CBRN Gloves with Improved Tactility and Touch-Screen Capability
Closed Solicitation Posted
- Solicitation number
- CBD203-001
- Agency
-
Joint PEO Chemical and Biological Defense
Acquisition Support Center, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 541715 Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology)
- More information
Notice details come from DoD SBIR/STTR (DSIP). Updated .
Notice text
DoD SBIR topic CBD203-001
Component: CBD
Command: CBD
Phase: SBIR Program Phase I Action
Technology Areas: Chem Bio Defense; Human Systems; Materials
Focus Areas: General Warfighting Requirements (GWR)
Keywords: Barrier Materials; Chem-Bio Protection; Gloves, Durability; Permeation Resistance; Elastic Stretching; Elastic Relaxation; dexterity
ITAR: No
Objective:
Current, state-of-the-art Chemical, Biological, Radioactive, and Nuclear (CBRN) protective gloves are highly protective (butyl rubber) and durable [1], but are bulky and induce an elevated thermal burden when worn for extended periods. The fit, sizing, and physical bulk of gloves is critical to avoid restricting user dexterity, which is needed to perform tasks in high risk environments [2, 3]. The increased thermal burden associated with wear decreases user comfort and acceptance [4]. Additionally, current systems cannot be used while operating capacitive-based touch screen systems that are increasingly necessary in military operations. This topic addresses the technical challenges and innovative solutions needed to create protective, durable, and conformal gloves that can be integrated into novel CBRN protective ensembles while allowing higher tactility and touch-screen capabilities
Description:
Chemical, Biological, Radioactive, and Nuclear (CBRN) protective ensembles provide the first line of defense for personnel exposed to victims and/or materials during assessment, extrication, rescue, triage, decontamination, treatment, site security, crowd management, and force protection operations at incidents involving CBRN agents. Gloves are an integral part of the ensemble that allow users to perform critical tasks. There is a need for gloves that allow for high levels of function, without trade-off between protection and dexterity, tactility, or thermal burden. Commercially available CBRN protective gloves are bulky and not sufficiently conformal or tactile to the wearer. Additionally, these gloves cannot be used with electronic touch-screen systems. This topic solicits the following innovative technology requirements for a CBRN glove.
| Test | Threshold | Objective |
|---|---|---|
| Chemical permeation resistance: NFPA 1994 Class 1 | 20 g/m2 challenge over 1 hours | 20 g/m2 challenge over 6 hours |
| Puncture Resistance: ASTM F1342/F1342M | Puncture resistance of ≥9 N (≥2 lbf) (threshold) | Puncture resistance of ≥15 N (≥3.8 lbf) (objective) |
| Cut Resistance: ASTM F1790 | Blade travel distance of ≥ 20 mm | Blade travel distance of ≥ 20 mm |
| Stretch recovery: ASTM D2594 | 20% stretch, 90% recovery | 20% stretch, 90% recovery |
| Tensile Strength (durability): ASTM D5034 or equivalent test for breaking strength (N or lbf) and Elongation Break (%) | An objective of 90% resistance to break of butyl rubber | An objective resistance to break equal to butyl rubber |
| Conductivity: 4 point probe | N/A | ≥ 10-10 S/cm |
| Moisture vapor transport (MVTR) ASTM E96 | Equal to butyl rubber | An objective of higher MVTR than butyl rubber |
Table 1. Phase I threshold and objectives.
ACRONYMS:
| ASTM | - American Society for Testing and Materials |
| °C | - Degrees Celsius |
| NFPA | - National Fire Protection Association |
| g/m2 | - Grams per meter squared |
| lbf | - Pounds of force |
| N | - Newtons |
| N⋅m | - Newton meters |
| S/cm | - Siemens per centimeter |
Phase I:
Conduct research on novel concepts for Chem-Bio protective glove materials to achieve both conformal, tactical properties and barrier functions. Upon completion of Phase I, samples of the glove material or materials in swatch/sheet form will be made available for independent evaluation of barrier properties, physical properties, and conductivity. The material(s) should meet the threshold goals outlined above (Table 1) and the detailed conditions for testing must be provided to and be approved by the Government Technical Points of Contact (POCs). The threshold level of chemical permeation resistance should be cumulative permeation mass of less than 6 micrograms/cm2 for industrial chemicals, 1.25 micrograms/cm2 for Soman (GD) and 4.0 micrograms/cm2 for distilled mustard (HD) when challenged with 20 grams per meter squared (g/m2) of liquid chemical agent or 1% agent in gas phase [5,6]. An assessment of capability to form or mold materials into gloves will be provided to the Government Technical POCs. In addition, it is highly encouraged that additional physical property testing be performed on the glove material, such as weight (ASTM D3776, option C), stiffness (ASTM D 747) and thickness (ASTM D 1777), and the results sent to the Government Technical POCs. There is no threshold for these values because while they are indicative of glove tactility, which will be measured in Phase II, they are not determinant.
| Test | Threshold | Objective |
|---|---|---|
| Chemical permeation resistance: NFPA 1994 Class 1 | 20 g/m2 challenge over 1 hour | 20 g/m2 challenge over 6 hours |
| Liquid tight integrity: ASTM D5151 | No liquid penetration | No liquid penetration |
| Puncture Resistance: ASTM F1342/F1342M | Puncture resistance of ≥9 N (≥2 lbf) (threshold) | Puncture resistance of ≥15 N (≥3.8 lbf) (objective) |
| Cut Resistance: ASTM F1790 | Blade travel distance of ≥ 20 mm | Blade travel distance of ≥ 20 mm |
| Stretch recovery: ASTM D2594 | 20% stretch, 90% recovery | 20% stretch, 90% recovery |
| Cold Temperature Performance: ASTM D747 | Bending moment of <0.057 N⋅m at an angular deflection of 60° at -25° C. | Bending moment of <0.057 N⋅m at an angular deflection of 60° at -25° C. |
| Flammability Resistance: ASTM F1358 | Afterflame time of ≤2.0 seconds, does not melt or drip | Afterflame time of ≤2.0 seconds, does not melt or drip |
| Moisture vapor transport ASTM E96 | Equal to butyl rubber | MVTR higher than butyl rubber |
| Tensile Strength (durability): ASTM D5034 or equivalent test for breaking strength (N or lbf) and Elongation Break (%) | An objective of 90% resistance to break of butyl rubber | An objective of resistance to break equal to butyl rubber |
| Conductivity: 4 point probe | ≥ 10-10 S/cm at fingertip region | ≥ 10-10 S/cm, entire glove |
| Glove hand function: ASTM F2010/F2010M | Average % increase over barehanded control <300% | Average % increase over barehanded control <300% |
Table 2. Phase II thresholds and objectives.
Phase II:
Conduct development and assessment of forming or molding the materials into gloves and system level assessment for liquid tight integrity. Further improvements in the material properties should be made to reach as high of a value as possible, near the objectives for permeation (NFPA 1994 Class 1), stretch (20%), and durability resistance to break (90% of butyl rubber), outlined above (Table 2). The threshold level of chemical permeation resistance should be cumulative permeation mass of less than 6 micrograms/cm2 for industrial chemicals, 1.25 micrograms/cm2 for Soman, and 4.0 micrograms/cm2 for distilled mustard when challenged with 20 grams per meter squared (g/m2) of liquid chemical agent or 1% chemical agent in the gas phase. Additional testing such as viral penetration (ASTM F1671) tests are encouraged, with the results sent to the Government Technical POCs. There is no threshold for performance against viral penetration for Phase II performance or NFPA 1994 Class 1 gloves, and results will not be determinant. However, viral testing is required for both NFPA 1994 Class 2 and 3 gloves, and the result may be considered for Phase III Dual Use Applications. The detailed conditions for testing must be provided to and approved by the Government Technical POCs. With approval by the Government Technical POCs, gloves will be integrated into CBRN protective ensembles and system level testing will be completed in the second half of Phase II. User acceptability, form, fit, function, capability on resistive and capacitive touchscreen, thermal burden, thermal and evaporative resistance will be assessed and considered. Upon completion of Phase II, molded samples of the glove, material swatches of the improved upon material(s), and a complete cost analysis for glove production will have been provided to the Government Technical POCs.
Phase III:
PHASE III: The gloves demonstrated in Phase II will be commercialized for production and integration into CBRN protective ensembles. The Government Technical POCs will be available to advise on possible partners and paths forward in both government and industry, with an end goal to deliver glove prototypes able to integrate into an appropriate Chem-Bio ensemble for the intended end-user.
PHASE III DUAL USE APPLICATIONS: First responder and anti-terrorism personnel would also benefit from the use of improved protective gloves that are more conformal, allowing for improved dexterity, tactility and comfort, with touch screen capability. The barrier material can be used not only in protective gloves, but also in other formed/molded applications such as protective socks.
Files
| File | Type | Posted |
|---|---|---|
| CBD203-001.pdf |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity