Commercial Grade Dust Collector System
Closed Solicitation Posted
- Solicitation number
- W911S226U4220
- Agency
-
MICC Fort Drum
Mission and Installation Contracting Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 333413 Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing
- PSC
- 5915 Filters And Networks
- Place of performance
- Nwjrcf Accbldg 20000 Alder RDJoint Base Lewis McChord, WA 98433
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum seeks a commercial-grade shaker filter baghouse dust collection system, with proposals due September 7, 2026. The procurement is a Total Small Business set-aside.
Place of performance is Joint Base Lewis-McChord, Washington (20000 Alder Rd). The system must retrofit into existing ductwork from a 2006 Murphy-Adams Shaker Style dust collection system (model MRSE-20-6D) serving a 5,000 square foot facility and support simultaneous operation of multiple high-demand machines including belt sanders, CNC routers, planers, and saws without starving the system of static pressure, while providing 99.9% pure air return into the facility. CFM requirements are based on an attached ductwork schematic. The contractor must include installation, electrical components, and air compression as needed in the total cost, and must secure a Puget Sound Clean Air Agency notice of construction permit. The system must meet federal and Washington State environmental requirements. Delivery and installation are required. NAICS code is 333413, Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing. PSC code is 5915, Filters and Networks. Amendment 0002 extended the solicitation deadline by one week from the original September 7 date to accommodate the permit requirement.
Notice text
3 versions
Update #3 · Latest ·
Amendment 0002. Need to add: must include Puget Sound Clean Air Agency notice of construction permit. Because of this, extending the solicitation for a week. Amended to add set aside code. Shaker filter / baghouse style dust collection system capable of allowing multiple high-demand machines (belt sanders, CNC routers, planers, saws) to run simultaneously without starving the system of static pressure and provide 99.9% pure air return into facility. Must be able to retrofit into ductwork from a 2006 Murphy-Adams Shaker Style dust collection system (model MRSE-20-6D) for a 5,000 square foot facility. Installation, electrical components, and air compression (as needed) requested for inclusion in the total cost. CFM requirements based on attached ductwork schematic. Must meet federal and Washington State environmental requirements. Delivery and installation required.
Update #2 ·
Amended to add set aside code. Shaker filter / baghouse style dust collection system capable of allowing multiple high-demand machines (belt sanders, CNC routers, planers, saws) to run simultaneously without starving the system of static pressure and provide 99.9% pure air return into facility. Must be able to retrofit into ductwork from a 2006 Murphy-Adams Shaker Style dust collection system (model MRSE-20-6D) for a 5,000 square foot facility. Installation, electrical components, and air compression (as needed) requested for inclusion in the total cost. CFM requirements based on attached ductwork schematic. Must meet federal and Washington State environmental requirements. Delivery and installation required.
Update #1 ·
Shaker filter / baghouse style dust collection system capable of allowing multiple high-demand machines (belt sanders, CNC routers, planers, saws) to run simultaneously without starving the system of static pressure and provide 99.9% pure air return into facility. Must be able to retrofit into ductwork from a 2006 Murphy-AdamsShaker Style dust collection system (model MRSE-20-6D) for a 5,000 square foot facility. Installation, electrical components, and air compression (as needed) requested for inclusion in the total cost. CFM requirements based on attached ductwork schematic. Must meet federal and Washington State environmental requirements. Delivery and installation required.
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Construction material | MICC Fort Drum | Total Small Business | |
| Purifier unit, air | Construction and Equipment | HUBZone | |
| Deburring Machine | MICC Fort Drum | Total Small Business | |
| FY27 42SFS CATM Range Cleaning | Air Education and Training Command | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline