B407 Roof Inlet Pipe Lining Repair
Closed Pre-Solicitation Posted
- Solicitation number
- PANMCC26P0000045033
- Agency
-
MICC Fort Sam Houston
Mission and Installation Contracting Command, Department of Defense
- Responses due
- Set-aside
- 8(a) Sole Source
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- Fort Myer, Virginia, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Sam Houston intends to solicit an 8(a) sole-source construction and repair service agreement for roof inlet pipe lining repair at Joint Base Myer-Henderson Hall, Fort Myer, Virginia, with responses to the sources-sought notice due July 2, 2026.
The work addresses water infiltration and active water damage at Spates Hall (Building 407), a recently modernized Garrison Dining Facility. The scope comprises selective demolition of ceiling materials, installation of epoxy resin pipe lining in five existing 3- to 6-inch diameter cast or ductile-iron drain lines (15 to 20 feet of lining per location), and architectural finishes including gypsum board installation and paint restoration to close drain pipes with watertight assemblies. All work must comply with Unified Facilities Guide Specifications (UFGS) Division 09-Finishes, 22-Plumbing, and 33-Utilities (November 2025 or latest version) and Davis-Bacon Wage Act requirements.
Performance period does not exceed 45 calendar days, with regular working hours Monday through Friday, 0700 to 1530. All contractor and subcontractor personnel must pass background checks, E-Verify clearance, AT Level I awareness training, DOD IA awareness training, and obtain JBM-HH Installation Access Control Pass (Form 190-16x). Contractor shall submit a CPM/PERT or linked GANTT schedule, accident prevention plan, safety plan, pipe-lining material specifications with MSDS, and paint color specifications within 14 calendar days before mobilization. A 365-day (or 12-month, whichever is longer) warranty is required. Payment is made through Wide Area Work Flow (WAWF). The Contract Officer Representative is David S. Mayeda, P.E., 520-691-4600, david.s.mayeda.civ@army.mil.
NAICS 238220 applies (small business size standard $19.0 million); PSC Z2NE.
Notice text
The Government requires a construction and repair service agreement to address water infiltration from roof inlet pipes at Spates Hall (Building 407) on Joint Base Myer-Henderson Hall, Fort Myer, VA. The primary objective is to repair five 3-inch to 6-inch roof drain lines using an in-place epoxy resin pipe-lining system. This is an emergency requirement intended to stop active water damage and prevent the imminent risk of mold growth within the facility.
See attached Statement of Work(SOW)
Files
| File | Type | Posted |
|---|---|---|
| Sources-Sought-JBMHH B407 Roof Inlet Pipe Lining Repair.pdf | ||
| SOW-MY-B407-RoofInletPipeLiningRepair-2.0.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| JBMHH Stormwater Management Facility Maintenance and Repair Services | MICC Fort Sam Houston | No set-aside | |
| Z1ND--EL paso lift station piping repair | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| Z2NZ-- 658-23-108 Correct Stormwater Drainage | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Y1DZ--598-22-115 Site Utility Infrastructure-NLR | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Watervliet Arsenal (WVA) Replacement of the 300 Line Chrome Piping | ACC Warren | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity