6840--PhenoMaster Control System (VA-26-00008877) - (Grant Funded)

Closed Pre-Solicitation Posted

Not the latest version. See the latest special notice from .

Solicitation number
36C25225Q0713
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Jesse Brown VA Medical Center Department of Veterans Affairs Chicago, Illinois 60612, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Integrated Service Network 12 is conducting market research through a Sources Sought Notice to identify qualified vendors capable of providing the TSE Systems IntelliCage-PhenoMaster System or an equivalent product. This specialized behavioral and metabolic phenotyping platform is designed for preclinical research to conduct comprehensive neuro-metabolic toxicological phenotyping in mice, specifically to assess the impact of military-associated toxicant exposures on neurocognitive, neuropsychiatric, and metabolic disease risks. The procuring activity seeks vendors that can meet minimum technical specifications while demonstrating relevant past performance capabilities and appropriate business certifications. Qualified respondents must submit company information, business size and socio-economic status documentation, product technical documentation, and past performance data by October 31, 2025, at 5:00 PM EST. It is important to note that this Sources Sought Notice is issued for market research and planning purposes only and does not constitute a formal solicitation or guarantee of future contract award.

This procurement opportunity is designated as a Total Small Business set-aside. The system specifications include simultaneous testing capability for 16 single-housed mice across 16 PhenoMaster Cages, 4 IntelliCages for behavioral testing of up to 16 mice each in four separate groups, and 3 medium Climate Control Chambers with programmable temperature controls. The system must incorporate advanced monitoring capabilities including oxygen and carbon dioxide sensors for energy expenditure and respiratory exchange ratio measurements, hydrogen and methane sensors for microbiome activity assessment, and programmable food and water intake controls with three-dimensional activity tracking. The funding for this purchase has been grant-funded to support the Department of Veterans Affairs' research mission. The applicable NAICS code is 334516 (Analytical Laboratory Instrument Manufacturing) and the PSC code is 6840 (Laboratory Equipment and Supplies).

Notice text

Sources Sought Notice

Brand Name or Equal TSE Systems IntelliCage-PhenoMaster System

Notice Type:Â Sources Sought

NAICS Code:Â 334516 Analytical Laboratory Instrument Manufacturing

PSC Code:Â 6640 Laboratory Equipment and Supplies

Introduction:

This is a Sources Sought Notice issued solely for market research and planning purposes. It does not constitute a Request for Quote (RFQ), Invitation for Bid (IFB), or Request for Proposal (RFP), nor does it guarantee a future solicitation or contract award.

The Department of Veterans Affairs (VA) is seeking qualified sources that can provide the TSE Systems IntelliCage-PhenoMaster System or an equal product that meets the Government s minimum technical requirements.

Background:

The IntelliCage-PhenoMaster System is a specialized, integrated behavioral and metabolic phenotyping platform used in preclinical research. It allows for automated, high-throughput monitoring of group-housed rodents in a home-cage environment, minimizing stress and improving data quality.

Funds were provided to purchase a TSE Systems IntelliCage-PhenoMaster System that has been customized to provide the necessary components for conducting comprehensive neuro-metabolic toxicological phenotyping in mice to determine the impact of military-associated toxicant exposures on neurocognitive/neuropsychiatric and metabolic disease risk while accelerating testing of interventions to mitigate these risks.

Salient Characteristics:

1) Simultaneous testing of behavior in 4 groups of up to 16 mice each (4 IntelliCages), with two acclimation cages (for housing prior to testing).

2) Simultaneous testing of 16 single-housed mice (16 PhenoMaster Cages) for:

Energy expenditure (EE) and respiratory exchange ratio (RER) (O2 and CO2 sensors)

Microbiome activity (H2 and CH4 sensors

Food and water intake (with programmable access control)

Body weight changes

Three-dimensional activity

3) 3 medium Climate Control Chambers (programmable to dynamically control temperature, light, and humidity), one will house 4 IntelliCages, and two will house the PhenoMaster cages (8 each).

The number of cages requested allows simultaneous assessments of 4 groups in a 2 x 2 matrix: control vs. toxicant-exposed and placebo vs. intervention. Thus, we will be able to run treatments and controls concurrently, which will facilitate statistical analyses should batch effects emerge. The climate control chambers will allow us to simulate extreme environmental conditions during service-related toxin exposure, that includes high and low temperatures and high and low humidity.

The necessary components (model numbers, shown in quote) to allow for detailed NeuroMetabolic Toxicology Studies are grouped below by purpose. Numbers shown in ( ) the quantities of each component required.

1. The main PhenoMaster Cages and Controls:

258000-PM-016-PhenoMaster Control (1)

994620-CSP-WS-16 CaloSys (1)

994620-CSP-SFPC-CaloSys SureFlow (1)

258001-PM-CC-001-PhenoMaster Universal Cage Control(16)

994621-CSM-01-PhenoMaster Climate Sensor (16)

994621-PM-HC-M-TP-PhenoMaster CaloCage Mouse TP Cage(16)

995101-CC-M-AC-NB-115V Climatic Chamber, 8 cages per unit (2)

999901-12-09-Installation / Instruction /initial Training on-site

700600-FI-DISK-01-Filter Disk (5)

700600-FI-SCH-05-Filter Unit 5" (5)

These components are the base elements and controlling system of the PhenoMaster cages that allow for the analyses capable with the additional equipment below. These items are required for all PhenoMaster studies.

2. Gas measuring components for RER/EE, 13/12C isotope, and Microbiome:

994620-CS-HSP-03-CaloSys (2)

994620-CS-12/13C-CO2-Gas Sensor (2)

994620-CS-H2-Gas Sensor (2)

994620-CS-CH4AB-Gas Sensor (2)

Each sensor listed above can monitor 8 PhenoMaster cages. These components of the PhenoMaster allow for in-depth measurements of metabolism using gas and isotope sensors. This includes: 1) measurements of energy expenditure (EE) to understand whether toxicants increase obesity, fatty liver, and diabetes risk by reducing the burning of calories; 2) measurements of the respiratory exchange ratio (RER) to understand whether toxicants specifically impair the ability to utilize specific macronutrients (carbohydrates or fat); 3) measurements of gases produced by the gut microbiome [hydrogen gas (H2) and methane (CH3)] to provide a functional assessment of the impact of toxicants on the gut microbiome that may also serve as a marker of intervention-mediated improvements in microbiome function; and 4) measurements of stable isotope-labeled substrates that will allow the research team to specifically interrogate whether toxicants induce deleterious changes in metabolic flux that are a marker of diabetes and fatty liver risk as well as potential measures for assessing the utility of targeted interventions.

3. Food/drink body weight and access control:

259999-SEN-DFBW-01-PhenoMaster, for measurement of 3 endpoints per cage: intake of liquid or food or body weight (48)

259999-DRI-BOT-M-PV allowing for two different liquid choices (bottles) per cage 32

259999-FEED-BAS-SP-M-PhenoMaster (16)

259999-FEED-BAS-PP-M-PhenoMaster (16)

259999-AC-M-PhenoMaster Access allowing two different food choices per cage 32

259999-BW-HOUS-M-PhenoMaster (16)

These components of the PhenoMaster system will allow us to determine whether toxicants increase or decrease food and/or water intake while also allowing us to quantify how toxicant exposures affect body weight and obesity risk. Furthermore, the controllers included here will allow us to conduct sophisticated studies in which we can control food access, a feature critical in metabolic disease risk for distinguishing between metabolic changes induced by increased food intake versus changes mediated by altered metabolism of food.

4. Three-dimensional activity:

302022-XY-M-PhenoMaster ActiMot3 XY-Frame (16)

302022-Z-M-PhenoMaster ActiMot3 Z-Frame (16)

302022-XYZ-M-TP-PhenoMaster Homecage Template (16)

These components will allow us to assess three-dimensional activity, which is important for several reasons: 1) activity burns energy, and these assessments will allow us to ascertain whether toxicants disrupt metabolism by altering energy utilization; 2) activity can be a sign of toxicity; and 3) changes in activity patterns over a 24-hour day (circadian rhythms) can indicate specific pathways of toxicity.

5. IntelliCage System:

290000-SB-2IC-00003-IntelliCage® by NewBehavior Bundle for 2 Intellicage cage setup (includes computer)

290000-EB-2IC-00004-IntelliCage® by NewBehavior Bundle for 2 Intellicage cage extension (2 extension cages to be connected to item 24.

acclimation cages

90000-IC-50100-IntelliCage cage body (2)

po 290000-IC-HC-2000-IntelliCage® by NewBehavior IntelliCage home-cage set (2)

Stand-alone climate chamber for IntelliCages

995101-CC-M-AC-WB-115V Climatic Chamber (1)

258001-PM-SW-EC-PhenoMaster Software License for 1 Environmental Chamber (required for stand-alone chamber system (i.e. not used with PhenoMaster) (1)

RS485 Cable (to connect the chamber to the computer) (1)

IntelliCage training and installation

999901-12-25-Application Training/remote

999901-12-05-Installation / Instruction/on-site

The IntelliCages are a critical component of this system because they will allow us to link neurocognitive function with metabolism, two domains of health increasingly linked to toxicant exposures and each other. The IntelliCages have many marked advantages over our traditional neurocognitive/neuropsychiatric behavioral testing approaches. These include: 1) automated, high-throughput screening protocols that allow for testing of up to 16 mice at the same time; 2) high standardization and reproducibility; 3) reduced operator-dependence, which reducing variability and workload; 4) improved validity due to minimal human interference; 5) programmed, validated behavioral testing paradigms; 6) flexibility to design additional testing schema; 7) testing under group-housed conditions, which reduces testing-induced artifacts from stress; and 8) assessments across the 24-hour day to identify alterations in circadian rhythms of behavior. These advantages result in better data faster, allowing for more toxicants and their interventions to be tested.

Submission Instructions:

Interested vendors must submit the following information via email to Erica Grimslid at Erica.Grimslid@va.gov no later than October 31, 2025, at 5:00 PM EST:

Company name, address, and DUNS/UEI number

Business size and socio-economic status (e.g., SDVOSB, VOSB, WOSB, etc.)

Product brochure or technical documentation showing how the proposed item meets or exceeds the salient characteristics

Past performance or experience providing similar systems

GSA/FSS contract number (if applicable)

Disclaimer:

This notice is for informational purposes only and does not obligate the Government to issue a solicitation or award a contract. The Government will not reimburse any costs associated with responding to this notice. Responses will be used solely to determine the availability of qualified sources.

Files

File Type Posted
36C25225Q0713.docx DOCX document

Notice history

Notice Type Posted
6840--PhenoMaster Control System (VA-26-00008877) - (Grant Funded) Latest special notice Special Notice
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
6640--Sole Source Post-Award Notice Individually Ventilated Cage Systems NAICS 332999 Veterans Integrated Service Network 4 No set-aside
6515--Inventory Management System Department of Veterans Affairs VA Phoenix Healthcare System Phoenix AZ 85012 · NAICS 334519 Veterans Integrated Service Network 22 No set-aside
6530--NX EQ Environmental Disinfection Systems Pulsed Xenon UV Light (VA-27-00012571) Nationwide · NAICS 334510 VA Strategic Acquisition Center Frederick No set-aside
6670--Gravimetric Scales VA Loma Linda Healthcare System Loma Linda CA 92357, United States · NAICS 334519 Veterans Integrated Service Network 22 No set-aside
Research Equip (LAMb) - Independent Ventilated Cage Systems - COLUMBIA | EDA: 9/25/26 Veterans Integrated Service Network 4 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity