About this opportunity

Pacific Air Forces 354 CONS is conducting market research to assess vendor capabilities for supplying OEM-compatible water treatment chemicals and field technical services for six coal-fired stoker boilers at Eielson Air Force Base Central Heat and Power Plant, with responses due October 15, 2026. No set-aside is anticipated.

Place of performance is Eielson AFB, interior Alaska. Vendors must deliver exact Nalco and Permatreat brand chemicals—Nalco 8735, Tri-ACT 1820, Nexguard 22310, Permatreat PC-191, and Nalco 1720—compatible with existing base 3D TRASAR infrastructure. Supply logistics require heated, climate-controlled transport and FOB Destination offloading to prevent chemical degradation during sub-zero transit. Vendors must dispatch an authorized technician to Building 6203 within 24 hours of technical notification to address water chemistry anomalies. Automated fluorescence monitoring equipment must maintain 95 percent uptime, and vendors must coordinate pickup and return of reusable chemical containers.

Notice text

The 354 CONS is conducting market research to assess vendor capabilities for supplying water treatment chemicals and field technical services for six (6) coal-fired stoker boilers at the Eielson AFB Central Heat and Power Plant (CHPP).

Brand-Name Chemical Supply: Deliver exact OEM-compatible Nalco and Permatreat water treatment chemicals (Nalco 8735, Tri-ACT 1820, Nexguard 22310, Permatreat PC-191, and Nalco 1720) compatible with existing base 3D TRASAR infrastructure.

  • Extreme Cold-Weather Logistics: Provide heated, climate-controlled transport and offloading (FOB Destination) to interior Alaska to prevent chemicals from freezing or degrading during sub-zero transit.

  • Rapid On-Site Technical Response: Dispatch an authorized technician to Building 6203 within 24 hours of notification to address water chemistry anomalies.

  • Automated Monitoring & Container Management: Maintain automated fluorescence monitoring equipment (95% uptime) and coordinate the pickup and return of reusable chemical containers.