BONNET CARRE SPILLWAY STRUCTURE GRATING SUPPLY CONTRACT St. Charles Parish, LA

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
W912P826QA032
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Norco, Louisiana, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Army Corps of Engineers, New Orleans District, seeks supply of hot-dipped galvanized welded bar grating panels and grating clips for the Bonnet Carre Spillway in St. Charles Parish, Louisiana, with proposals due September 18, 2026. The procurement is set aside for Women-Owned Small Businesses (WOSB), and Amendment 0001, effective August 28, 2026, changes grating panel width requirements from 27-5/8 inches to 27-1/2 inches for line items 0001 and 0002.

Delivery is to the Bonnet Carre Spillway project maintenance yard at 16302 River Road, Norco, Louisiana 70079. The contract requires 70 units of serrated, non-banded galvanized welded bar grating panels with 1-1/4" x 3/16" (19-W-4) bar dimensions in both 20-foot and 24-foot spans at 27-1/2 inches wide, and 1,000 units of hot-dipped galvanized G-Type grating clips with adequate depth to secure the 1-1/4" depth grating panels. All materials must be delivered by December 30, 2026, within 90 days of contract award, with proper cribbing, boxing, and palleting to prevent damage. A 48-hour advance notification is required prior to delivery.

This is a firm fixed-price Request for Quote with FOB Destination pricing; the contractor bears all transportation costs. The NAICS code is 332323, Ornamental and Architectural Metal Work Manufacturing; PSC is 5670, Building Components, Prefabricated. Quotes are submitted by email to Leann Thornton at leann.r.thornton@usace.army.mil. The contracting officer is Katherine Vounts; John Fogarty serves as the delivery point of contact.

Notice text

2 versions

Update #2 · Latest ·

Amendment 0001 hereby changes the width requirements in line items 0001 and 0002 from 27-5/8" to 27-1/2".

Submit quotes via email to Leann Thornton; Leann.R.Thornton@usace.army.mil

Update #1 ·

The contractor shall provide all materials for Bonnet Carre Spillway Structure Grating as outlined in the Bidding Schedule and Material & Requirements Paragraphs. The contractor is responsible for purchasing and delivery of all materials to the Bonnet Carre Spillway's project maintenance yard (16302 River Rd., Norco, LA).

a. Furnish 24 foot long (spans) and 20 foot long (spans) of hot dipped galvanized welded bar grating walkway panels in the quantities indicated in the bidding schedule. The galvanized welded bar grating shall be serrated, non-banded with bar dimensions of 1-1/4" x 3/16" (19-W-4). Grating panel widths shall be 27-5/8 inches wide.

b. Furnish 1,000 hot dipped galvanized "G-Type" grating clips with adequate depth to secure the 1-1/4" depth grating panels.

Submit quotes via email to Leann Thornton; Leann.R.Thornton@usace.army.mil

Files

Notice history

Notice Type Posted
BONNET CARRE SPILLWAY STRUCTURE GRATING SUPPLY CONTRACT St. Charles Parish, LA Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Sources Sought for Calcaiseu River Saltwater Barrier FRP Tainter Gate NAICS 326199 ENDIST New Orleans No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity