BPA LAB Equipment Sebia
Award Notice Posted
- Solicitation number
- VA26317Q1097
- Agency
-
Veterans Integrated Service Network 23
Veterans Health Administration, Department of Veterans Affairs
- Awarded
- to Sebia, Inc.
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- VA263-17-A-0073 Federal contract award
- PSC
- Not on record
Notice details come from SAM.gov. Updated .
Notice text
LIMITED SOURCES JUSTIFICATION
ORDER >$150,000
FAR PART 8.405-6
Acquisition Plan Action ID:__VA263-17-AP-6777______
This acquisition is conducted under the authority of the Multiple Award Schedule Program. The material
or service listed in par. 3 below is sole source, therefore, consideration of the number of contractors
required by FAR Subpart 8.4 Federal Supply Schedules, is precluded for the reasons indicated below.
Restricted to the following source: Provide original manufacturer s name for material or contractor s
name for service. (If a sole source manufacturer distributes via dealers, ALSO provide dealer
information.)
Manufacturer/Contractor: Sebia Inc
Mfgr/Contractor Address: 705 Corporate Dr, Norcross GA 30093
Dealer/Rep address/phone number: 800-835-6497
The requested material or service represents the minimum requirements of the Government.
(1) AGENCY AND CONTRACTING ACTIVITY: Department of Veterans Affairs
NCO 23 Contracting Activity________
St Cloud VA Health Care System_____
4801 Veterans Drive
St Cloud MN 56303
VISN: 23
(2) NATURE AND/OR DESCRIPTION OF ACTION BEING APPROVED
Sole Source procurement of Capillarys 2 Flex Pierce , Sebia Hydrasys 2 with built-in scanner.
Capillary Ion Phoresis and Immunotyping instrumentation (Capillarys 2 Flex Pierce) and confirmation
testing instrumentation (Hydrasys 2) to be utilized by the Immunology and Special Hematology
laboratories for patient testing.
(3) (a) A DESCRIPTION OF THE SUPPLIES OR SERVICES REQUIRED TO MEET THE AGENCY S NEED:
The Immunology laboratory is currently utilizing the Sebia Minicap analyzer to perform
electrophoresis testing on serum patient samples using the Capillary Ion Phoresis methodology. The
Immunology laboratory also utilizes Sebia s Hydrasys 2 to perform immunofixations of serum and
urine patient samples. Both of these analyzers are on a cost per test (Reagent Rental) contract.
Sebia has manufactured a new instrument, called the Capillarys 2 Flex Pierce, using the same
methodology (Capillary Ion Phoresis) as the Minicap, which can now automate urine samples for
electrophoresis. It also uses new technology (Immunotyping) to perform immunofixations on serum
and urine, automating the identification of abnormal monoclonal proteins which is now performed
on the Hydrasys 2 and is very labor intensive. Additionally, it can analyze whole blood by this
method, so samples for hemoglobin electrophoresis could be run on the Capillarys 2 Flex Pierce
(C2FP).
(b) ESTIMATED DOLLAR VALUE: $461,106.84
(c) REQUIRED DELIVERY DATE: 10/1/2017
(4) IDENTIFICATION OF THE JUSTIFICATION RATIONALE (SEE FAR 8.405-6), AND IF APPLICABLE, A
DEMONSTRATION OF THE PROPOSED CONTRACTOR S UNIQUE QUALIFICATIONS TO PROVIDE THE
REQUIRED SUPPLY OR SERVICE. (CHECK ALL THAT APPLY AND COMPLETE)
Specific characteristics of the material or service that limit the availability to a sole source
(unique features, function of the item, etc.). Describe in detail why only this suggested source can
furnish the requirements to the exclusion of other sources.
Sebia is the only manufacturer which offers FDA approved testing on serum, urine and hemoglobin
specimens by Capillary Ion Phoresis an Immunofixation within the U.S. Its operating system meets
VA s government mandate of Windows 7 or higher. We are requesting a cost per test agreement
with Sebia for one Capillarys 2 Flex Pierce analyzer and one Hydrasys 2 analyzer to be used by the
Immunology and Special Hematology laboratories
The size of the instrument is also important as there is limited bench space. The
dimensions of the instrument cannot be larger than 37 (L) x 25 (W) x 17 (H) inches
(5) DESCRIBE WHY YOU BELIEVE THE ORDER REPRESENTS THE BEST VALUE CONSISTENT WITH FAR 8.4
TO AID THE CONTRACTING OFFICER IN MAKING THIS BEST VALUE DETERMINATION:
Prices are considered fair and reasonable under FAR part 8.
(6) DESCRIBE THE MARKET RESEARCH CONDUCTED AMONG SCHEDULE HOLDERS AND THE RESULTS
OR A STATEMENT OF THE REASON MARKET RESEARCH WAS NOT CONDUCTED:
Market research was conducted and no vendors were found on GSA that can provide the services
needed. A search was also conducted on Vetbiz and no SDVOSB s or VOSB s were found.
(7) ANY OTHER FACTS SUPPORTING THE JUSTIFICATION:
None
(8) A STATEMENT OF THE ACTIONS, IF ANY, THE AGENCY MAY TAKE TO REMOVE OR OVERCOME ANY
BARRIERS THAT LED TO THE RESTRICTED CONSIDERATION BEFORE ANY SUBSEQUENT ACQUISITION
FOR THE SUPPLIES OR SERVICES IS MADE:
None
(9) REQUIREMENTS CERTIFICATION: I certify that the requirement outlined in this justification is a
Bona Fide Need of the Department of Veterans Affairs and that the supporting data under my
cognizance, which are included in the justification, are accurate and complete to the best of my
knowledge. I understand that processing of this limited sources justification restricts consideration of
Federal Supply Schedule contractors to fewer than the number required by FAR Subpart 8.4. (This
signature is the requestor s supervisor, fund control point official, chief of service or someone with
responsibility and accountability.)
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity