Solicitation Number: NRMJ20002301028SML

Notice Type: Sources Sought Synopsis

Title: Campbell Scientific HygroVUE10 Temperature/RH Probes and Accessories

Response Date: July 10, 2023

This is a SOURCES SOUGHT SYNOPSIS and is not a pre-solicitation announcement. The purpose of this Market Research and Sources Sought Notice is to gain knowledge of potential qualified U.S. Domestic businesses, which could include Small Business, HUBZone, 8(a), Service Disabled Veteran Owned, Women Owned Small Business firms and even Large Businesses. Responses to this Sources Sought Synopsis will be used by the Government in making appropriate acquisition decisions.

The National Oceanic and Atmospheric Administration (NOAA), Oceanic and Atmospheric Research (OAR), Earth Systems Research Laboratories (ESRL), Physical Sciences Laboratory (PSL) is currently maintaining a network of meteorological weather monitoring systems in the state of California for the California Department of Water Resources (DWR) and other projects. A critical component of these systems is the temperature/humidity probe that records constant temperature and humidity readings for inclusion to the datalogger that is monitoring weather at each site. The current temperature/humidity probes are manufactured by Campbell Scientific, and the PSL is in need of replacements that are compatible in all aspects (form, fit, and function).

INTENDED USE/PURPOSE:

The HygroVUE10 offers a combined temperature and relative humidity element in an advanced digital sensor that is ideal for weather networks. The electronics within the sensor provide accurate measurements, and the sensor is easy to use. The digital SDI-12 output allows a simple connection and measurement by many data logging systems. The sensor housing is designed to withstand permanent exposure to various weather conditions and to fit inside a range of radiation shields (including compact shields). A temperature/relative humidity sensor like the Campbell Scientific HygroVUE10 is required to meet the technical specifications and provide the level of accuracy needed for the PSL’s tolerances.

SPECIAL REQUIREMENTS/ESSENTIAL SALIENT FEATURES:

SPECIFICATIONS

Sensing Element SHT35 modified by Campbell

Scientific

Communication Standard SDI-12 V1.4 (responds to a subset

of commands)

Supply Voltage 7 to 28 Vdc

EMC Compliance Tested and conforms to

IEC61326:2013.

Standard Operating

Temperature Range

-40° to +70°C

Main Housing Material UV stable, white PET-P

Electronics Sealing

Classification

IP67

Sensor Protection Outer glass-filled polypropylene

cap fitted with a stainless-steel

mesh dust filter with nominal pore

size of < 30 μm. The sensor

element has a PTFE protective film

with a filtration efficiency of >

99.99% for particles of 200 nm or

larger size.

Sensor Connector M12, male, 4-pole, A-coded

Cable Polyurethane sheathed, screened

cable, nominal diameter 4.8 mm

(0.19 in.)

Field-Replaceable Chip or

Recalibrate

Field-replaceable chip

Sensor Cap Diameter 12.5 mm (0.5 in.)

Body Diameter at

Connector

18 mm (0.7 in.)

Length 180 mm (7.1 in.) without cable

fitted

Sensor Body Weight 50 g (1.8 oz)

Weight 250 g (8.8 oz) with 5 m (16.4 ft)

cable

RELATIVE HUMIDITY

Measurement Range 0 to 100% RH

Accuracy ±2% (at 25°C, over the range 80

to 100% RH)

-NOTE- The accuracy figures

quoted are the 95% confidence

limits relative to factory

standards.

±1.5% (at 25°C, over the range 0

to 80% RH)

Short-Term Hysteresis < ±1% RH

Additional Errors at Other

Temperatures

< ±1% RH (over -40° to +60°C)

Long-Term Stability ±0.5% per year (maximum drift in

clean air conditions)

Reported Resolution 0.001% RH

Repeatability 0.05% RH (3σ noise level)

Response Time with Filter < 20 s (63% response time in still

air)

AIR TEMPERATURE

Measurement Range -40°C to +70°C

-NOTE- The accuracy figures quoted are

the 95% confidence limits relative

to factory standards.

Accuracy ±0.1°C (over the range 20 to

60°C)

±0.2°C (over the range -40 to

+70°C)

Long-Term Drift < 0.03°C per year

Reported Resolution 0.001°C

Repeatability 0.04°C (3σ noise level)

Response Time with Filter < 130 s (63% response time in air

moving at 1 m/s)

Calibration Traceability NIST and NPL standards

MAXIMUM CURRENT DRAIN

Quiescent 50 μA

During Measurement 0.6 mA (takes 0.5 s)

DELIVERY SCHEDULE:

Deliver by September 30, 2023.

The North American Industry Classification Code (NAICS) is 344513 with a size standard of 750 employees.

Interested firms shall provide, in writing, a brief narrative (no more than 3 pages in length) and documentation to support your firm’s capability and experience meeting the requirements herein and include your firm’s name, address, point of contact, telephone number, UEID Number, CCR CAGE Number, business type and size (i.e., small, large, non-profit, educational, etc.). Any response that does not include this information will not be considered. The Government will review your response to determine if your firm has the experience, knowledge and capability to provide the items as specified above.

This request for information does not constitute a commitment, implied or otherwise, that a procurement action will be issued. Nor does this request for information constitute a commitment, implied or otherwise, that any procurement action may be issued for the Government’s requirements.

No entitlement to payment of direct or indirect costs or charges by the Government will arise because of the submission of contractor’s information. The Government shall not be liable for or suffer any consequential damages for proprietary information not properly identified. Proprietary information will be safeguarded in accordance with the applicable Government regulations.

All contractors doing business with the Government are required to be registered and active with the System for Award Management (SAM) website.

NOTE: THIS SYNOPSIS IS NOT CONSIDERED A REQUEST FOR PROPOSAL BUT A REQUEST FOR INFORMATION ONLY. No solicitation document is available. No contract will be awarded based on responses received to this notice.

Notice history

Notice Type Posted
Campbell Scientific HygroVUE Temperature/RH Probes and Accessories Latest special notice Special Notice
This notice Original Pre-Solicitation

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors