Field-level Aviation/Ground Fuel Trace Element (Metal) Analysis
Closed Solicitation Posted
- Solicitation number
- AF191-027
- Agency
-
Oklahoma City Air Logistics Complex
Air Logistics Complexes, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 541715 Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology)
- More information
Notice details come from DoD SBIR/STTR (DSIP). Updated .
Notice text
DoD SBIR topic AF191-027
Component: USAF
Command: AFSC-TINKER
Phase: SBIR Program Phase I Action
Technology Areas: Air Platform
Keywords: aviation fuel; ground fuel; thermal stability; trace elements; trace metals
Objective:
Develop and demonstrate a portable analyzer able to provide on-site real time identification of trace elements (metals) by element and concentration in aviation or ground fuel samples at installation level or in a field environment outside of a laboratory facility.
Description:
The Air Force is looking to develop a portable trace element analyzer that will employ state-of-the-art technologies to identify and quantify trace elements in a fuel sample in the field. The Air Force currently performs trace element analysis on aviation or ground fuel samples using Inductively Coupled Plasma Optical Emission Spectroscopy in fixed regional laboratories with the specialized equipment. Trace elemental analysis is used to indicate the level of contamination of aviation turbine and ground fuels. Trace metals in aviation turbine fuels cause corrosion and deposits on turbine components at elevated temperatures. Some diesel fuels have specification limit requirements for trace metals to guard against engine deposits. Trace level copper in aviation turbine fuel can significantly accelerate thermal instability of the fuel, leading to oxidation and production of detrimental insoluble deposits in the engine. Metals such as dissolved copper degrade the storage stability or thermal stability of the aviation turbine fuel by catalytic action. Copper is the worst of these materials and is sometimes picked up during distribution from the refinery to the airport. The portable analyzer will enable personnel to initially determine the presence and level of trace element contamination in a fuel sample within 20-30 minutes and if the fuel is suitable for use or requires further analysis at a regional laboratory. The current process requires samples of suspected contaminated fuel to be collected on site and then shipped to a regional laboratory with metal analysis capability, which can take 2-10 days for results depending on site and international customs. During this transit and analysis time, fuel inventories and fuel servicing equipment are placed in a quality hold status, preventing the ability to support aircraft or ground vehicle generation and mission requirements. The portable trace element analyzer shall be capable of being stored and operated in climate conditions ranging from -25 degrees F to +135 degrees F and have the ability to operate on AC rechargeable battery or a 12-DC volt source with the use of Commercial-Off-The-Shelf (COTS) to the fullest extent possible. The analyzer will minimize hazardous waste and limit the amount of consumables required. The analyzer shall be able to detect a broad spectrum of trace elements (metals) associated with fuel contamination, oxidation, storage stability and thermal instability. Methods focusing on detection of a single element (metal) or a limited group of elements (metals) are discouraged. The following trace elements are targeted: Aluminum, Barium, Calcium, Chromium, Cobalt, Copper, Iron, Lithium, Lead, Magnesium, Manganese, Molybdenum, Nickel, Phosphorus, Palladium, Platinum, Potassium, Sodium, Silicon, Silver, Strontium, Tin, Titanium, Vanadium, and Zinc. Minimum lower detection limit is parts per million (ppm). Desired lower detection limit is parts per billion (ppb). The analyzer must be able to be updated as required as new contaminants or fuels are identified.
Phase I:
Develop an approach for the design of a trace element analyzer capable of determining the presence of trace elements (metals) in aviation turbine and ground fuels at installation level or in the field without laboratory capabilities and/or facilities. Conduct proof of principle experiments supporting the concept and provide evidence of the feasibility of the approach. Methods with a large hazardous waste disposal chain are discouraged.
Phase II:
Develop, build, and evaluate two identical prototype trace element (metal) analyzers meeting the requirements provided in the description of this SBIR topic and other requirements provided by the Air Force using COTS to the fullest extent possible. The prototypes will be used to demonstrate and validate the technology under laboratory and field conditions. The Phase II final report will document the results and provide transition plans needed to implement into production capability.
Phase III:
Technology developed under this SBIR would have a significant commercial potential in the aviation or ground fuel quality surveillance area. The intended transition path following field demonstration and validation is Air Force-wide implementation at locations storing and handling aviation turbine and ground fuels. Its purpose will be to monitor and enable early intervention with degraded fuel resulting from elevated levels of trace elements. It also has potential expansion to other Services and Defense Logistics Agency Energy. The development of this technology will have a 50% or greater emphasis on applications in the commercial fuel storage tanks or in commercial fuel analysis.