B16 Generator PLC Upgrade
Closed Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- PANNGB-26-P-0000029437
- Agency
-
Army National Guard
Department of the Army, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- McConnell AFB, Kansas 67221, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Kansas Air National Guard at McConnell Air Force Base is seeking to procure inspection, troubleshooting, repair, and replacement services for a Building 16 Generator PLC (Programmable Logic Controller) upgrade project. The primary objective is to restore a Telmecanique/Advantys STBNMP2212 PLC Island controlling a Kohler 1.5 MW Diesel Generator set to its original installation parameters, with contractor responsibilities including verification of restored operations, communication functionality, and generator performance testing in both standalone and parallel modes. Key qualifications include demonstrated bonding capability and documented past performance in PLC repair and generator system operations. This is currently a sources sought announcement for market research purposes, with interested parties required to submit a completed sources sought response form by January 28, 2026, including company information, socio-economic status, bonding capability documentation, and capabilities statement to 184WG.MSG.CONTRACTING@us.af.mil with the subject line "Sources Sought B16 Generator PLC Upgrade." The procurement falls under NAICS code 238210 (Electrical Contractors and Other Wiring Installation Contractors) with PSC category J059 (Maintenance/Repair/Rebuild of Electrical and Electronic Equipment Components).
This opportunity is set aside exclusively for small businesses, with the applicable small business size standard of $19 million for the NAICS category. A critical contractual requirement mandates that the prime contractor must subcontract with 3E Company, the designated OEM regional representative for Kohler, to ensure proper coordination with the original equipment manufacturer. The project scope includes replacing seven PLCs total, with three specifically located in Building 16, along with five I/O modules, updating communications infrastructure from Modbus+ to Ethernet-based systems, and replacing power transducers. An optional scope element involves installing individual controllers for each generator to eliminate single points of failure. The specific contract value has not been disclosed in this pre-solicitation notice; however, the small business threshold of $19 million indicates the potential award magnitude. Contractors must comply with base access procedures, safety regulations, and hazardous materials management requirements at McConnell Air Force Base throughout project execution.
Notice text
This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond.
Kansas Air Nationl Guard, McConnel AFB, Kansas, will soon be soliciting for a project for Building 16 Generator PLC Upgrade. Work shall consist of but is not limited to the following: Inspect, troubleshoot, and repair or replace generator PLC controls. PLC is a Telmecanique/Advantys STBNMP2212 PLC Island and connected output modules controlling a Kohler 1.5 MW Diesel Generator set. Contractor is to troubleshoot and repair PLC to original installation parameters. Verify restored PLC/Generator set operations and communication. Ensure repairs with a function check of generator operations in standalone and parallel modes. There will be an option to install a Hot Switch Bypass. Refer to attached SOW.
For this requirement, the small business size standard is $19 million for NAICS 238210. In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted.
NOTE: Prime contractor is required to subcontract with 3E Company (electrical Engineering & Equipment Co.) since they are the designated OEM regional representatvie of Kohler.
Complete and return attached sources sought form to include bonding capability and advise on your capabilities and or past perfromance in terms of the projected requested. Include the following email subject line "Sources Sought B16 Generator PLC Upgrade" when emailing, to 184WG.MSG.CONTRACTING@us.af.mil. Use the same email address if you have additional questions.
Files
| File | Type | Posted |
|---|---|---|
| 20251006-B16-PRQE232380-SOW PLC Upgarde.docx | DOCX document | |
| A.02 (A-15) Sources Sought Response Form Workable.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| B16 Generator PLC Upgrade | Solicitation | |
| B16 Generator PLC Upgrade | Pre-Solicitation | |
| This notice | Pre-Solicitation |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity