667-17-2-132-0223- LINAC QA 3D Scanning Tank

Award Notice Posted

Solicitation number
VA25617Q0421
Agency
Awarded
to Sun Nuclear Corp.
Set-aside
Veteran-Owned Small Business

Opportunity facts

Contract number
VA25617P0795 Federal contract award
PSC
Not on record
Place of performance
Department Of Veterans Affairs Overton Brooks VA Medical Center 501 E. Stoner Ave Shreveport, LA 71101 71101 USA

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

Sources Sought Market Research to determine extent of Veteran Owned Small Business (VOSB) Capability for QA Scanning Tank for Linear Accelerator

DISCLAIMER

This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

This is a Request for Information. Accordingly the Governments intent is to conduct market research and provide notice to industry of its intent to solicit for certain services. Any information submitted by and obtained from industry as a result of this notice may be used in the development of the final acquisition strategy (e.g., set-aside, sole source, full and open competition, etc.) and may affect:

Feasibility of the requirement

Appropriateness of the NAICS Code

Approach to Implementation

Performance Work Statements or specifications

Any other industry concerns or questions



The Department of Veterans Affairs, Overton Brooks VA Medical Center, Shreveport, LA 71101 has a requirement for a Linear Accelerator QA Scan Tank. The Specifications are below.

Vendors who are capable of fulfilling this requirement and certified as SDVOSB or VOSB in the Vendor Information Pages at https://www.vip.vetbiz.gov/ are requested to submit a capability statement. Include firm s name (including any dba designation), DUNS, and FSS Contract Number; as well as a personal contact name, phone number, email address.

Set-Asides At this time the government is requesting information in order to provide a final determination related to set aside. Upon review of the market research and coordination of appropriate parties a determination will be made.

Questions: All questions and comments should be submitted to Paul Filhiol via email at paul.filhiol@va.gov by noon (CST) on 23 March 2017.



SPECIFICATIONS FOR SCANNING TANK

Radiation Oncology Department is looking to replace an obsolete 3D scanning tank used for

Linear Accelerator (LINAC) Annual QA, commissioning and QA after major repairs.



Salient Characteristics

(1) 3D tank used for LINAC beam scanning for commissioning and Annual QAs.



(2) Requirements

1. Cylindrical tank design

2. 65cm or grader scanning range

3. Preset scanning queues

4. Scan speeds up to 16mm/second

5. Eliminates set up subjectivity which affects data quality

6. Detector maintains consistent orientation for inplane, crossplane, and diagonal scans

7. Narrow side of scanning detector remains parallel to beam edge

8. Automated tank leveling, water surface, beam center detection.

9. Fast setup time

10. Large set of analytical tools for data analysis

11. Ability to store iterative data sets

Update #1 ·

Sources Sought Market Research to determine extent of Veteran Owned Small Business (VOSB) Capability for QA Scanning Tank for Linear Accelerator

DISCLAIMER

This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

This is a Request for Information. Accordingly the Governments intent is to conduct market research and provide notice to industry of its intent to solicit for certain services. Any information submitted by and obtained from industry as a result of this notice may be used in the development of the final acquisition strategy (e.g., set-aside, sole source, full and open competition, etc.) and may affect:

Feasibility of the requirement

Appropriateness of the NAICS Code

Approach to Implementation

Performance Work Statements or specifications

Any other industry concerns or questions



The Department of Veterans Affairs, Gulf Coast VA HealthCare System, Biloxi VAMC, Biloxi, MS has a requirement for Vital Sign Monitors. The Specifications are below.

Vendors who are capable of fulfilling this requirement and certified as SDVOSB or VOSB in the Vendor Information Pages at https://www.vip.vetbiz.gov/ are requested to submit a capability statement. Include firm s name (including any dba designation), DUNS, and FSS Contract Number; as well as a personal contact name, phone number, email address.

Set-Asides At this time the government is requesting information in order to provide a final determination related to set aside. Upon review of the market research and coordination of appropriate parties a determination will be made.

Questions: All questions and comments should be submitted to Paul Filhiol via email at paul.filhiol@va.gov by noon (CST) on 23 March 2017.



SPECIFICATIONS FOR SCANNING TANK

Radiation Oncology Department is looking to replace an obsolete 3D scanning tank used for

Linear Accelerator (LINAC) Annual QA, commissioning and QA after major repairs.



Salient Characteristics

(1) 3D tank used for LINAC beam scanning for commissioning and Annual QAs.



(2) Requirements

1. Cylindrical tank design

2. 65cm or grader scanning range

3. Preset scanning queues

4. Scan speeds up to 16mm/second

5. Eliminates set up subjectivity which affects data quality

6. Detector maintains consistent orientation for inplane, crossplane, and diagonal scans

7. Narrow side of scanning detector remains parallel to beam edge

8. Automated tank leveling, water surface, beam center detection.

9. Fast setup time

10. Large set of analytical tools for data analysis

11. Ability to store iterative data sets

Files

File Type Posted
VA256-17-Q-0421-001.docx DOCX document
VA256-17-Q-0421-000.docx DOCX document

Notice history

Notice Type Posted
667-17-2-132-0223- LINAC QA 3D Scanning Tank Latest Award Notice
This notice Original Award Notice

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors