***This requirement is currently UNFUNDED. ***
The 366th Contracting Squadron is seeking a potential source interested in proposing on an acquisition CYC-247 Cyclone Dust Collection System. If your company is able to provide the supplies requested and are interested in this acquisition please submit the following:
1. Point of contact, including a phone number, physical and e-mail address
2. Size status and or SBA certification program of your company
3. Cage Code for your company

See salient characteristics below:


CLIN 0001: 1 Each: Cyclone Dust Extraction & Collection system
Complete installation including setup, wiring to electrical source, complete installation of all ducting, automated gates at saw equipment source and exterior collection system. Entire system must comply with current ACGIH ventilation requirements (ACGIH Industrial Ventilation Manual 26th Edition, Dated 2004) and meet specifications per saw equipment below. Include minimum 1 year warranty on all parts and installation, system test after installation and operational training to user.


- 36" Band Saw: 4" dust port at the base. Pull 350 CFM at the bottom, 550 CFM at the top and a total of 900 CFM for a blade width up to 3 inches (IAW ACGIH ventilation manual pg. 13-163)


- 14" Band Saw: 3" dust port at the base. Pull 350 CFM at the bottom, 550 CFM at the top and a total of 900 CFM for a blade width up to 3 inches (IAW ACGIH ventilation manual pg. 13-163)


- Cabinet Saw (table saw) 12": 4" dust port. Pull 545 CFM at the base and 350 CFM at the guard for a blade up to 16 inches in diameter (IAW ACGIH ventilation manual pg. 13-164)


- Radial Arm Saw 12": Dust port required behind the blade. Pull 500 CFM (450 CFM at the bottom hood and 50 CFM through the flexible hose) and maintain a duct velocity of 4000 FPM (IAW ACGIH ventilation manual pg. 13-1685)


 



System to be installed on exterior NE corner of LRC, bldg 1132, concrete already in place, must enter bldg to woodshop through 10" diameter round opening in brick wall 114" on center above concrete. Power must be 208V, 3 Phase. Power must be pulled through exixting piping to CB Panel and connected.



**This sources sought notice is for information and planning purposes only. It does not constitute a solicitation and is not to be considered as a commitment by the Government. All firms responding to this sources sought notice are advised that their responses to this notice are not a request that will be considered for contract award. **