Communications Headquarters Facility - DMAFB

Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
W912PL26RA011
Agency
Responses due
Not on record
Set-aside
No set-aside

Opportunity facts

Place of performance
Davis-Monthan Air Force Base, 3100 S. Craycroft Road,Tucson, AZ 85707 85707

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Army Corps of Engineers, Engineering District Los Angeles is seeking design-build services for the construction of a 45,025 square foot Communications Squadron headquarters facility at Davis-Monthan Air Force Base. The facility must incorporate a reinforced concrete foundation, concrete slab, structural steel frame, and standing seam metal roof, with portions designed to comply with Intelligence Community Directive 705 criteria and standards. Key requirements include compatibility with Department of Defense and Air Force design standards, incorporation of a 500-kilowatt generator, compliance with DoD antiterrorism and force protection requirements per Unified Facilities Criteria 4-010-01, and the ability to withstand applicable wind loads and seismic effects. The procurement will utilize a one-step best value trade-off methodology, meaning the Government will evaluate proposals based on both technical merit and price, with award going to the contractor offering the greatest overall benefit rather than necessarily the lowest price. The Government will accept proposals that achieve an optimal balance between technical factors and cost considerations as outlined in the forthcoming Request for Proposal.

This is an unrestricted procurement with no set-aside designations, and no incumbent contractor information has been disclosed in this pre-solicitation notice. The pre-solicitation does not specify the award value or budget range for the project. Prospective offerors should anticipate that the formal RFP will provide detailed evaluation criteria, technical specifications, and submission requirements. The scope of work includes all supporting infrastructure such as site improvements, utilities, communications systems, pavements, parking areas, and sidewalks necessary to create a complete, operational facility. Interested contractors should monitor SAM.gov and relevant federal procurement channels for the anticipated RFP release, which would contain specific proposal deadlines and technical evaluation factors.

Notice text

2 versions

Update #2 · Latest ·

This is a design build project to construct a 45,025SF Communications Squadron headquarters facility with reinforced concrete foundation, concrete slab, structural steel frame, standing seam metal roof and exterior. Portions of this facility must be constructed to comply with Intelligence Community Directive 705 criteria and standards. The facility should be compatible with applicable Department of Defense, Air Force, and base design standards. In addition, local materials and construction techniques shall be used where cost effective. The facility must be able to withstand wind loads and seismic effects as prescribed in applicable codes and design guides. The facility will include a 500KW generator which is authorized by the Air Force Manual 32-1062. The project will include all supporting facilities such as site improvements, utilities, communications, pavements, parking, and sidewalks necessary to provide a complete and useable facility. Facilities will be designed as permanent construction in accordance with Department of Defense Unified Facilities Criteria 1-200-01.This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facilities Criteria4-010-01.THIS PROJECT IS AN UNRESTRICTED REQUEST FOR PROPOSAL (RFP), BEST VALUE TRADE-OFF. The procurement method used will be 1-step best value trade-off. Eligible offerors will be required to provide a technical and price proposal for consideration of award. The technical proposal will be evaluated based on the evaluation criteria stated in the RFP. When the U.S. Army Corps of Engineers (USACE) uses a Best Value Trade-Off procurement, it is seeking to award a contract to the contractor that provides the greatest overall benefit in response to the requirement, not necessarily the one with the lowest price. This method allows for a tradeoff between non-cost factors and cost/price, and lets the Government accept a proposal that is not the lowest priced or the highest technically rated to achieve the best value. Evaluation Method: The project will be a negotiated procurement using the Best Value Trade-Off process to ensure a competitive, firm-fixed price contract. The solicitation will be available on or about 16 April 2026. The solicitation and all amendments for this acquisition will be posted on SAM.GOV, http://sam.gov/. It is the responsibility of the offerors to check the designated government point of entry - sam.gov - frequently for any amendments or changes to the solicitation. All Offerors are also advised that this procurement may be delayed, cancelled, or revised at any time during the solicitation, evaluation and/or final award processSubcontracting Goals:? The SDVOSB goal of (5% Subcontract value/3% Contract value) is reflective of the 2024 NDAA, number of SDVOSBs among the possible NAICS code scopes and past performance above? The SDB goal is (8% Subcontract value/5% Contract value) given the high numbers of SDBs within the NAICS codes of possible scopes in addition to SDB past performance below and DFARS 219.705-4.? The WOSB goal is (5% Subcontract value/4% Contract) value given the high numbers of WOSBs within the NAICS codes of possible scopes in addition to WOSB past performance above.? The HUB goal is (1.5% Subcontract value/1% Contract) value given the very low numbers of HUBs within the NAICS codes of possible scopes in addition to the HUB past performance above.? The SB goal is (40% Subcontract value/30% Contract) given the high numbers of SBs within the NAICS codes of possible scopes in addition to the SB past performance above. This SB goal is higher than the DoD recommended goal of 30%

Update #1 ·

This is a design build project to construct a 45,025SF Communications Squadron headquarters facility withreinforced concrete foundation, concrete slab, structural steel frame, standing seam metal roof and exterior. Portions ofthis facility must be constructed to comply with Intelligence Community Directive 705 criteria and standards. The facilityshould be compatible with applicable Department of Defense, Air Force, and base design standards. In addition, localmaterials and construction techniques shall be used where cost effective. The facility must be able to withstand wind loadsand seismic effects as prescribed in applicable codes and design guides. The facility will include a 500KW generator whichis authorized by the Air Force Manual 32-1062. The project will include all supporting facilities such as site improvements,utilities, communications, pavements, parking, and sidewalks necessary to provide a complete and useable facility. Facilitieswill be designed as permanent construction in accordance with Department of Defense Unified Facilities Criteria 1-200-01.This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facilities Criteria4-010-01.THIS PROJECT IS AN UNRESTRICTED REQUEST FOR PROPOSAL (RFP), BEST VALUE TRADE-OFF. Theprocurement method used will be 1-step best value trade-off. Eligible offerors will be required to provide a technical and priceproposal for consideration of award. The technical proposal will be evaluated based on the evaluation criteria stated in theRFP. When the U.S. Army Corps of Engineers (USACE) uses a Best Value Trade-Off procurement, it is seeking to award acontract to the contractor that provides the greatest overall benefit in response to the requirement, not necessarily the onewith the lowest price. This method allows for a tradeoff between non-cost factors and cost/price, and lets the Governmentaccept a proposal that is not the lowest priced or the highest technically rated to achieve the best value. Evaluation Method:The project will be a negotiated procurement using the Best Value Trade-Off process to ensure a competitive, firm-fixed pricecontract. The solicitation will be available on or about 16 April 2026. The solicitation and all amendments for this acquisitionwill be posted on SAM.GOV, http://sam.gov/. It is the responsibility of the offerors to check the designated government pointof entry - sam.gov - frequently for any amendments or changes to the solicitation. All Offerors are also advised that thisprocurement may be delayed, cancelled, or revised at any time during the solicitation, evaluation and/or final award process

Notice history

Notice Type Posted
Communications Headquarters Facility - DMAFB Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
B-21 Field Training Detachment Facility, Dyess AFB-OT Feasibility & Business Feedback NAICS 236220 ENDIST Fort Worth No set-aside
SOLICITATION NOTICE DESIGN-BUILD TO BUDGET (DB2B) Airborne Equipment Parachute Repair Shop, Yuma Proving Ground, Yuma, Arizona Yuma Proving Ground (YPG) in Yuma, Arizona · NAICS 236220 ENDIST Los Angeles Total Small Business
Sources Sought - Construction Repair Building 6413 Secure Space (511669 & 519580) Barksdale AFB Barksdale AFB, Louisiana 71110, United States · NAICS 236220 ENDIST Fort Worth No set-aside
Request for information/sources sought NAICS 236220 ENDIST Albuquerque No set-aside
Request for Lease Proposal (RFLP) Enhanced Use Leasing Project Davis-Monthan Air Force Base, AZ Tucson, Arizona 85707, United States · NAICS 531190 Air Force Installation Contracting Agency No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity