Electrical Testing and Inspection - FCI Manchester, KY

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
15B11024Q00000008
Agency
Federal Correctional Institution Manchester Correctional Facilities, Department of Justice
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
334515 Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
PSC
5999 Miscellaneous Electrical And Electronic Components
Place of performance
Manchester, Kentucky 40962, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Federal Bureau of Prisons Federal Correctional Institution in Manchester, Kentucky seeks to award a single contract for preventative maintenance, testing, and inspection of electrical gear at the facility. Services required include secondary injection and contact resistance testing of breakers, insulation resistance and turns ratio testing of transformers, and contact resistance and insulation resistance testing of KV switches. Offerors must also be capable of cleaning, operating, and visually inspecting this equipment. Proposals are due by January 25, 2024. A site visit will be held on January 9, 2024 at 9:00 AM to allow potential offerors to view the equipment. The agency will evaluate proposals based on technical qualifications, past performance, and price.

There is no set-aside designated for this procurement. The primary NAICS code is 238210 and the dominant PSC code is R499. Performance will take place at the Federal Correctional Institution located at 805 Fox Hollow Road in Manchester, Kentucky. The period of performance will be one year with the possibility of four one-year option periods. The place of performance encompasses the entire correctional facility.

Notice text

The Federal Bureau of Prisons (FBOP), Federal Correctional Institution Manchester located at 805 Fox Hollow Road in Manchester, Kentucky intends to make a single award to a responsible entity that will provide all necessary equipment, labor, materials, and incidentals to complete Preventative Maintenance and Inspection to Electrical Gear. The contractor is responsible for preventative maintenance, testing, and inspection of existing medium and low voltage electrical gear.Breakers- Secondary injection where applicable, manually operate breakers 5 times each, contact resistance, check all connections, visual, clean switchgear enclosures. 
Transformers- Insulation resistance, Winding resistance, Turns test ratio, visual and clean enclosure. 
KV Switches- Contact resistance, insulation resistance, clean and lube, verify good blade penetration, check electrical grounding, inspect arc chutes, clean enclosure. 

SITE VISIT SCHEDULED:  1/9/24  9:00 A.M. 

Attachments

Files attached to this notice, newest first
File Type Posted
1449.pdf PDF
SOW.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Electrical Testing and Inspection - FCI Manchester, KY Award Award Notice
Electrical Testing and Inspection - FCI Manchester, KY This notice · Latest solicitation Solicitation
Electrical Preventative Maintenance Testing and Inspection Original Pre-Solicitation