6640--Porta Count Model 8408-T Respirator Fit Testing Equipment
Closed Pre-Solicitation Posted
- Solicitation number
- 36C24826Q0403
- Agency
-
Veterans Integrated Service Network 8
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- PSC
- 6640 Laboratory Equipment And Supplies
- Place of performance
- Bay Pines, Florida 33744, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs, Veterans Integrated Service Network 8 (VISN 8), through Network Contracting Office 8 (NCO 8), is procuring a PortaCount Respirator Fit Tester Model 8048 with associated accessories, software, and equipment to support respiratory protection fit testing operations. The VA intends to award this as a sole source, firm-fixed price contract to TSI Inc., the identified sole source provider of this specialized fit test system. Key requirements include compatibility with existing VISN 8 facility laboratory systems, reliability, and streamlined workflow capabilities, as well as compliance with the Bay Pines VA Healthcare System's Respiratory Protection Program SOP 516-138-028 and OSHA 1910 requirements. Responsible sources opposing the sole source determination may submit capability information and/or OEM Authorization Letters to demonstrate their ability to meet the requirement by the deadline of 1:00 PM EST on Wednesday, March 25, 2026. Submissions should be directed to Timothy Felix, Contract Specialist, at timothy.felix@va.gov and must include company information, points of contact, relevant experience, socioeconomic categories, and Federal Supply Schedule status if available.
This procurement carries no set-aside designations and currently identifies TSI Inc. as the incumbent/proposed contractor for the specialized equipment. The contract is intended to serve approximately 1,372 employees at Bay Pines VA Healthcare System and will replace aging equipment nearing end-of-service life. The contract period of performance runs from April 15, 2026 through June 30, 2026, with place of performance at Bay Pines VAMC, Building 24, Room 219, Bay Pines, Florida. The specific equipment package includes the PortaCount Model 8048 Respirator Fit Tester, FitPro Ultra Fit Test Software, Microsoft Surface Go Tablets (4 GB WiFi), N95-Companion technology, particle generator, alcohol supply, carrying cases, AC adapters, and standard accessory kits. The applicable NAICS code is 334516 (Analytical Laboratory Instrument Manufacturing) and the Product Service Code is 6640 (Laboratory Equipment and Supplies), with solicitation number 36C24826Q0403.
Notice text
Sources Sought Notice
Sources Sought Notice
Page 7 of 7
Sources Sought Notice
*= Required Field
Sources Sought Notice
Page 1 of 7
DESCRIPTION
Notice of Intent to Award as Sole Source: The Department of Veterans Affairs, Network Contracting Office 8 (NCO 8) intends to award a Sole Source, Firm-Fixed Price contract to TSI Inc., for the procurement of PortaCount Respirator Fit Tester - Model 8048.
It is the Government s belief that the proposed candidate is the sole source provider of a specialized fit test system with accessories, FitPro Ultra Fit Test Software, and the Microsoft Surface Go Tablets. PortaCount Respirator Fit Tester - Model 8048.
Currently, VISN 8 facility laboratories use the PortaCount Respirator Fit Tester - Model 8048, which ensures compatibility, reliability, and streamlined workflows.
This announcement is being issued for information purposes only and does not constitute a solicitation or request for competitive proposals. Responsible sources that oppose this decision may identify their interest by submitting their capability information and/or an OEM Authorization Letter by 1:00PM EST, on Wednesday March 25, 2026.
Interested firms must indicate the following:
1. Name and address of company
2. Primary point of contact, including phone number and e-mail address
3. Federal Supply Schedule (FSS), if available
4. Applicable socioeconomic categories and any pertinent information, which demonstrates firm s ability to meet the requirement.
5. Experience. Brief descriptions of recent and relevant projects for tasks similar to those identified in paragraph one of this document. (1 page maximum)
6. Business size (the applicable NAICS code for this requirement is 334516
7. Product and Service Code: 6640
A decision by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification. All inquiries and submittals must be sent via email to Timothy Felix, Contracting Specialist, at timothy.felix@va.gov. Telephone inquiries will not be accepted.
This notice is NOT a formal request for quote or proposals. No formal solicitation document exists at this time. The information in this notice is for information and planning purposes only and is not to be construed as a commitment by the government.
See attached document: SON
Statement of Need
PURPOSE:
The following purchase of needed equipment is to be able to complete proper respiratory protection fit testing for 1372 employees within the Bay Pines V.A. Healthcare System (BPVAHCS). The Employees that are included in the Respiratory Protection Program include Healthcare Professionals, Facility Management Services (F.M.S.) Employees, and Environmental Management Services (E.M.S.) Employees. Respiratory protection fit testing is required per Respiratory Protection Program SOP 516-138-028 of the BPVAHCS and is an OSHA 1910 requirement. The purchase of this equipment will ensure that BPVAHCS is in compliance with SOP 516-138-028. Also, this new equipment will be replacing old equipment that is due to expire on its service life. The old equipment will no longer be able to be used due to its software expiration and will not be compatible with the new equipment being purchased. New software for the new equipment is already available and complies with the Office of Information and Technology (OI&T) requirements and has already been uploaded to available computers that are used for respiratory protection fit testing. Base Only, Supplies, Firm Fixed Price contract.
Period of Performance:
4-15-2026 to 6-30-2026
Place of Performance:
Bay Pines VAMC
10000 Bay Pines Blvd. Building 24, Room 219
Bay Pines, FL., 33744
DESCRIPTION OF EQUIPMENT:
Product Details
The PortaCount Respirator Fit Tester is a quantitative respirator fit tester. It features intelligent touchscreen solutions that support respiratory protection programs from training through compliance. The 8048-T Kit lets you begin testing immediately, with everything you need for accurate, easy, fast, and flexible respirator fit testing sessions.
Software & Application Details
TSI has redesigned every aspect of the PortaCount Fit Tester's FitPro Ultra software. An all-new user interface and industry-first features combine to create the most powerful fit test instrument available. From touchscreen tablets to PC laptops, the software is easy to use and similar to applications on your own personal devices.
Items included in the 8048-T PortaCount Respirator Fit Tester Kit
PortaCount Respirator Fit Tester Model 8048 Microsoft Surface Go® Tablet (4 GB)
WiFi USB Adapter USB Cable
N95-Companion technology Carrying case
AC adapter
AC power supply with global plug adapters
Alcohol supply (sixteen 30 ml bottles of 99.5% reagent grade isopropanol enough for
~240 hours of operation)
FitPro Ultra Software Particle generator
Standard accessory kit (twin tubing, zero filters, spare wicks, alcohol fill capsule and cartridge)
Filtering Facepiece fit testing kit (probe insertion tool, probes, lock nuts, lanyard)
ASSIGNMENT OF RESPONSIBILITIES:
Per Respiratory Protection Program-SOP 516-138-028
a. Safety Section of Facilities Management Service (FMS). The Safety Section of FMS is responsible for:
Overseeing the implementation of the program and ensuring compliance with all regulatory requirements.
Assessing the need for Respiratory Protection and for determining the type and level of Respiratory Protection required.
Ensuring Occupational Health is notified of job functions requiring Medical Surveillance due to use of respirators.
Ensuring Respiratory Protection training is available for affected employees.
Performing periodic evaluations of the effectiveness of the Respiratory Protection Program.
Conducting OSHA-accepted Quantitative Fit Test (QWFT) Protocol using TSI Porta-Count fit test machines. In the event of a power outage, extreme virality mandating open-air fit testing, extreme supply shortage of disposable respirators or fit testing supplies, and/or loss of appropriate fit testing location wherein a QWFT Protocol is no longer feasible, an OSHA-accepted Qualitative Fit Test (QLFT) Protocol will be used.
Files
| File | Type | Posted |
|---|---|---|
| 36C24826Q0403.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Respirator Fit Testing | Veterans Integrated Service Network 5 | No set-aside | |
| Respirator Test Fit Preventative Maintenance and Calibration | Naval Sea Systems Command | No set-aside | |
| 6550--Sources Sought: Tuberculosis Testing Reagents and Consumables for the Buffalo VA Medical Center. In support of the Tuberculosis (TB) Testing Program | Veterans Integrated Service Network 2 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities