About this opportunity
The U.S. Army Corps of Engineers Sacramento District seeks design, supply, and installation of integrated fire alarm and mass notification system upgrades at the Defense Ammunition Distribution Center in Tracy, California, with proposals due October 13, 2026. No set-aside applies.
Place of performance is 25600 S Chrisman Road, Building 235, Tracy, California. The work scope consolidates three existing legacy systems—Gamewell fire alarm controls, Federal Signal mass notification and voice evacuation, and King Fisher radio transceiver—into a single unified panel for approximately 49 buildings and warehouses. The contractor will also replace the central receiving system in Building 235 to accept signals from the new panels and install a backup receiving system in Building 100. The work includes all labor, material, equipment, and supervision for design and installation. The NAICS code is 238210, Electrical Contractors and Other Wiring Installation Contractors, and the PSC code is Z1JZ, Maintenance of Miscellaneous Buildings. Three amendments have been issued (Amendments 0001, 0002, and 0003); consult the attached amendments for further scope details.
Notice text
4 versions
Update #4 · Latest ·
** See attached amendment 0003 for details.** ** See attached amendment 0002 for details**.** See attached amendment 0001 for details**. the contractor will be required to provide all labor, material, equipment, and supervision to design, supply, and replace/combine the existing fire alarm controls (Gamewell),mass notification/voice evacuation (Federal Signal), and radio transceiver (King Fisher) into one panel for each building/warehouse (~49 ea). Contractor will also replace the existing central receiving system in the Central Dispatch (Building 235) to receive signal from the new panels, including a backup receiving system in Building 100.
Update #3 ·
** See attached amendment 0002 for details**.** See attached amendment 0001 for details**. the contractor will be required to provide all labor, material, equipment, and supervision to design, supply, and replace/combine the existing fire alarm controls (Gamewell),mass notification/voice evacuation (Federal Signal), and radio transceiver (King Fisher) into one panel for each building/warehouse (~49 ea). Contractor will also replace the existing central receiving system in the Central Dispatch (Building 235) to receive signal from the new panels, including a backup receiving system in Building 100.
Update #2 ·
** See attached amendment 0001 for details**. the contractor will be required to provide all labor, material, equipment, and supervision to design, supply, and replace/combine the existing fire alarm controls (Gamewell),mass notification/voice evacuation (Federal Signal), and radio transceiver (King Fisher) into one panel for each building/warehouse (~49 ea). Contractor will also replace the existing central receiving system in the Central Dispatch (Building 235) to receive signal from the new panels, including a backup receiving system in Building 100.
Update #1 ·
The contractor will be required to provide all labor, material, equipment, andsupervision to design, supply, and replace/combine the existing fire alarm controls (Gamewell),mass notification/voice evacuation (Federal Signal), and radio transceiver (King Fisher) into onepanel for each building/warehouse (~49 ea). Contractor will also replace the existing centralreceiving system in the Central Dispatch (Building 235) to receive signal from the new panels,including a backup receiving system in Building 100.
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Fire Alarm and Mass Notification Upgrades for DDJC, Tracy, CA | Pre-Solicitation | |
| Fire Alarm and Mass Notification Upgrades for DDJC, Tracy, CA | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| SACN Replace Fire Alarms and Intrusions Systems | — | Total Small Business | |
| H112--Secutron Fire Alarm testing and Maintenance at the VA Northern California Health Care System (VANCHCS) | Veterans Integrated Service Network 21 | No set-aside | |
| Z1DA--Upgrade Fire Alarm System Construction 676-22-110 | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| C1DA--NRM A/E- 528A7-27-112 Fire Alarm Panel Upgrade | Veterans Integrated Service Network 2 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity