Construction of a Plant Genetics Research Unit Office and Laboratory located in Columbia, Missouri

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
W912DQ23R4006
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

This solicitation from the Department of the Army Corps of Engineers Engineering District Kansas City seeks the construction of a new approximately 25,000 square foot Plant Genetics Research Unit office and laboratory facility located in Columbia, Missouri. Key requirements for the project include structural CMU and steel construction, membrane roofing, HVAC, electrical, telecommunications, fire protection, sustainable design and LEED Silver certification, comprehensive interior design and fit-outs including casework and equipment for laboratories. Proposals will be evaluated based on a best value trade-off methodology considering both technical solution and price. Deadline for proposals is January 12, 2023.

There is no set-aside designated for this opportunity. The primary NAICS code is 236220 and PSC code S206 for the construction of research and development facilities. The single-story facility is to be constructed on current USDA property near the intersection of Research Park Drive and Carrie Francke Drive in Columbia, Missouri. The solicitation provides instructions on proposal requirements and basis for award to support selection of a contractor to complete the full scope of the approximately $25 million construction project.

Notice text

2 versions

Update #2 · Latest ·

PLANT GENETICS RESEARCH UNIT OFFICE AND LABORATORY COLUMBIA, MISSOURI PREVIOUS PRE-SOLICITATION NOTICE UNDER W912DQ22R4006. Key aspects of this project include but are not limited to; an approximate 25,000 sq ft. new single-story facility shall consist of with structural CMU walls with nominal CMU veneer. Other components include structural steel members, membrane roofing system and campus utilities. HVAC systems will include multiple air handling units, zoned pressurization and multiple VAVs along with exhaust fans and fan coil units. Building service entrance conductors will be copper with type XHHW insulation. The secondary feeders will be 480Y/277V, 3-phase, 4-wire. Telecommunications will be provided through fiber optic and copper. Building will include CCTV, Access Control, Intrusion Detection, Video surveillance systems with applicable cybersecurity requirements. The facility will be completely protected by a hydraulically designed automatic wet pipe sprinkler system in accordance with the IBC. Facility shall follow Guiding principles for Sustainable Federal Buildings and comply with LEED Silver documentation for contractor verified sustainability features. Facility includes full Comprehensive Interior Design to include full Structural interior fit and finishes and Optional Furniture Fixtures and Equipment. Laboratories shall be equipped with modular casework and integral equipment. Site preparation includes demolition of existing minor utilities, clearing/grubbing and site grading. Site improvements include walkways, asphalt and concrete pavements, drainage and storm water control and all necessary support. The work is located at current USDA property near intersection of Research Park Drive and Carrie Francke Drive in Columbia, MO. During solicitation phase, the contractors will provide a technical solution and a price proposal. The contract will be awarded based upon a Best Value Trade-Off process. The solicitation will include a detailed list of Evaluation Factors and will provide instructions for Proposal Requirements and the Basis for Award.

Update #1 ·

PLANT GENETICS RESEARCH UNIT OFFICE AND LABORATORY COLUMBIA, MISSOURI PREVIOUS PRE-SOLICITATION NOTICE UNDER W912DQ22R4006. Key aspects of this project include but are not limited to; an approximate 25,000 sq ft. new single-story facility shall consist of with structural CMU walls with nominal CMU veneer. Other components include structural steel members, membrane roofing system and campus utilities. HVAC systems will include multiple air handling units, zoned pressurization and multiple VAVs along with exhaust fans and fan coil units. Building service entrance conductors will be copper with type XHHW insulation. The secondary feeders will be 480Y/277V, 3-phase, 4-wire. Telecommunications will be provided through fiber optic and copper. Building will include CCTV, Access Control, Intrusion Detection, Video surveillance systems with applicable cybersecurity requirements. The facility will be completely protected by a hydraulically designed automatic wet pipe sprinkler system in accordance with the IBC. Facility shall follow Guiding principles for Sustainable Federal Buildings and comply with LEED Silver documentation for contractor verified sustainability features. Facility includes full Comprehensive Interior Design to include full Structural interior fit and finishes and Optional Furniture Fixtures and Equipment. Laboratories shall be equipped with modular casework and integral equipment. Site preparation includes demolition of existing minor utilities, clearing/grubbing and site grading. Site improvements include walkways, asphalt and concrete pavements, drainage and storm water control and all necessary support. The work is located at current USDA property near intersection of Research Park Drive and Carrie Francke Drive in Columbia, MO. During solicitation phase, the contractors will provide a technical solution and a price proposal. The contract will be awarded based upon a Best Value Trade-Off process. The solicitation will include a detailed list of Evaluation Factors and will provide instructions for Proposal Requirements and the Basis for Award. *Visit 'https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?solNo=W912DQ23R4006' to obtain more details.*

Notice history

Notice Type Posted
Construction of a Plant Genetics Research Unit Office and Laboratory located in Columbia, Missouri Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Veterans Affairs St. Louis Health Care System (VASTLHCS) John Cochran (JC) Hospital in St. Louis, Missouri John Cochran Va Medical Center, 915 N. Grand Boulevardsaint Louis, MO 63103UNITED States 63103 · NAICS 236220 ENDIST Kansas City No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors