B533-- Wastewater Lab Analysis / New Jersey Licensed Operator

Closed Pre-Solicitation Posted

Solicitation number
36C24226Q0186
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
221320 Sewage Treatment Facilities
Place of performance
VA New Jersey Healthcare System Lyons Campus Lyons, New Jersey 07939, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Integrated Service Network 2 is conducting market research through this Sources Sought Notice to identify potential contractors capable of providing a Full-Time S3/C1 Licensed Operator in Charge (LOIC) for the wastewater treatment plant at the VA New Jersey Healthcare System Lyons Campus. The primary requirement is to secure a New Jersey Department of Environmental Protection-certified licensed operator to manage and operate the facility's wastewater treatment processes in compliance with state regulations. Key qualifications include proper certification as an S3/C1 Licensed Operator and demonstrated capability to operate an extended aeration activated sludge system with associated treatment equipment including aeration tanks, clarifiers, sand filters, copper removal systems, and UV disinfection units. Interested contractors must submit their responses to natalie.acevedo@va.gov by December 10, 2025, at 10:00 AM EST, providing company contact information, a brief capability statement, and attestation of proper certification. The evaluation will focus solely on determining the appropriate acquisition strategy and ensuring adequate competition among potential service providers through verification on the SBA website; this notice is for market research purposes only and does not constitute a formal solicitation or commitment by the Government.

This procurement carries no set-aside designation, and no incumbent contractor information is provided in the notice. The wastewater treatment facility serves approximately 1,800 patients, staff, and visitors with a design capacity ranging from 200,000 to 1,000,000 gallons per day, though current operational flow is estimated at 50,000 to 80,000 gallons per day. No award value or budget range is specified in this pre-solicitation phase, as this notice is strictly for market research and capability identification. The solicitation number is 36C24226Q0186, classified under NAICS code 221320 (Sewage Treatment Facilities) and PSC B533 (Special Studies/Analysis—Water Quality). Respondents should note that this Sources Sought Notice is not a formal solicitation announcement, no contract will be awarded from this announcement, and submission of capabilities statements does not restrict the Government's ultimate acquisition approach for the future formal solicitation.

Notice text

Sources Sought Notice

Sources Sought Notice

Page 3 of 3

Sources Sought Notice

*= Required Field

Sources Sought Notice

Page 1 of 3

This is a SOURCES SOUGHT NOTICE for market research purposes only to determine the availability of potential businesses with capabilities to provide the service described in the Statement of Work (SOW). Potential offerors are invited to provide information via e-mail to natalie.acevedo@va.gov. All responses will be used to determine the appropriate acquisition strategy for a potential future acquisition according to Performance Work Statement (PWS).

Potential contractors shall provide, at a minimum, the following information to natalie.acevedo@va.gov:

1) Name, address, point of contact name, phone number, and e-mail address.

2) Brief capability statement with enough information to determine if the company can meet the requirement. The Capabilities Statement for this sources sought is not expected to be a Request for Quote nor does it restrict the Government to an ultimate acquisition approach but rather provide a short statement regarding the company's ability to provide the services as detailed in the Statement of Work. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement.

3) Statement attesting, they are properly certified in accordance with the PWS.

The capabilities will be evaluated solely for the purpose of determining the appropriate acquisition strategy for this requirement. The Government must ensure there is an adequate competition among the potential pool of available contractors using SBA website.

This synopsis is for information and planning purposes only and is not to be construed as a commitment by the Government nor will the Government pay for information solicited. This synopsis is not a solicitation announcement for Request for Quote. No formal solicitation document exists at this time, and no contract will be awarded from this announcement. Respondents will not be notified of the results of the evaluation. Interested contractors should respond via email by 10:00 AM (EST) on December 10, 2025.

PERFORMANCE WORK STATEMENT SUMMARY:

The VANJ HealthCare System (VANJHCS) Lyons Campus requires an annual service contract to provide Licensed Operator in Charge Services to our Wastewater Treatment Plant. The Contractor will be responsible for overseeing and operation of the Wastewater Operations including the collection system and keeping the facility in compliance with all New Jersey Department of Environmental Protection rules and regulations. The physical plant is located at the VANJ Healthcare System 151 Knollcroft Road Bldg.141 Lyons, NJ 07939.

The facility at Lyons consists of an extended aeration, activated sludge wastewater treatment plant with a variable design capacity of 200,000 to 1,000,000 gallons per day (GPD), serving a medical center population of approximately 1,800 patient, staff and visitors. The present flow is approximately 50,000 - 80,000 (GPD). The plant process flows through and consists of two aeration tanks, two Clarifiers, two sand filters, a Copper removal system consisting of two filters and an outflow where final disinfection is done by ultraviolet lights (UV) before discharge to a receiving stream. In addition to the plant pumps and blower equipment, emergency power is supported by a 300kw emergency diesel generator set.

2. The WWTP has recently completed a modernization program and as a result has made many repairs and upgrades including the installation of a new UV System and a Copper Removal System. The plant requires a Full Time S3/C1 Licensed Operator in Charge (LOIC) in accordance with (IAW) New Jersey Department of Environmental Protection (NJDEP) Regulations N.J.A.C. 7:10A.

3. Final Surface Water Permit, NJPDES Permit No. NJ0021083

4. Residual General Permit Authorization, NJPDES Permit No. NJG0212164

DISCLAIMER

This sources sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

Files

File Type Posted
36C24226Q0186.docx DOCX document

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity