + 2 digits)

v

600V

1000V

lV

:!(1% + 1 digit)

~A

100.0A

100.0A

0.lA

:!(3 % + 3 digits)

n

10000

1000 0

10

:!(1o/o + 2 digits)

Input Characteristics

Function

Input Protection

Input impedance (nomial

T5-600

TS-1000

v

600 V rms

1000 V rms

1 MO, <100 pF ac-coupled

v

600 V rms

1000 V rms

1 MO, <100 pF

n

600 V rms

1000 V rms

n

Open Circuit Test Voltage

Short Circuit Current

1.65 V de (nominal)

<600 µA

CAT Ill protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.

CATIVprotects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.

Serial Numbers 79559999 and Below

General Specifications

Calibration

One-year calibration cycle.

Maximum Voltage Between any Terminal

andEarthGround

TS-600: 600 V rms, Overvoltage Category Ill TS-1000: 1000 V rms, Overvoltage Category Ill

Temperature

Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)

Altitude

Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)

Relative Humidity

0 o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); 0 o/o to 75 %, 30 °C to 40 °c (86 °F to 104 °F);

0 o/o to 45 %, 40 °c to 50 °C (104 °F to 122 °F)

BatteryTypeandLife

AA (2); 400 hours continuous with alkaline; 200 hours continuous with zinc chloride

T5-600/T5-1000

Electrical Tester




 

General Specifications (continued)

Shock, Vibration

1 m drop at 15 °C to 35 °c (59 °F to 95 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-11993.

Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)

Surge Protection

T5-600: 6 kV per IEC 1010-1, 1990-09: T5-1000: 8 kV per IEC 1010-1, 1990-09

Enclosure Rating

IP 52 per IEC 60529, no vacuum applied

RF Field Specification

0.5 % full scale + (specified accuracy) at 3 V/m

Safety

Complies with ANSI/ISA-S82.0l-94 for use in overvoltage category Ill (CAT Ill) locations, UL3111, CSA/CAN C22.2 No.1010.1-92, and EN61010-l 1993.

EMC

EN 50081-1, EN 50082-1

Certifications

( E c@us ct ®®

Resolution and Accuracy

Function

TS-600 Range

TS-1000 Range

Resolution

Accuracy

v

600 V rms

1000 V rms

lV

:!(1.5 % + 2 digits)

v

600V

1000V

lV

:!(1% + 1 digit)

A

100.0A

100.0A

0.lA

:!(3 % + 3 digits)

n

10000

10000

10

:!(1% + 2 digits)

Input Characteristics

Function

Input Protection

Input impedance (nomial

T5-600

T5-1000

v

600 V rms

1000 V rms

1 MO, <100 pF ac-coupled

v

600 V rms

1000 V rms

1 MO, <100 pF

n

600 V rms

1000 V rms

n

Open Circuit Test Voltage

Short Circuit Current

2.4 V de (nominal)

<600 µA

CAT 111 protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.

CAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.

Cleaning the Tester

Warning

To avoid electric shock or damage to the tester, never allow water inside the case. To avoid damaging the tester's case, never use solvents on the tester.

If the tester requires cleaning, wipe it down with a cloth that is lightly dampened with water or a mild detergent. Do not use aromatic hydrocarbons, chlorinated solvents, or methanol-based fluids when wiping down the tester.

The requirement will be solicited as a total small business set aside. The NAICS code applicable to this procurement is 334515, Electrical and Electronic Properties Measuring and Testing Instruments, with a size standard of 750 employees. The Product Service Code is 6625. The solicitation document incorporates provisions and clauses in effect through FAC 2025-04 and DFARS Change Notice 01/17/2025.

The anticipated delivery date for this acquisition is 6 weeks after receipt of contract. The solicitation, any documents related to this procurement, and all amendments issued will be in electronic form only.

The solicitation number is SPMYM125Q0137, and it is expected to be available on or about

07 AUG 2025 and posted to SAM.gov, https://sam.gov/ Quotes will be due by 12:00 PM EST on 13 AUG 2025. Responses to the solicitation notice shall be emailed to the attention of Curtis Douglas at Curtis.douglas@dla.mil  . Please make sure that the solicitation number

(SPMYM125Q0137) is included in the subject line of any email correspondence. Emails

without subject lines will not be read because of security issues.

Potential offerors are hereby notified that the solicitation and any subsequent amendments will only be available by downloading the documents at www.SAM.gov (Contracting Opportunities). The Government is not responsible for the inability of the Offeror's to access solicitation documents posted. Prospective Offeror's should also register on the interested vendor list under SPMYM125Q0137. No telephone or FAX requests will be accepted, and no hardcopy solicitation/amendment will be mailed or faxed.

All responsible sources may submit a proposal which may be considered by the Government. By submitting a quote, the offeror will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the proposal. By submission of a proposal, the offeror acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the

solicitation, except for awards to foreign vendors for work to be performed outside the United

States. Lack of registration in the SAM database will make an offeror ineligible for award.

Offerors may obtain information on registration and annual confirmation requirements by calling

1-866-606-8220, or via the Internet at https://www.sam.gov. All questions shall be submitted in

accordance with the solicitation, dates and procedures. Please direct all questions regarding this

requirement to Curtis Douglas at Curtis.douglas@dla.mil

Attachments

Files attached to this notice, newest first
File Type Posted
KO approved Solicitation SPMYM125Q0137 JML 51182700.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Fluke T5-1000 This notice · Latest solicitation Solicitation
Fluke T5-1000 Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity