Energy Retrofits

Awarded Award Notice Posted

Solicitation number
VA25610RP0337
Agency
Veterans Integrated Service Network 19 Veterans Health Administration, Department of Veterans Affairs
Awarded
to TL Services, Inc.
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Contract number
VA256-C-1056 Federal contract award
NAICS code
236220 Commercial and Institutional Building Construction
PSC
Not on record

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

Added: Jul 26, 2010 10:23 am Modified: Sep 30, 2010 5:03 pmTrack Changes THE VA MEDICAL CENTER AT 921 NE.13TH ST OKLAHOMA CITY, OKLAHOMA 73104 HAS AWARDED A CONTRACT FOR ENERGY RETROFIT.

Update #1 ·

Added: Jul 26, 2010 10:23 am Oklahoma City VA has a need for supervision, labor and materials of Energy Retrofits and also , Design/Build (D/B) requirements for the FY10 NRM Project: #635-10-503, to be completed throughout the Oklahoma City VA Medical Center Campus consisting of the hospital and supporting structures. Total building square footage for campus is approximately 1,000,000 SF.



A. Retrofit Lighting



This portion of the project will consist of incorporating energy conservation retrofits into the existing interior lighting and exterior lighting. Retrofits will be incorporated throughout all buildings on the site (approximately 1,000,000 SF) and all adjacent parking areas.



B. Repair Heat Recovery Loops



This portion of the project will consist of repairing and upgrading the existing glycol run-around heat recovery systems that exchange heat from exhaust air streams to pre-condition incoming outside air streams



C. Retrofit Cooling Tower Fans with VFDs



This portion of the project will consist of retrofitting the existing cooling tower fans with variable frequency drive (VFD) units.







D. Retrofit Sliding Entry Doors with New Revolving Door at Southeast Entrance to Building 1



This portion of the project will consist of demolition of existing sliding doors at the southeast entrance to building 1 and replacement with new revolving door. All work shall comply with VA specifications and standards.



E. Repair Chilled Water Distribution System





This portion of the project will consist of evaluating, repairing and upgrading the existing secondary chilled water distribution system throughout all buildings on the site (approximately 1,000,000 SF).

Attachments

Files attached to this notice, newest first
File Type Posted
VA-256-10-RP-0337-0004001.PDF PDF
VA-256-10-RP-0337-0004000.doc DOC document
VA-256-10-RP-0337-0003000.docx DOCX document
VA-256-10-RP-0337-0002000.docx DOCX document
VA-256-10-RP-0337-0001000.doc DOC document
VA-256-10-RP-0337-000.docx DOCX document

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity