Electrochemical Detection of Aerosolized Chem/Biothreats – Open Topic
Closed Solicitation Posted
- Solicitation number
- CBD25D-TP001
- Agency
-
Joint PEO Chemical and Biological Defense
Acquisition Support Center, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 541715 Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology)
- More information
Notice details come from DoD SBIR/STTR (DSIP). Updated .
About this opportunity
The Department of the Army Acquisition Support Center's Joint PEO Chemical and Biological Defense seeks electrochemical detection methodologies, AI/ML signal analysis algorithms, and portable electronic platforms for rapid detection of aerosolized chemical and biological threats under DoD STTR Open Topic CBD25D-TP001, with responses due May 21, 2025, a date that has passed as of November 17, 2026. The set-aside is Total Small Business. The topic carries a Chem Bio Defense technology area with a biotechnology focus area and is marked ITAR: No.
The attached topic summary lists performance targets of sensitivity below 1 g/m3, selectivity at 95% accuracy for positive and negative readings, coefficient of variation below 10%, detection in under 30 seconds, and direct integration with mobile platforms. The same summary states that no CMMC level requirement applies. It also describes Phase III as transition to DoD full-scale production, certification, regulatory compliance, scalable manufacturing, and training, with civilian commercialization in law enforcement, border protection, medical, and public health markets.
The topic is part of the FY25.D Release 7 CBD STTR announcement, which the release file summary describes as managed by the Joint Science and Technology Office for Chemical and Biological Defense at the Defense Threat Reduction Agency. The NAICS code is 541715, Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology), and the PSC is AC12, National Defense R&D Services.
Notice text
DoD STTR topic CBD25D-TP001
Component: CBD
Command: CBD
Phase: STTR Phase I
Technology Areas: Chem Bio Defense
Focus Areas: Biotechnology
Keywords: Electrochemical; Sensor; Biothreat; Virus; Bacterial; Opioids; Portable; AI/ML
ITAR: No
Objective:
This STTR Open Topic seeks to develop and integrate innovative electrochemical detection methodologies, AI/ML-driven signal analysis algorithms, and portable electronic platforms capable of rapid, sensitive, and specific detection of aerosolized chem/biothreat species.
Description:
Solid or liquid aerosols containing virus particles, anthrax, fentanyl, or other biothreats may be weaponized (e.g., Moscow Dubrovka Hostage Situation[1]) and pose significant risk to the DoD mission domestically and abroad, threatening Force readiness, installation security, and border security where Soldiers may be deployed.
Current detection methods are often limited by size, cost complexity, and slow response times. For example, laboratory-based analyses are highly accurate but impractical for immediate field use. Existing portable devices (colorimetric strips, ELISA, light scattering) may suffer from interference, leading to false positives or negatives. These portable methods also generally require 3-10 minutes to make a positive detection. Most notably, the analytical sensitivity must be extremely high to detect the presence of aerosols before the threat level exceeds survivability metrics. Thus, there is a critical need for innovative technologies that offer selective (analyte/interferant differentiation), rapid (<30 s), sensitive (<1 µg/m3), and affordable (<$1/sample) detection with a portable formfactor for ease of use for Soldiers. [2]
Electrochemical methods can achieve high sensitivity and selectivity, rapid response times, and are amenable to miniaturization; however, despite significant academic research, a viable platform has yet to be commercialized for these applications. Recently, exciting developments have been reported for single-entity virus and bacterial measurements [3], nanomaterial sorbents [4], electrochemical AI development [5], and instrumental miniaturization [6]. Thus, by researching microenvironment manipulation techniques, incorporating advanced transducer materials, leveraging AI/ML-driven signal analyses, and/or integrating miniaturized electronic platforms, in-field detection of aerosolized biothreats may be possible to enhance Force protection and tactical awareness.
This STTR Open Topic seeks to (1) uncover innovative electrochemical sensing methodologies to overcome the limitations described above, and (2) pair those methodologies with emerging portable electronic platforms and/or AI/ML data analysis algorithms. The focus is on creating portable, reusable devices that provide real-time results with minimal false readings, driven by innovative chemistry or algorithms to quickly provide Soldiers tactical information. This technology would enhance the DoD capabilities for counter-terrorism operations, security screening, and operational awareness. The development also holds significant potential for dual-use applications in law enforcement, homeland security, and public health sectors, representing an important enabler to combat the future pandemics, the opioid crisis, and to protect Soldiers from chem/bioweapons leveraging these compounds.
Phase I:
Demonstrate the feasibility of innovative electrochemical detection methods for relevant chem/biothreat (or analog) aerosols. Conduct laboratory experiments and/or modeling analysis to develop and validate the proposed sensing techniques in solid and/or liquid aerosol media while assessing:
- Sensitivity using limit of detection (LOD) and limit of quantitation (LOQ) in µg/m3
- Selectivity for a target analyte against common interferants or blank aerosols using signal ratio approaches and false positive/negative analyses
- Reproducibility using coefficient of variation (CV) analyses
Also of interest is leveraging empirical or synthetic data to train AI/ML algorithms capable of deconvoluting complex signals related to these metrics. The desired outcome is a proof-of-concept demonstration showing reliable electrochemical detection of aerosol contents in controlled settings, establishing a foundation for component integration and development in Phase II.
Phase II:
Develop and refine a minimally viable integrated component system of the electrochemical detection methodology, the miniaturized electronic platform, and/or the AI/ML-driven signal analysis based on successful Phase I results. The minimally viable system should:
- Achieve high sensitivity (<1 µg/m3) for solid or liquid aerosolized biothreats
- Demonstrate selectivity for target analytes where interferants or blanks represent <10% of the analytical signal and result in >95% accuracy for positive/negative readings at environmentally relevant aerosol concentrations
- Achieve coefficients of variation (CV) <10% for equivalent trials
- Provide rapid detection results in <30 seconds
- Directly integrate sensing methods, electronics, and algorithms with mobile platforms (phone, pad, etc.) with minimal size, weight, power, and cost (SWaP-C)
The component system should undergo extensive testing in simulated field conditions to validate performance. User testing should also be performed with relevant DoD research Centers or partners to generate a feedback cycle for device improvement. The outcome is a minimally viable component system (TRL 5) with directives for prototype assembly and evaluation in Phase III.
Phase III:
PHASE III: Transition the technology for Department of Defense applications, focusing on full-scale production, certification, and integration into military analysis toolkits. Specific tasks include refining the prototype based on field testing feedback, ensuring compliance with regulatory standards, developing scalable manufacturing processes, and establishing training programs/GUIs for DoD end-users.
Commercialization opportunities in civilian markets should also be pursued by adapting the technology for law enforcement, border protection, and public health sectors.
PHASE III DUAL USE APPLICATIONS: Beyond DoD applications, the device could be utilized by the medical professionals for pandemic response, law enforcement for roadside testing and investigations, or customs agencies for border security, enhancing public safety and health responses.
Files
| File | Type | Posted |
|---|---|---|
| CBD25D-TP001.pdf | ||
| CBD_STTR_25D_R7.pdf |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity