Cell Padding and Installation

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
W91WRZ-18-Q-0016
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

PSC
Not on record
Place of performance
Guantanamo Bay Cuba, United States

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

This requirement will be re solicited on 23 March 2018 to increase competition.

Update #1 ·

Salient Characteristics
Padded Room for Detainee Behavioral Health

1. Purpose: Padding for a US Government mental health or psychiatric room in a detention medical facility
2. Shipping to 8998 Blount Island Blvd, Jacksonville, FL 32226 (for embarkation to Guantanamo Bay, Cuba)
3. Installation site: US Navy Station, Guantanamo Bay, Cuba
4. Installation date: No earlier than 28 FEB 2018 and no later than 31 MAR 2018
5. Room dimensions: Approximately 7ft-0in x 12ft-4in x 8ft-3in in height
6. Installed on the interior of walls, floor, ceiling, and steel hinged door and door frame
7. Of a unitary or laminated construction to prevent destruction by teeth, hand tearing, small metal objects
8. Seamless construction and installation
9. Installation shall incorporate venting, door slides/splash passage door (for food, items, etc.), door window pane
10. Rated/approved for use in mental health or psychiatric facilities in the United States
11. Color: Natural beige or tan
12. Product depth: Wall Padding 1 inches in depth, at least 1 ½" total thickness with backing
13. Floor and Ceiling Padding ¾ inches in depth, with at least 1 ¼" total thickness
14. Cushioning property to prevent physical injury of patient or detainee
15. Made from nonflammable, non-toxic material
16. Tested in accordance with ASTM E84 with a Class A fire rating
17. Nonconductive foam or similar material
18. Product has acoustic/vibration dampening and cushioning properties
19. Structurally resilient with low compression set and 90 percent memory
20. Compression properties 30 PSI to 70 PSI at 50% modulus
21. Low water absorption, moisture-resistant and fungus-resistant
22. Nonporous, if available, to facilitate cleaning

Files

File Type Posted
RFI_Cell_Padding_and_Installation.pdf PDF
Padded_Room_Salient_Characteristics.pdf PDF

Notice history

Notice Type Posted
Cell Padding and Installation Latest solicitation Solicitation
This notice Original Pre-Solicitation

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors