Big Bend Powerhouse Elevator No. 2 Rehab

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
W9128F24R0023
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Fort Thompson, South Dakota 57339, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army Corps of Engineers Engineering District Omaha is seeking a contractor to provide rehabilitation services for the Big Bend Powerhouse Elevator No. 2. The work will involve the demolition and replacement of various elevator components, including the equipment, controls, hoist mechanism, and hoisting system, in order to bring the elevator system up to code. Key requirements include the reuse of the existing elevator cab and five landing doors, the replacement of the existing elevator door on the cab, and the separate enclosure of the machine room and elevator shaft with a 2-hour fire-rated wall. The contract will also require the handling of potential hazardous materials, such as lead and asbestos.

This procurement is set aside for small businesses. The incumbent or current contractor is not specified. The anticipated award value or budget range is not provided. The solicitation is currently in the pre-solicitation phase, with a due date for proposals of June 30, 2024.

Notice text

3 versions

Update #3 · Latest ·

Solicitation will be posted on or around 28 May 2024.

Work will include demolition and replacement of various items including but not limited to elevator equipment, controls, hoist mechanism, hoisting system, and incidental related work. This will include bringing the elevator system up to code to the greatest extent possible. The existing elevator cab and the five existing elevator landing doors will be reused, while the existing elevator door on the cab will be replaced. The machine room and elevator shaft need to be separately enclosed with a 2-hour fire rated wall.

For potential hazardous work there is lead and there is the presence of asbestos/asbestos dust in the wiring, possibly in the machine room door, elevator brake shoes, rough black coating on the outside of the car, and mats hanging on the inside of the car. The interior doors of the elevator tested positive for lead primer via a 3M Instant Test kit.

Update #2 ·

Solicitation will be posted on or around 21 May 2024.

Work will include demolition and replacement of various items including but not limited to elevator equipment, controls, hoist mechanism, hoisting system, and incidental related work. This will include bringing the elevator system up to code to the greatest extent possible. The existing elevator cab and the five existing elevator landing doors will be reused, while the existing elevator door on the cab will be replaced. The machine room and elevator shaft need to be separately enclosed with a 2-hour fire rated wall.

For potential hazardous work there is lead and there is the presence of asbestos/asbestos dust in the wiring, possibly in the machine room door, elevator brake shoes, rough black coating on the outside of the car, and mats hanging on the inside of the car. The interior doors of the elevator tested positive for lead primer via a 3M Instant Test kit.

Update #1 ·

Work will include demolition and replacement of various items including but not limited to elevator equipment, controls, hoist mechanism, hoisting system, and incidental related work. This will include bringing the elevator system up to code to the greatest extent possible. The existing elevator cab and the five existing elevator landing doors will be reused, while the existing elevator door on the cab will be replaced. The machine room and elevator shaft need to be separately enclosed with a 2-hour fire rated wall.

For potential hazardous work there is lead and there is the presence of asbestos/asbestos dust in the wiring, possibly in the machine room door, elevator brake shoes, rough black coating on the outside of the car, and mats hanging on the inside of the car. The interior doors of the elevator tested positive for lead primer via a 3M Instant Test kit.

Notice history

Notice Type Posted
Big Bend Powerhouse Elevator No. 2 Rehab Award Award Notice
Big Bend Powerhouse Elevator No. 2 Rehab Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Bonneville Powerhouse II Unwatering Pump Replacement United States · NAICS 237990 ENDIST Portland Total Small Business
Replace Elevators at FDC Miami Miami, Florida 33132, United States · NAICS 238290 BOP Field Acquisition Office Total Small Business
Elevator Repair and Maintenance Support Services Fort Huachuca, Arizona 85613, United States · NAICS 811310 ACC Aberdeen Proving Ground Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors