The U.S. Army Corps of Engineers is seeking proposals for the design-build construction of a two-story ARCENT Readiness Training Center (ARTC) Search House with a pre-engineered building, simulated tunnel system, and associated site work. The project scope includes site grading, drainage, survey, geotechnical investigation, concrete foundations, and power distribution. The exterior will feature pre-finished insulated metal wall panels on a structural steel frame, with a pre-finished insulated metal panel gable roof. No water, sewer, or utility connections are required. The solicitation has a due date of January 2, 2024.

This contract does not have any set-aside designation. The place of performance is Kuveyt. The estimated contract value is approximately $615,000. The project includes the construction of one Search House facility with a building footprint of 615 square meters, and an above-ground simulated tunnel system with 1.83-meter diameter reinforced concrete pipes and four concrete entryways.

Notice text

5 versions

Update #5 · Latest ·

The project consists of the design-build construction of a two-story ARCENT Readiness Training Center (ARTC) Search House with pre-engineered building (PEB), simulated tunnel system, and associated site work. The project consists of construction of one (1) Search House, site grading and drainage, survey, geotechnical investigation, concrete foundations, power distribution to the building and simulated tunnel system. The scope of the Search House construction will consist of living room, bedrooms, kitchen, bathrooms, laundry, AAR, utility, electric room, simulated basement etc.Building footprint is 615 square meters (37.5mX16.4m). The exterior of this building will be prefinished insulated metal wall panels on structural steel frame. The roof will be prefinished insulated metal panel in a gable configuration over steel structure. No water and sewer services will be needed for the building. No utility connection to appliances and plumbing is needed. An above-ground simulated tunnel system consisting of Reinforced Concrete Pipes and four (4) concrete entryways will be installed. The pipe size for tunnel is 1.83m in diameter and of RGRCP, ASTM C-76. **Amendment 0001 - Clause 52.236-27 has been updated to revise the site visit Information, and to attach the past performance assessment and questionnaire to the solicitation. **Amendment 0002 - provides clarification on page numbering and adds site visit information. **Amendment 0003 - Updates plans and specs and bonding information.

Update #4 ·

The project consists of the design-build construction of a two-story ARCENT Readiness Training Center (ARTC) Search House with pre-engineered building (PEB), simulated tunnel system, and associated site work. The project consists of construction of one (1) Search House, site grading and drainage, survey, geotechnical investigation, concrete foundations, power distribution to the building and simulated tunnel system. The scope of the Search House construction will consist of living room, bedrooms, kitchen, bathrooms, laundry, AAR, utility, electric room, simulated basement etc.Building footprint is 615 square meters (37.5mX16.4m). The exterior of this building will be prefinished insulated metal wall panels on structural steel frame. The roof will be prefinished insulated metal panel in a gable configuration over steel structure. No water and sewer services will be needed for the building. No utility connection to appliances and plumbing is needed. An above-ground simulated tunnel system consisting of Reinforced Concrete Pipes and four (4) concrete entryways will be installed. The pipe size for tunnel is 1.83m in diameter and of RGRCP, ASTM C-76. **Amendment 0001 - Clause 52.236-27 has been updated to revise the site visit Information, and to attach the past performance assessment and questionnaire to the solicitation. **Amendment 0002 - provides clarification on page numbering and adds site visit information.

Update #3 ·

 Amendment 0001 - Clause 52.236-27 has been updated to revise the site visit Information, and to attach the past performance assessment and questionnaire to the solicitation.

Electronic Proposal Submission is required through the Army’s Electronic File Sharing Service, Procurements
Integrated Enterprise Environment (PIEE) (https://piee.eb.mil/).

Update #2 ·

The project consists of the design-build construction of a two-story ARCENT Readiness Training Center (ARTC) Search House with pre-engineered building (PEB), simulated tunnel system, and associated site work. 

In accordance with FAR 9.502(c), "An organizational conflict of interest (OCI) may result when factors create an actual or potential conflict of interest on an instant contract..."  In this case, FAR 9.505(b)(2) applies as this requirement has been solicited previously and those contractors who received the solicitation may have a potential OCI and shall be prohibited from receiving the contract award.  If an offeror requests an exception to the prohibition of an OCI, then the offeror shall submit an Organizational Conflict of Interest Mitigation Plan with its offer for evaluation.  If the apparently successful offeror submits an acceptable Organizational Conflict of Interest Mitigation Plan, and the plan is approved, then the Contracting Officer will incorporate the Organizational Conflict of Interest Mitigation Plan into the resulting contract.  Organizational Conflict of Interest Mitigation Plans are discussed in DFARS Subpart 209.571-4 Mitigation.”

Electronic Proposal Submission is required through the Army’s Electronic File Sharing Service, Procurements Integrated Enterprise Environment (PIEE) (https://piee.eb.mil/).

Update #1 ·

The project consists of the design-build construction of a two-story ARCENT Readiness Training Center (ARTC) Search House with pre-engineered building (PEB), simulated tunnel system, and associated site work. The project consists of construction of one (1) Search House, site grading and drainage, survey, geotechnical investigation, concrete foundations, power distribution to the building and simulated tunnel system. The scope of the Search House construction will consist of living room, bedrooms, kitchen, bathrooms, laundry, AAR, utility, electric room, simulated basement etc.Building footprint is 615 square meters (37.5mX16.4m). The exterior of this building will be prefinished insulated metal wall panels on structural steel frame. The roof will be prefinished insulated metal panel in a gable configuration over steel structure. No water and sewer services will be needed for the building. No utility connection to appliances and plumbing is needed. An above-ground simulated tunnel system consisting of Reinforced Concrete Pipes and four (4) concrete entryways will be installed. The pipe size for tunnel is 1.83m in diameter and of RGRCP, ASTM C-76.

Files

Notice history

Notice Type Posted
ARCENT Readiness Training Center (ARTC) Search House Award Award Notice
This notice Latest solicitation Solicitation
Camp Buehring ARCENT Readiness Training Center Search House Original Pre-Solicitation

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors