Chemical Storage Building
Closed Solicitation Posted
- Solicitation number
- W911S226U3863
- Agency
-
MICC Fort Drum
Mission and Installation Contracting Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 332311 Prefabricated Metal Building and Component Manufacturing
- PSC
- 5670 Building Components, Prefabricated
- Place of performance
- 4525 Camp Hale Rd Fort Drum, NY 13602 13602
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum seeks construction and delivery of a chemical storage building, with proposals due August 27. The procurement is a Total Small Business set-aside.
The building will be delivered to Building P-91, Railroad Street, Fort Drum, NY 13602, with place of performance at 4525 Camp Hale Road, Fort Drum, NY 13602. The NAICS code is 332311, Prefabricated Metal Building and Component Manufacturing; PSC is 5670, Building Components, Prefabricated.
The structure must meet detailed specifications: minimum dimensions of 42 feet length, 8 feet width, and 8 feet 3 inches height; double doors (60 inches by 80 inches) with at least one 36-inch active leaf centered on a 42-foot wall; and a 1,200-gallon minimum sump for spill containment. Fire-rating requirements include walls tested by Intertek for a minimum 4-hour rating and a roof tested for a minimum 3-hour rating. Electrical systems must include a 12-space, 100-amp NEMA 3R main breaker panel (120V/240V), two Class 1, Division 2 explosion-proof LED light fixtures with interior switch, and a dust/vapor-resistant exterior light with photocell outside the hazard zone. An explosion-proof exhaust system rated for 335 CFM or higher, compliant with all NFPA/UFC codes, must include an indicator light and emergency shut-off switch. Interior furnishings include three-tier, 5-foot-long shelves (14 inches deep with 2-inch lip), a non-perforated skid-resistant steel ramp (minimum 52 inches wide by 72 inches long), and a grounding kit with 8-foot ground rod, 10 feet of cable, and clamp. Three 10-pound ABC dry chemical fire extinguishers must be included: two mounted inside flanking the door and one outside in a weatherproof cabinet.
Notice text
The chemical storage building must meet several specifications for construction, safety, and utility. The required minimum dimensions are 42 feet in length, 8 feet in width, and 8 feet 3 inches in height. Access shall be provided by a 60-inch by 80-inch set of double doors, with at least one 36-inch active leaf, centered on one of the 42-foot walls and secured with a padlock-compatible handle. For spill containment, the building must include a sump with a minimum capacity of 1200 gallons.The structure must feature a robust fire-rated design, with walls tested by Intertek for a minimum 4-hour rating and a roof tested for a minimum 3-hour rating. Electrical specifications include a 12-space, 100-amp NEMA 3R main breaker panel (120V/240V), two Class 1, Division 2 explosion-proof LED light fixtures with a switch for the interior, and a dust/vapor-resistant exterior light with a photocell installed outside the hazard zone. Ventilation will be handled by an explosion-proof exhaust system rated for 335 CFM or higher, suitable for petroleum-based storage and compliant with all NFPA/UFC codes, complete with an indicator light and an emergency shut-off switch.For safety and functionality, the building shall be equipped with a grounding kit including an 8-foot ground rod, 10 feet of cable, and a clamp. The interior will be furnished with three-tier, 5-foot-long shelves that are 14 inches deep with a 2-inch lip. A non-perforated, skid-resistant steel ramp, measuring at least 52 inches wide by 72 inches long, must be included. Additionally, the unit shall come with three 10-pound ABC dry chemical fire extinguishers: two installed inside on either side of the door, and one mounted outside in a weatherproof cabinet. The completed chemical storage building is to be delivered to Building P-91, Railroad Street, Fort Drum, NY 13602.
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Construction material | MICC Fort Drum | Total Small Business | |
| Electrically Heated Tank | MICC Fort Drum | Total Small Business | |
| FY23-28 General Construction Services BPA - W911S223S8000 | MICC Fort Drum | HUBZone | |
| Blanket Purchase Agreement Porta John Services | MICC Fort Drum | Total Small Business | |
| ISO Container Repair- Fort Drum | MICC Fort Drum | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity