Chemical Storage Building

Closed Solicitation Posted

Solicitation number
W911S226U3863
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
4525 Camp Hale Rd Fort Drum, NY 13602 13602

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum seeks construction and delivery of a chemical storage building, with proposals due August 27. The procurement is a Total Small Business set-aside.

The building will be delivered to Building P-91, Railroad Street, Fort Drum, NY 13602, with place of performance at 4525 Camp Hale Road, Fort Drum, NY 13602. The NAICS code is 332311, Prefabricated Metal Building and Component Manufacturing; PSC is 5670, Building Components, Prefabricated.

The structure must meet detailed specifications: minimum dimensions of 42 feet length, 8 feet width, and 8 feet 3 inches height; double doors (60 inches by 80 inches) with at least one 36-inch active leaf centered on a 42-foot wall; and a 1,200-gallon minimum sump for spill containment. Fire-rating requirements include walls tested by Intertek for a minimum 4-hour rating and a roof tested for a minimum 3-hour rating. Electrical systems must include a 12-space, 100-amp NEMA 3R main breaker panel (120V/240V), two Class 1, Division 2 explosion-proof LED light fixtures with interior switch, and a dust/vapor-resistant exterior light with photocell outside the hazard zone. An explosion-proof exhaust system rated for 335 CFM or higher, compliant with all NFPA/UFC codes, must include an indicator light and emergency shut-off switch. Interior furnishings include three-tier, 5-foot-long shelves (14 inches deep with 2-inch lip), a non-perforated skid-resistant steel ramp (minimum 52 inches wide by 72 inches long), and a grounding kit with 8-foot ground rod, 10 feet of cable, and clamp. Three 10-pound ABC dry chemical fire extinguishers must be included: two mounted inside flanking the door and one outside in a weatherproof cabinet.

Notice text

The chemical storage building must meet several specifications for construction, safety, and utility. The required minimum dimensions are 42 feet in length, 8 feet in width, and 8 feet 3 inches in height. Access shall be provided by a 60-inch by 80-inch set of double doors, with at least one 36-inch active leaf, centered on one of the 42-foot walls and secured with a padlock-compatible handle. For spill containment, the building must include a sump with a minimum capacity of 1200 gallons.The structure must feature a robust fire-rated design, with walls tested by Intertek for a minimum 4-hour rating and a roof tested for a minimum 3-hour rating. Electrical specifications include a 12-space, 100-amp NEMA 3R main breaker panel (120V/240V), two Class 1, Division 2 explosion-proof LED light fixtures with a switch for the interior, and a dust/vapor-resistant exterior light with a photocell installed outside the hazard zone. Ventilation will be handled by an explosion-proof exhaust system rated for 335 CFM or higher, suitable for petroleum-based storage and compliant with all NFPA/UFC codes, complete with an indicator light and an emergency shut-off switch.For safety and functionality, the building shall be equipped with a grounding kit including an 8-foot ground rod, 10 feet of cable, and a clamp. The interior will be furnished with three-tier, 5-foot-long shelves that are 14 inches deep with a 2-inch lip. A non-perforated, skid-resistant steel ramp, measuring at least 52 inches wide by 72 inches long, must be included. Additionally, the unit shall come with three 10-pound ABC dry chemical fire extinguishers: two installed inside on either side of the door, and one mounted outside in a weatherproof cabinet. The completed chemical storage building is to be delivered to Building P-91, Railroad Street, Fort Drum, NY 13602.

Similar open opportunities

Opportunity Agency Set-aside Responses due
Construction material PBO, 2/75 Ranger RegimentBLDG 3463, 3rd Division Dr./Mastin Ave.Jblm, WA 98433 98433 · NAICS 327390 MICC Fort Drum Total Small Business
Electrically Heated Tank U.S Army Yuma Proving Ground 85365 · NAICS 333248 MICC Fort Drum Total Small Business
FY23-28 General Construction Services BPA - W911S223S8000 Fort Drum, New York 13602, United States · NAICS 236220 MICC Fort Drum HUBZone
Blanket Purchase Agreement Porta John Services Fort Drum, New York 13602, United States · NAICS 562991 MICC Fort Drum Total Small Business
ISO Container Repair- Fort Drum Fort Drum, New York, United States · NAICS 811310 MICC Fort Drum Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity