9999--A&E Arc Flash Hazard Short Circuit Coordination Study (VA-23-00053052)
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C24623R0081
- Agency
-
Veterans Integrated Service Network 6
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 541330 Engineering Services
- PSC
- 9999 Miscellaneous Items
- Place of performance
- 508 Fulton Street Durham NC 27705
Notice details come from SAM.gov. Updated .
About this opportunity
This sources sought notice is for an arc flash hazard analysis and short circuit coordination study at the Durham, North Carolina VA Medical Center. The Department of Veterans Affairs seeks engineering services to perform a power system report containing short circuit, protective device coordination, voltage drop, arc flash, and incident energy analyses on the electrical distribution system from utility lines to branch circuits across multiple buildings. Interested parties are to respond by July 10, 2023 with capabilities statements and intent to compete for solicitation number 36C24623R0081. The statement of work further describes requirements for site analysis, time-current coordination curves, calculations, labeling, training, and draft and final report deliverables.
This opportunity is set aside for service-disabled veteran-owned small businesses. The NAICS code is 541330 for engineering services up to $25.5 million in annual revenue. The PSC code listed is 9999. The statement of work and sources sought notice provide details on analyses of electrical systems across approximately 30 buildings to be completed over a 150-day performance period following notice to proceed in compliance with applicable industry standards and VA directives.
Notice text
Sources Sought Notice
Sources Sought Notice
Page 3 of 3
Sources Sought Notice
*= Required Field
Sources Sought Notice
Page 1 of 3
Arc Flash Hazard Analysis/Short Circuit Coordination Study, Durham, NC VAMC
Provide a power system report containing the results of a Short Circuit and Device Evaluation, Protective Device Coordination, Voltage Drop Analysis, Arc-Flash Analysis, and Incident Energy Analysis performed on the electrical distribution system.
RFP - 36C24623R0081
This Sources Sought is for Market Research purposes only and does not constitute a request for proposal.
RESPONSE DATA:
Responses to be sent to mark.hinton@va.gov and are to include a capabilities statement and an affirmative intent to compete.
NAICS CODE: 541330 - "Engineering Services"
Size Standard: 25.5 million
PSC: 9999 Miscellaneous Items
Due Date for Responses: 10 July 2023, by 10:00 AM EST
Files
| File | Type | Posted |
|---|---|---|
| 36C24623R0081.docx | DOCX document | |
| SOW for Arc Flash Hazard Analysis 2023.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| C213--Arc Flash Hazard Coordination Study | Award Notice | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| C211--589A6-24-410, Replace MDP Panel Bld 89| EKH | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| 657A5-26-111, Triennial Electrical Testing | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business Sole Source | |
| 6150--Correct Electrical Deficiencies | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--Project No. 583-22-106- Replace Electrical Panels & Expand Distribution. | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity