Armaments airline and power outlet

Closed Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
FA480024MP0001
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Langley AFB, Virginia 23665, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This Solicitation Notice is for a contract with the Department of the Air Force Air Combat Command to provide new air line drops and power outlets to support a bead blaster and ultrasonic parts washer at Langley AFB, VA. The key requirements include installing copper air lines with ball valves, air regulators, and flex lines, as well as an electrical outlet, conduit, wire, and a 20-amp breaker. The contractor will need to shut off the air compressor, bleed air pressure, and verify proper operation after the installation is complete. The stated evaluation criteria are not provided, but the solicitation deadline is May 13, 2024.

The contract is set aside for small businesses. No incumbent contractors are named. The total value of the contract is not specified, but the scope includes installing two air drops and one electrical outlet. The place of performance is Langley AFB, VA 23665.

Notice text

Shut off air compressor and LOTO circuit

- Bleed all air pressure off piping

- Cut in a 2”x2”x3/4” copper press tee, install ball valve in the ceiling for the parts washers

- Cut in a 2”x2”x1” copper press tee, install ball valve in the ceiling for the sand blaster

- Take LOTO off the air compressor circuit, and turn air compressor back on

- Leak check the new fittings that where installed

- Fabricate support hangers in the ceiling for both air line runs

- Fabricate support hangers coming down the wall for both air line runs

- Run out ¾” copper pipe from new ball valve down to parts washer

- Install ball valve, air regulator, and a hose that will connect to the parts washer

- Drill hole through the block wall for the sand blaster air line

- Run out 1” copper pipe from new ball valve, through the block wall and down to sand blaster

- Install ball valve and tee fitting, run 2 hoses off the tee to each connection on the sand blaster

- Seal up hole around the 1” copper pipe where it goes through the block wall

- Drill an additional hole in the same wall for the electrical conduit

- Run out conduit from panel F751_N_1PPC out through the wall and down to sand blaster

- Install a 20amp receptacle for the sand blaster

- Seal up hole around the conduit where it goes through the block wall

- Open air valves to each machine and verify nothing is leaking

- Turn power on to the receptacle and check for proper voltage

Files

File Type Posted
Statement of Requirement.pdf PDF

Notice history

Notice Type Posted
Fire Truck Power Divider Latest solicitation Solicitation
This notice Original Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Langley AFB Washer/Dryer Lease and Maintenance Langley AFB, VA 23665, USA · NAICS 532210 Air Combat Command Total Small Business
Airfield Lighting Computer System Langley AFB, Virginia 23665, United States · NAICS 238210 Air Combat Command No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity