About this opportunity
This solicitation from the Department of the Air Force Materiel Command Air Force Sustainment Center seeks to procure five sets of B-1B wing stand sets and installation services. The stands must support ten personnel each, measure roughly 55 feet long, and be constructed of carbon steel and aluminum. Installation must be completed within ten business days of delivery at Tinker Air Force Base in compliance with all environmental, safety and vehicle regulations. Proposals are due by April 24, 2020 and will be evaluated based on meeting the requirements outlined in the amended statement of work.
This is a total small business set-aside with a place of performance of Tinker Air Force Base in Oklahoma City, Oklahoma. Each wing stand set supports ten personnel and measures approximately 55 feet in length. Installation services must be completed within ten business days of delivery. The NAICS code is 238990 and PSC code is J063. The solicitation number is FA812520Q00680001 and has a response deadline of April 24, 2020.
Notice text
The Purpose of This Amendment Is: to post industry question and answers and update the Statement of
Work.
FIRST= The following questions are hereby answered as follows:
Question 1 - - Regarding the requirement for the plan view profile to taper from wing root to the wing tip, is it also the intent that the stand set be flat
with a uniform level and not slope downward from wing root to wing tip?
Answer 1 - - Correct. The requirement to slope the stand downward is no longer present. Maintain flatness level with the ground.
Question 2- - SOW section 2.1(k) specifies that that deck apertures be 1" in diameter. Is this correct?
Answer 2- - - SOW section 2.1(k) has been replaced with "slip-resistant decking with perforations large enough to prevent fluid build-up on surface."
SECOND= The statement of work is hereby updated and attached.
THIRD= All other terms and conditions remain unchanged and in full force and effect.
Attachments
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment FA812520Q00680001 SF 30 (1).pdf | ||
| A20-055E Wing Stand Set - SOW (04-08-2020).pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| B-1B Wing Stand Sets | Award Notice | |
| B-1B Wing Stand Sets | Solicitation | |
| B-1B Wing Stand Sets | Solicitation | |
| B-1B Wing Stand Sets | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity