6515--robot arm purchase

Closed Pre-Solicitation Posted

Solicitation number
36C24626Q0729
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Richmond Veterans Affairs Medical Center Richmond, Virginia 23249, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs, Network Contracting Office 6, on behalf of Richmond VAMC for the Fredericksburg Health Care Center, is conducting market research through a Sources Sought notice to identify qualified vendors capable of supplying an industrial collaborative robot arm by July 6, 2026, at 4:00 PM Eastern Time.

Place of performance is the Fredericksburg Health Care Center. The robot arm must meet detailed technical specifications including a minimum 25-kilogram payload, 1750-millimeter reach, minimum 6 degrees of freedom, and 245-millimeter diameter base footprint. Electrical requirements are 110–120V 60Hz VAC with maximum 750-watt consumption. The system must incorporate force sensing (X-Y-Z) with 200.0-newton minimum range and 5.5-newton precision; torque sensing with 20.0-newton-meter minimum range and 0.2-newton precision; 360-degree working range in all joints; and environmental ratings of IP65 for the robot arm and IP44 for the control box with noise under 65 decibels (A). The vision system must scan at 3 hertz or faster with field of view of 179 × 115 to 282 × 175 millimeters or wider. The image processing computer requires an 8-core NVIDIA ARM Cortex-A78AE v8.2 64-bit CPU with 157 or more teraoperations per second performance, Ampere GPU with 1,024 CUDA cores and 32 tensor cores or better, 16 gigabytes memory, and 128 gigabytes SSD storage. The gripper must provide 85-millimeter stroke, 20–235-newton grip force, and 5-kilogram minimum grip payload. Vendors must submit capabilities statements, SAM registration confirmation, small business status certification, authorized distributor letters, and SDVOSB/VOSB certifications if applicable. Responses may indicate interest in Federal Supply Schedule quotes or open market purchases. No set-aside applies. Contract Specialist NaTasha Hawkins is the point of contact at Natasha.Hawkins@va.gov.

Notice text

2 versions

Update #2 · Latest ·

The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of Richmond VAMC for the Fredericksburg Health Care Center is conducting Market Research through this Sources Sought notice to help determine the availability of qualified Businesses, capable of providing an Industrial Collaborative Robot that meets the following: Salient Characteristics: Robot Physical Payload: 25kg (55.1 lbs) or greater Reach: 1750mm (68.9 in) or greater Degrees of Freedom: Minimum: 6 Base Footprint: 245mm diameter Electrical Power: 110-120 60Hz VAC Maximum Power: 750W Force Sensing (X-Y-Z) Range : ± 200.0N or higher Precision: ± 5.5N or lower Accuracy: ± 10.0N or lower Torque Sensing (X-Y-Z) Range : ± 20.0Nm or higher Precision: ± 0.2N or lower Accuracy: ± 0.1N or lower Motion: 360° working range in all joints and base Maximum Speed: ± 120°/s or better Pose Repeatability: Environmental: Robot Arm: IP65 or better Control Box: IP44 or better Noise: Less than 65 dB(A) Tool Mount Digital Input / Output: 2 / 2 or more Power: 12/24V @ 1A (single pin), 2A (dual pin) Control Box Digital Inputs / Outputs: 16 / 16 or more Analog Inputs / Outputs: 2 /2 or more Power 24V @ 2A Vision System Scan Rate: 3 Hz or faster Field of View: 179mm x 115- 282mm x 175 mm or wider X-Y Resolution: 0.074 - 0.121 mm or better Z Repeatability: 4.6 µm or less Software Features 3D feature measurement of holes, slots, cylinders, studs, threaded holes, and planes Volume measurement tools for areas, bounding boxes, and ellipses Digital Outputs: 2 or more Image Processing Computer CPU: 8-core NVIDIA Arm® Cortex®-A78AE v8.2 64-bit CPU 2MB L2 + 4MB L3 or better Performance (Tera Operations Per Second): 157 or more GPU: Ampere, 1024 CUDA cores, 32 Tensor cores or better Memory: 16 GB or more Nonvolatile Storage: 128 GB SSD or more Gripper Stroke: 85mm ± 10 mm Grip Force: 20 235 N or more Grip Payload: 5kG or more Fingertip Position Resolution: .4mm or less Closing Speed: 20 150 mm/s Environmental: IP40 or better Vibratory Parts Feeding System Part Compatibility Length: 10 to 110 mm Weight: 170 g or more Load Capacity: 7kg or more Infrared backlight Backlight Area: 922 cm2 or more Overall Outer Diameter: 788 or less Power: 110VAC Supply Air Pressure: 90PSI or less FDA compliant picking surface All respondents shall indicate/provide the following: Whether or not they are small business manufacturers of the products they wish to offer, or if they are a reseller of a small business manufacturer. Is your company interested in providing a Federal Supply Schedule (FSS) quote or Open Market (indicate FSS contract #)? Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services under the same or a related NAICS codes. Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services that are registered under the same or a related NAICS code with the Center for Veterans Enterprise (CVE); Provide the certification type (SDVOSB/VOSB), Federal Identification Number, and state of incorporation for each. Whether or not your company has an active SAM registration and the companies Unique Entity Identifier. A copy of its capabilities statement. Failure to provide the above information may result in the potential offeror being considered incapable of meeting the VA s needs. If the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered grey market and shall not be considered technically acceptable. The capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later than July 06, 2026, at 4:00 PM EST to the attention of: Natasha.Hawkins@va.gov Please title the subject line for all responses as: Industrial Collaborative Robot

Update #1 ·

The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of Richmond VAMC for the Fredericksburg Health Care Center is conducting Market Research through this Sources Sought notice to help determine the availability of qualified Businesses, capable of providing an Industrial Collaborative Robot that meets the following:

Salient Characteristics:

Robot

Physical

Payload: 25kg (55.1 lbs) or greater

Reach: 1750mm (68.9 in) or greater

Degrees of Freedom: Minimum: 6

Base Footprint: 245mm diameter

Electrical

Power: 110-120 60Hz VAC

Maximum Power: 750W

Force Sensing (X-Y-Z)

Range : ± 200.0N or higher

Precision: ± 5.5N or lower

Accuracy: ± 10.0N or lower

Torque Sensing (X-Y-Z)

Range : ± 20.0Nm or higher

Precision: ± 0.2N or lower

Accuracy: ± 0.1N or lower

Motion:

360° working range in all joints and base

Maximum Speed: ± 120°/s or better

Pose Repeatability:

Environmental:

Robot Arm: IP65 or better

Control Box: IP44 or better

Noise: Less than 65 dB(A)

Tool Mount

Digital Input / Output: 2 / 2 or more

Power: 12/24V @ 1A (single pin), 2A (dual pin)

Control Box

Digital Inputs / Outputs: 16 / 16 or more

Analog Inputs / Outputs: 2 /2 or more

Power 24V @ 2A

Vision System

Scan Rate: 3 Hz or faster

Field of View: 179mm x 115- 282mm x 175 mm or wider

X-Y Resolution: 0.074 - 0.121 mm or better

Z Repeatability: 4.6 µm or less

Software Features

3D feature measurement of holes, slots, cylinders, studs, threaded holes, and planes

Volume measurement tools for areas, bounding boxes, and ellipses

Digital Outputs: 2 or more

Image Processing Computer

CPU: 8-core NVIDIA Arm® Cortex®-A78AE v8.2 64-bit CPU

2MB L2 + 4MB L3 or better

Performance (Tera Operations Per Second): 157 or more

GPU: Ampere, 1024 CUDA cores, 32 Tensor cores or better

Memory: 16 GB or more

Nonvolatile Storage: 128 GB SSD or more

Gripper

Stroke: 85mm ± 10 mm

Grip Force: 20 235 N or more

Grip Payload: 5kG or more

Fingertip Position Resolution: .4mm or less

Closing Speed: 20 150 mm/s

Environmental: IP40 or better

Vibratory Parts Feeding System

Part Compatibility

Length: 10 to 110 mm

Weight: 170 g or more

Load Capacity: 7kg or more

Infrared backlight

Backlight Area: 922 cm2 or more

Overall Outer Diameter: 788 or less

Power: 110VAC

Supply Air Pressure: 90PSI or less

FDA compliant picking surface

All respondents shall indicate/provide the following:

Whether or not they are small business manufacturers of the products they wish to offer, or if they are a reseller of a small business manufacturer.

Is your company interested in providing a Federal Supply Schedule (FSS) quote or Open Market (indicate FSS contract #)?

Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services under the same or a related NAICS codes.

Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services that are registered under the same or a related NAICS code with the Center for Veterans Enterprise (CVE); Provide the certification type (SDVOSB/VOSB), Federal Identification Number, and state of incorporation for each.

Whether or not your company has an active SAM registration and the companies Unique Entity Identifier.

A copy of its capabilities statement.

Failure to provide the above information may result in the potential offeror being considered incapable of meeting the VA s needs.

If the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered grey market and shall not be considered technically acceptable.

The capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later than July 06, 2026, at 4:00 PM EST to the attention of: Natasha.Hawkins@va.gov

Please title the subject line for all responses as: Industrial Collaborative Robot

Files

File Type Posted
36C24626Q0729.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
J036--Sources Sought Preventative Maintenance of Mitsubishi Robots CMOP Lancaster-763 Department of Veterans Affairs Cmop Lancaster - 763 Lancaster TX 75134 · NAICS 811310 Veterans Integrated Service Network 15 No set-aside
6515--aesculap stainless steel surgical instruments Fredericksburg VA Health Care Center Veterans Health Administration Fredericksburg VA 22408, United States · NAICS 339113 Veterans Integrated Service Network 6 No set-aside
6515--NX EQ Image Guided Surgical Navigation System (VA-26-00083972) Nationwide · NAICS 334510 VA Strategic Acquisition Center Frederick Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity