Boiler Descaling (U. S. Military Academy)
Closed Pre-Solicitation Posted
Not the latest version. See the latest special notice from .
- Solicitation number
- W911SDBOILER
- Agency
-
MICC West Point
Mission and Installation Contracting Command, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- Not on record
- Place of performance
- ACA, United States Military Academy Directorate of Contracting, Attn: Sfca-NR-WP, 681 Hardee Place West Point NY 10996
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
Note that the Solicitation for this procurement has been issued on the Army Single Face to Industry (ASFI) website at https://acquisition.army.mil under Solicitation Number W911SD07R0026. A Site Visit will be held at the U.S. Military Academy at 10 AM (EDT) on Thursday, 17 May 2007, and the Solicitation closes at 4:30 PM (EDT)on 23 May 2007. This procurement is unrestricted. The anticipated dollar magnitude of this procurement is between $25,000 and $100,000.
Update #1 ·
Seeking qualifications of vendors capable of providing High-Pressure Descaling of five (5) Boilers located at the U.S. Military Academy, West Point, NY. Three (3) Boilers at the Central Power Plant are B&W; two (2) 125,000 lbs/hr and one (1) 60,000 lbs/hr. The remaining two (2) Boilers at the Laundry Boiler Plant are Bigelow (ca. 1950), 40,000 lbs/hr. ------------------------------------------------------------------------------------ Contractor Shall Provide: " Have at a minimum, 400 horsepower triplex piston water jet pump " Be able to provide 15,000 psi at 30 GPM " N2 gas pressure regulator to set and maintain pressure and flows " 15,000 20,000 psi hoses, flexible lances, and fittings " 360 degree rotary nozzles for complete ID coverage of tubes " All materials, labor and supervision to complete work " Positive communications (headsets) between personnel " All confined space monitoring " All air moving equipment for ventilation of boilers " All fuel for equipment " Insurance documentation " Experienced crew and supervision with history and references for this type work Government shall provide: " Adequate water supply, 50 gpm @ 50 psi minimum " Access to boiler drums " Removal of boiler internals, to include baffles " 110v electrical power " Effluent discharge to drain " Shower and bathroom facilities SCOPE: Boilers to be cleaned are Boilers #1, 2 & 3 at the Central Power Plant bldg 604, and Boilers #1 & 2 at the Laundry Boiler Plant bldg 845. Boilers #1 & 2 at the Central Power Plant and Boilers #1 & 2 at the Laundry Boiler Plant shall be cleaned during the p lant shutdown the first 2 weeks in June 2007. Boiler #3 at the Central Power Plant shall be cleaned in early fall 2007, either in September or October depending on availability. All work shall be completed during the designated and agreed upon time windows as not to interrupt mission requirements. Boilers #1&2 at bldg 604 have 989 tubes up to 2 inch OD and boiler #3 has 1310 tubes up to 2 inch OD. Boilers #1&2 at 845 have approximately 1000 tubes up to 2 inch OD Each tube shall be given 2 passes with the high pressure lance. Flow rates and pressure adjustments shall be sufficient that all material is removed from the inside of the boiler tubes, this shall be verified by the COR with government owned portable camer a equipment to transverse the tubes. Upon completion, COR shall randomly inspect as many tubes as necessary to ensure satisfactory cleaning. Government personnel shall install all internals, baffle plates and restore the boiler to operational status. Cost for completion of all 5 boilers to include mobilization, demobilization, set-up, tear down, onsite production, fuel, per diem, and consumables. ------------------------------------------------------------------------------------ Interested parties are asked to provide a brief statement of qualifications to perform this contract, including (a) size of business and all applicable designations (e.g., small business, large business, 8(a), HUBZone, service-disabled veteran-owned small business, woman-owned small business, etc.), (b) geographical location of business, (c) statement as to whether the interested party has made prior sales to or performed prior work/services at the U.S. Military Academy and (d) statement as to whether the i nterested party is currently registered in the Central Contractor Registration (CCR) and Online Representations & Certifications (ORCA) websites.
Notice history
| Notice | Type | Posted |
|---|---|---|
| Removal replacement and programming of Oxygen Sensors for Boiler 1 &2 in the Central Power Plant. | Special Notice | |
| Boiler Rental -- US Military Academy West Point NY 10996 | Pre-Solicitation | |
| This notice | Pre-Solicitation |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity