Collapsible and Protective Portable Canine Shelter
Closed Solicitation Posted
- Solicitation number
- CBD222-003
- Agency
-
Joint PEO Chemical and Biological Defense
Acquisition Support Center, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 541715 Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology)
- More information
Notice details come from DoD SBIR/STTR (DSIP). Updated .
Notice text
DoD SBIR topic CBD222-003
Component: CBD
Command: CBD
Phase: SBIR Program Phase I Action
Technology Areas: Chem Bio Defense
Focus Areas: General Warfighting Requirements (GWR)
Keywords: Military Working Dog; Canine Protection; Canine Physiology; Canine Kennel; Chemical and Biological Protection
ITAR: No
Objective:
Develop a collapsible, one person-portable, chemical and biological protective kennel with air filtration for rapid deployment to protect Military Working Dogs
Description:
Military Working Dogs (MWDs) have proven to be a vital component in the execution of warfighter missions. From supporting warfighter security to being a force multiplier, MWDs and their handlers are often the first to enter and assess situations where Chemical/Biological (CB) or other threat materials are present. If an area is contaminated or otherwise unsafe due to an imminent CB threat or is operational mobility limited, immediate exfiltration can be delayed. Handlers have access to a wide array of personal protective equipment (PPE), developed, improved and deployed for decades; however, there are very few PPE options for MWDs. Most, if not all, currently fielded protection systems, like the Joint Expeditionary Collective Protection (JECP) Shelters require a significant logistical footprint including electrical access and complex active filtration. For certain critical missions demanding a high degree of maneuverability and general readiness, it is highly desirable to have innovative MWD shelters with much lower logistical requirements and convenience elements such as portability, air filtration and expansion for future requirements. The goal of this SBIR topic is to develop a one person-portable canine shelter addressing the following requirements:
- Deployment: the shelter should be able to be set up in the same time that the handler would be donning an individual CB protective suit.
- Total System Weight: 22 lbs (threshold); 12 lbs (objective). Total system weight includes all components and required elements, exclusive of batteries (if any).
- Deployed Shelter Volume: must be capable of comfortably housing canines up to 75 lbs (threshold) with a range of 60 to 120 lbs (objective).
- Stowed Shelter Volume: 4000 in3 (threshold); 1800 in3 (objective). Shelter volume is independent of any external components.
- Total System Volume (stowed; all components): 5000 in3 (threshold); 2200 in3 (objective).
- Filtration: shelter should be capable of filtering particulates and adsorbing a wide range of chemical warfare agents such as (but not limited too): nerve agents—tabun (GA), sarin (GB), soman (GD), VX; mustard agents—H, HD, L; tear agents— CN, CS, CR, OC; blood agents— hydrogen cyanide (AC), cyanogen chloride (CK), arsine (SA); chlorine, phosgene, chloropicrin (PS), and diphenylchloroarsine (DA). Any required filter elements should be user-exchangeable and commercially available.
- Airflow: shelter shall provide adequate, filtered air to canines both at rest and under exertion, minimum 1.1 cfm/sf (threshold); shelter shall also allow for one-way exhaust of air back into the atmosphere.
- Other Environmental: all components shall be independently operational between 32 and 105 degrees Fahrenheit (threshold) with a wider rage desired; interior of shelter must maintain temperature and humidity within CFR specifications for dog transport (45 – 85 degrees Fahrenheit and 30-70% relative humidity for no more than 4 hours); shelter materials shall be CB resistant/protective.
- Health/Safety: safe to the touch for canine and handler (e.g., no sharp edges, exposed moving parts, and potentially hazardous protruding parts); safe for the sheltered canine (e.g., resistant to scratching/biting, no toxic components, no risk of physiological harm/stress); a system to notify handler of any unexpected risks to the canine are of interest.
- Power: power requirements should be carefully considered to ensure portability; battery operation, DC operation, and hybrid approaches are of interest.
- Backpack transportable by one individual.
- Additional Elements: also of interest, but not required, include systems which provide temperature control/regulation, broader temperature and environmental operational parameters (e.g., radioactivity detection), consideration of health concerns related to animal waste, lighting and multiple stowage/transport options.
Research conducted under this topic must comply with Federal and Department of Defense Regulations, and Public Law (in particular, Animal Welfare Act 4 and amendments) regarding the treatment of dogs.
Phase I:
Design an appropriate Canine Shelter Technology that will meet the requirements outlined above. Threshold and objective quantitative health requirements including physiological, anatomical and behavioral will be defined after consulting with both military and commercial sources. Provide a detailed description of the operation of the system and mechanism of air filtration for canine safety. Identify components and/or develop technical specifications for components that, when integrated, will meet the performance goals. Conduct necessary calculations on the design and performance of the components to demonstrate the feasibility and practicality of the proposed Canine Protective Shelter for maximum efficiency, including mitigation of risks associated with factors limiting system performance and operating in extreme environments in theatre. Demonstrate a prototype system or primary components of a prototype system at TRL 3+.
Phase II:
Optimize and construct working prototypes at TRL 4-5 as designed and configured in Phase I to meet or exceed stated objectives. Conduct laboratory tests to validate all specifications. Conduct field tests if appropriate. Develop final product specification documents that include a list of all system components and their requirements and instructions for field deployment and stowage. In addition, an investigation of potential alternative applications should be conducted in conjunction with a market assessment.
Phase III:
PHASE III: Materials and technology developed under this project could also be integrated into military individual protection equipment and collective protection equipment for the Warfighter. The system would provide real-time chemical protection in a hazardous environment, enabling the Warfighter and canine to have necessary protection.
PHASE III: DUAL USE APPLICATIONS: The system could be introduced into the civilian marketplace along with current civilian CB barrier technologies. The shelter could be incorporated for use in other applications for civilian response in a hazardous chemical environment for both domestic and working animals. The shelter would also be applicable to federal, state and local law enforcement. The temperature and ventilation systems employed in the system could separately be marketed for government and commercial uses.