Chlorine Dioxide Machine

Closed Solicitation Posted

Solicitation number
12405B23Q0542
Agency
Southeast Area Field Research Implementation and Information Delivery, Department of Agriculture
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
562910 Remediation Services
PSC
6640 Laboratory Equipment And Supplies
Place of performance
Athens, Georgia 30605, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The US National Poultry Research Center (USNPRC) requires a portable chlorine dioxide decontamination unit for use in HEPA filter decontaminations, which are necessary for research integrity, personnel safety, and filter certification. The unit must be able to be moved easily, connect to various fittings, decontaminate spaces up to 120 cubic feet, generate chlorine dioxide gas using chemical packets, provide a neutralization process, and include an aeration function to reduce decontamination cycle downtime. The unit must also be compatible with the same connections and chemicals as an existing machine on campus.

Products and Services:

  1. Portable chlorine dioxide decontamination unit
  2. Ability to connect to various fittings for decontamination process
  3. Capability to decontaminate spaces up to 120 cubic feet
  4. Generation of chlorine dioxide gas using chemical packets
  5. Neutralization process and aeration function to expedite decontamination process.

Notice text

The Biosafety Officer at US National Poultry Research Center (USNPRC) has the need to purchase a chlorine dioxide decontamination unit to be utilized in HEPA filter decontaminations.  These decontaminations are necessary for research integrity and personnel safety after and between when experiments are conducted and for certification of the filters that serve these spaces.  The required specifications for the chlorine dioxide machine decontamination machine are that it is portable, have the ability to be physically moved from various spaces utilizing a handle and wheels for personnel safety, up and down stairs and utilize the same connections relative to filters that need to be decontaminated and certified and utilize the same chemicals as an existing machine currently on campus.  The machine must have the ability to be connected to various fittings for the decontamination process.  The chlorine dioxide machine must be able to decontaminate small space volumes up to 120 cubic feet. The machine must be able to generate chlorine dioxide gas utilizing chemical packets and provide a neutralization process as well.  This ensures the gas generated is neutralized at the end of the decontamination process.  An aeration function that is included or integrated within this decontamination unit is critical in reducing decontamination cycle downtime to expedite the decontamination process to facilitate research. 

Attachments

Files attached to this notice, newest first
File Type Posted
Chlorine Dioxide Machine Specs.docx DOCX document
Beta Sam Solicitation.docx DOCX document
Clauses and Provisions.docx DOCX document

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity