DoD SBIR topic AF151-009

Component: USAF

Command: AFCEC

Phase: SBIR Program Phase I Action

Technology Areas: Sensors

Keywords: detection; dirty bomb; gamma ray; neutron; radiation; radioactive

Objective:

Develop an expendable, hand-held or smaller detector system that draws little or no power, quantitatively measures gamma and neutron emissions from radioactive materials and communicates the results wirelessly.

Description:

Theft or improper disposal of radioactive isotopes, both as events to be dealt with by first responders and cleanup crews and as potential payloads for environmental weapons dispersing radioactive isotopes ("dirty bombs”), pose a threat to health and safety. Traditional methods for hot-atom detection amplify and detect electrons dislodged from an air or gas sample by alpha or beta emissions; however, as alpha- and beta-emitting isotopes also emit energetic photons (gamma rays), a capability to detect and characterize gamma and neutron emissions should be sufficient to sense and identify hot isotopes in environmental settings. Troops in the field and civilian first responders need a gamma-and-neutron sensor that that is small and rugged enough for hand use in the field to assess post event contamination, guide and monitor the remediation response, and verify at the conclusion of the remediation process that the area is again habitable. A second, highly desirable application for the same sensing technology—broadcast distribution in a state of protracted deployment, reporting electronically to an action center—places a premium on efficiency of energy consumption and independence from external sources of power. Both devices must be inexpensive enough that they can be expendable, responsive within no more than a few minutes of exposure, and at least 99% accurate in detecting emissions; ability to remain in use for extended periods of time without support or maintenance will be useful in the handheld and necessary for the emplaced unit. To provide a useful level of sensitivity and breadth of surface coverage the device should include a durable portal or other aperture that supports detection across a large solid angle, and its sensitivity to materials of interest and capacity to discriminate among them should be equal to or greater than that of existing technology but at lower life-cycle cost and consuming less or, ideally, no externally supplied power.

Desirable features include that the detecting element be small or transparent and colorless (so the user’s view of the area being interrogated is not obscured) and flexible (to conform to different objects and geometries). The ideal embodiment of the broadcast device would perform an initial screening of results and down select to responses exceeding a set threshold, which would be stored as a readable record of results reported, date, time and GPS location, and which could be transmitted wirelessly, on demand, to a central information management unit to be integrated to generate a map of contamination. It is expected that no government materials, data, equipment or facilities will be provided as part of this contract.

Phase I:

Develop a breadboard prototype detector and demonstrate proof of concept through small-scale testing. Target is to detect and discriminate among seven different radioactive isotopes at two emission rates differing by a factor of 10 or more.

Phase II:

Develop a full-scale prototype and test it in the field against an “authentic” detector. For each of 10 different isotopes and 3 controls agreement between the two systems’ measurements must be within 20%. Deliverables include a 50% design for a manufacturable prototype and a cost analysis for its production.

Phase III:

Design and produce detectors as part of an outer garment or compatible with operation by minimally trained personnel deployed in rugged environments in full-body protective gear & bulky gloves for use in cargo portals & containers, initial screening for contamination, including under salt water.

Files