The Department of Veterans Affairs, Veterans Integrated Service Network 22, is issuing a sources sought notice and request for information to identify qualified vendors for a Formalin Laboratory Recycler for the VA New Mexico (Albuquerque) Healthcare System, with responses due July 10, 2026. This is market research only and does not constitute a solicitation; responses cannot form binding contracts and responders bear all associated costs. No set-aside is anticipated.

The VA seeks a brand-name or equivalent unit meeting minimum specifications: 10-gallon boiler and receiver capacity with internal shelving, single standard electrical outlet requirement, mobile and accessible boiler, air-cooled condenser without glass parts, user touch-screen controls, built-in post filter, vapor sensor with automatic shutdown, overtemperature shutdown device, and capability to recycle formalin consistently back to 10–12% purity for indefinite reuse. The reference product is a B/R Instrument Corporation Pureform Formalin Recycler Model 2100 or equal.

Vendor responses should include company information, business size status and certifications, manufacturer or distributor details, existing FSS or federal contract holdings, pricing for market research purposes, DUNS number, and detailed capability statements demonstrating product conformance to all salient characteristics. Responses must be submitted via email to Contract Specialist Kahlfanie Carabon at kahlfanie.carabon@va.gov. The VA will use submitted information to assess qualified sources under NAICS 334516 (size standard 1,200 employees) and may publish a formal solicitation following review.

Notice text

THIS REQUEST FOR INFORMATION (RFI) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.

THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).

DISCLAIMER

This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

SOURCES SOUGHT DESCRIPTION

This is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334516 (size standard of 1200 Employees). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement.

The Department of Veterans Affairs (VA), VISN 22 Network Contracting Office, is seeking sources that can provide a Formalin Laboratory Recycler that at a minimum meets the following salient characteristics with a brand name or equal product for the New Mexico (Albuquerque) VA Healthcare System:

The boiler and receiver size must hold a minimum of 10 gallons.

The unit must have internal shelving for the receiver.

The unit must require only one standard electrical power outlet.

The unit must include a mobile and accessible boiler.

The unit must use an air cooled condenser without glass parts.

The unit must be fully accessible for on-site service.

The unit must be enclosed in a cabinet

The unit must be capable of taking power from standard electrical outlets.

The unit must have user touch screen control for operation.

The unit must have a built-in post filter.

The unit must include vapor sensor to monitor air and alarm with automatic shutdown in case of excess vapor detection.

The unit must have an overtemperature shutdown device.

The unit must consistently recycle back to 10-12% purity.

The unit must be room temperature and ready to re-buffer for use.

The unit must recycle indefinitely without degradation of the formalin overtime.

Brand name Info:

BRAND

PRODUCT DESCRIPTION

PRODUCT #

QTY

B/R Instrument Corporation

Pureform Formalin Recycler

2100

1

N/A

Installation

N/A

N/A

N/A

On-site training

N/A

N/A

The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications.

If you are interested, and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:

(1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)

(2) Is your company considered small under the NAICS code identified under this RFI?

(3) Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?

(4) If you re a small business and you are an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?

(5) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.

(6) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract?

(7) Please provide general pricing for your products/solutions for market research purposes.

(8) Please state your company s DUNS number.

(9) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes?

*** Submissions addressing Section (9) should show clear, compelling and convincing*** evidence that all equal to items" meet all required salient characteristics.

Responses to this notice shall be submitted via email to Kahlfanie.Carabon@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Friday, July 10th, 2026, at 3:00 P.M. Pacific Time. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.

Files

File Type Posted
36C26226Q1056.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
6550--Abbott Architect i1000 Reagents Department of Veterans Affairs Southern Arizona VA Healthcare System (VA Tucson) Tucson, Arizona 85723, United States · NAICS 325413 Veterans Integrated Service Network 22 No set-aside
6515--Sterilizer Valley Coastal Bend South Texas Veterans Affairs VA Harlingen Healthcare Center Harlingen TX 78550 · NAICS 339112 Veterans Integrated Service Network 17 No set-aside
Osmometer Equipment Replacement (OsmoPro Max) Biloxi, Mississippi 39531, United States · NAICS 423450 Veterans Integrated Service Network 16 No set-aside
RFP-797-FSS-03-0001-R1: 66III Cost-Per-Test, Clinical Laboratory Analyzer United States · NAICS 334516 Veterans Integrated Service Network 12 No set-aside
S205--Media and Scrap Metal Recycling - Hudson Valley VAMC NAICS 562920 Veterans Integrated Service Network 2 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity