6515--CANCELLATION: NX EQ Cryotherapy System: Tissue Ablation - Endoscopic
Closed Pre-Solicitation Posted
- Solicitation number
- 36C10G25Q0075
- Agency
-
Headquarters
Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
- Place of performance
- Enterprise-wide Conus and Oconus
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs (VA) is seeking to procure a Cryotherapy System: Tissue Ablation - Endoscopic for VA medical centers nationwide through a Requirements Contract with Firm-Fixed Price orders. The procurement targets the Varian CryoCare Touch Tissue Ablation System or equivalent medical device for use in various surgical procedures including oncology, urology, general surgery, and other medical specialties. Vendors must be registered in SAM, certified with NAICS code 334510, and SDVOSB/VOSB offerors must be verified in the SBA database. The evaluation will be conducted through a literature review process assessing eight salient characteristics covering safety, design, performance, and quality aspects of the equipment. Vendors are required to submit comprehensive technical documentation demonstrating compliance with the VA's specific requirements, including detailed product specifications, country of origin, and capabilities to provide uninterrupted national supply.
The solicitation does not include a specific set-aside designation and is open to manufacturers and distributors within the Electromedical and Electrotherapeutic Apparatus Manufacturing sector with up to 1,250 employees. The contract structure includes a 12-month base period with four additional 12-month option periods, contingent upon successful annual performance reviews. The procurement encompasses multiple contract line items including a control console, various cryoprobes of different lengths and configurations, temperature probes, procedure kits, and associated equipment. Specific quantities are defined for each line item, with baseline annual quantities ranging from 1 to 250 units depending on the specific equipment type. The VA's intent is to establish a comprehensive equipment solution that meets clinical functionality requirements across multiple medical disciplines, with the potential for additional beneficial product configurations to be proposed by vendors.
Notice text
2 versions
Update #2 · Latest ·
The purpose of this Amendment 0001 to the Sources Sought RFI posted to Contract Opportunities under RFI 36C10G25Q0075 is to cancel the RFI Sources Sought.
36C10G25Q0075 is cancelled. Responses will not be accepted or considered for market research purposes.
Update #1 ·
1.0 DESCRIPTION
The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Cryotherapy System: Tissue Ablation - Endoscopic product line as a candidate for the Department of Veterans Affairs VA-wide (otherwise referred to as national ) Non Expendable Equipment (NX) Requirements contract award.
The Department of Veterans Affairs (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources.
The SAC in conjunction with VHA is seeking a qualified source to provide Varian® brand name or equal CryoCare Touch Tissue Ablation System on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Cryotherapy System: Tissue Ablation - Endoscopic to VA medical centers and facilities throughout the United States.
The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.
The associated North American Industrial Classification System (NAICS) code for this procurement is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM prior to submitting an offer or proposal. You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.
This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.
2.0 SCOPE
Cryotherapy Tissue Ablation Systems are used for Cryoablation, a process that uses extreme cold (cryo) to destroy or damage tissue (ablation) whereby producing tissue necrosis at temperatures well below the freezing point of water (typically less than -20 degrees Celsius/-4 degrees Fahrenheit) using minimally invasive procedures. These systems typically consist of a central unit that provides the cryogen and includes electronic and mechanical components to perform and control the ablation; tubing to deliver the cryogen; and a probe (e.g., an applicator, needle, cannula, or catheter) to apply the cryogen directly or indirectly to the tissue. Ablation occurs when the cryogenic substance or cryogenic probe contacts the tissue. As the cells freeze, ice crystals form inside the cell and the subsequent cycle of freezing and thawing that follows actually destroys the tissue cells. Specifically, Cryotherapy System: Tissue Ablation - Endoscopic equipment are intended for use in open, minimally invasive or endoscopic surgical procedures in the areas of general surgery, urology, gynecology, oncology, neurology, dermatology, ENT, proctology, pulmonary surgery, and thoracic surgery for prostate and kidney tissue, liver metastases, tumors, skin lesions, and warts.
The following Contract Line Items are being considered:
Contract Line Item#
Brand
Part Number
Description
Base Year
Option Year I
Option Year II
Option Year III
Option Year IV
0001
Varian, Inc.
CRYO-38T
CryoCare Touch Tissue Ablation System (CryoCare Touch Control Console, 15-inch LCD Touchscreen Monitor with folding Monitor Arm, Side Handles to facilitate mobility, Wheels with Wheel Locks, Power Supply, Argon Port (with Regulator and Supply Line), Helium Port (with Regulator and Supply Line), Cryoprobe Interface with eight (8) Cryoprobe Connections, TempProbe Interface with eight (8) TempProbe Connections, Alarm Audio Output on Back Panel, Remote Keypads, CryoCare Touch System Software, and initial 1 YR Warranty)
2
2
2
2
2
0002
Varian, Inc.
CVA2400
Cryoprobe, Straight - Variable, 15 cm, 2.4 mm (8ft tubing)
100
100
100
100
100
0003
Varian, Inc.
CVA2400RA
Cryoprobe, V-Probe - Variable Right Angle, 15 cm, 2.4 mm (8ft tubing)
100
100
100
100
100
0004
Varian, Inc.
CVA2400RA-12
Cryoprobe, V-Probe - Variable Right Angle, 15 cm, 2.4 mm (12ft tubing)
50
50
50
50
50
0005
Varian, Inc.
PCS-17R
Cryoprobe, Right Angled Slimline, Round Ice, 15 cm, 1.7 mm
100
100
100
100
100
0006
Varian, Inc.
PCS-17RS
Cryoprobe, Right Angled Short Slimline, Round Ice, 7 cm, 1.7 mm
50
50
50
50
50
0007
Varian, Inc.
PCS-17
Cryoprobe, Right Angled Slimline, 15 cm, 1.7 mm
100
100
100
100
100
0008
Varian, Inc.
RS-17L
Cryoprobe, Right Angled Slimline, 20 cm, 1.7 mm
50
50
50
50
50
0009
Varian, Inc.
PCS-24
Cryoprobe, Right Angled Slimline, 15 cm, 2.4 mm
50
50
50
50
50
0010
Varian, Inc.
PCS-24L
Cryoprobe, Right Angled Long Slimline, 23 cm, 2.4 mm
25
25
25
25
25
0011
Varian, Inc.
R3.8
Cryoprobe, Right Angled, 13 cm, 3.8 mm
20
20
20
20
20
0012
Varian, Inc.
R3.8L
Cryoprobe, Right Angled Long, 28 cm, 3.8 mm
20
20
20
20
20
0013
Varian, Inc.
PC-2.1E
Cryoprobe, Isolis (Standard) Ellipsoidal, 15 cm, 2.1 mm
20
20
20
20
20
0014
Varian, Inc.
PC-2.1EL
Cryoprobe, Isolis (Long) Ellipsoidal 20 cm, 2.1 mm
20
20
20
20
20
0015
Varian, Inc.
PC-2.1S
Cryoprobe, Isolis (Standard) Spherical 15 cm, 2.1 mm
20
20
20
20
20
0016
Varian, Inc.
PC-2.1SL
Cryoprobe, Isolis (Long) Spherical 20 cm, 2.1 mm
20
20
20
20
20
0017
Varian, Inc.
CRYO-48-F
Cryoprobe, 29 cm, 8 mm
20
20
20
20
20
0018
Varian, Inc.
CRYO-55-F
TempProbe Short (for Direct Placement), 14.6 cm, 16 ga
250
250
250
250
250
0019
Varian, Inc.
CRYO-204V
Cryoablation Procedure Kit Variable (4 x CVA2400, 4 x Cryo-55F, 1 x Cryo-77)
25
25
25
25
25
0020
Varian, Inc.
CRYO-207V
Cryoablation Procedure Kit Variable (6 x CVA2400, 6 x Cryo-55F, 1 x Cryo-77)
25
25
25
25
25
0021
Varian, Inc.
DP35-0551-111
Regulator, 1700 PSI with Filter
1
1
1
1
1
0022
Varian, Inc.
DP35-0551-112
Regulator, 3100 PSI with Filter
1
1
1
1
1
0023
Varian, Inc.
DP35-0551-905
Helium Regulator with Relief Valve
1
1
1
1
1
0024
Varian, Inc.
DP35-0551-906
Helium Supply Hose
1
1
1
1
1
0025
Varian, Inc.
DP35-0551-907
Argon Regulator with Relief Valve
1
1
1
1
1
0026
Varian, Inc.
DP35-0551-908
Argon Regulator without Relief Valve
1
1
1
1
1
0027
Varian, Inc.
DP35-0551-909
Argon Supply Hose
1
1
1
1
1
0028
Varian, Inc.
CRYO-77
Uretheral Warming Catheter
50
50
50
50
50
0029
Varian, Inc.
CRYO-EQ
Cryoablation Equipment Rental (per case if required)
25
25
25
25
25
0030
Varian, Inc.
CRYO-SVC
Technical Support Services Fee (per case, if needed)
25
25
25
25
25
0031
Varian, Inc.
CRYO-WARR
(1) One Year Warranty and Service Maintenance for CryoCare Touch with Annual On-Site Preventative Maintenance Service.
10
10
10
10
10
The VA is seeking vendors who can provide Varian Medical Systems® CryoCare Touch Tissue Ablation System or equal as listed above which meet all the following salient characteristics:
CLIN 0001 applies to SCs 1-5
CLINs 0002-0020 applies to SC 6
CLIN 0031 applies to SC 8
SC #
SALIENT CHARACTERISTICS
METHOD OF EVALUATION
SC 1
Must provide high quality cryoablation treatment to efficiently ablate liver, prostate, kidney, and other soft tissue and tumors
Literature Review
SC 2
Must have a user-friendly / intuitive touchscreen user interface with integrated temperature, power, and timer to monitor, display, and control therapy duration
Literature Review
SC 3
Must provide audible and visual alarms and warnings
Literature Review
SC 4
Must include a dedicated mobile system or console cart, easy to roll with adequate space for components and tanks. Cart must have locking casters
Literature Review
SC 5
Must use a medical grade power cord and use standard electrical wall outlet - 110V-120V circuit, 120V 60Hz AC input
Literature Review
SC 6
Must provide probes / applicators / needles of various lengths including equal to or longer than 23 cm with a quick release and connect capability
Literature Review
SC 7
Must be FDA approved. Must demonstrate compliance with requirements of widely accepted product safety standards, as determined through independent testing by organizations such as the American National Standards Institute (ANSI), Underwriters Laboratories (UL), American Section of the International Association for Testing Materials, and International Electrotechnical Commission (IEC)
Literature Review
SC 8
Manufacturer Warranties - should outline any length and coverage of warranties/guarantees associated with their products, as these can provide assurance of quality and reliability to the government
Literature Review
Evaluation Sub-factors:
Safety All safety features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:
Power and Temperature Sensors
Probe/Applicator/Needle Power Settings for Ice Formation Control
Design All design features and functions of the offered device will be evaluated. Areas may include but are not limited to the following:
Centralized Control / Consolidated Touchscreen User Interface
Availability of Various Probe/Applicator/Needle Sizes (length and gauged thickness)
Supports the Simultaneous use of Multiple Probes/Applicators/Needles
Cryo/Cooling System
Availability of Distal Energy Control and Ice-Ball Formation
Capable of Storing/Retrieving Case Logs
Space Requirements / Footprint
Performance Device will be evaluated for its ability to perform its intended function. Areas may include but are not limited to:
System Cart Mobility and Functionality
Ease of Use / Streamlined Workflow
Ability to be Sanitized Using Hospital Approved Disinfectants/Cleaners
Quality/Construction All aspects of construction and quality of material of the device will be evaluated. Areas may include but are not limited to the following:
Life Span / Durability
Training
Service Program
For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.
The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.
Responses to this Sources Sought Notice shall include the following:
Full name and address of company;
Unique Entity Identifier (UEI) number;
Business Size;
Manufacturer or Distributor;
If distributor provide full name, business size and address of manufacturer.
Country of Origin designation for all products;
Ability to provide uninterrupted supply of products on a national scale;
Technical Literature that clearly shows product(s) meet the identified SCs (if submitting an or-equal item);
Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.
Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.
Files
| File | Type | Posted |
|---|---|---|
| 36C10G25Q0075 0001.docx | DOCX document | |
| 36C10G25Q0075.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 6515--NX EQ Image Guided Surgical Navigation System (VA-26-00083972) | VA Strategic Acquisition Center Frederick | Service-Disabled Veteran-Owned Small Business | |
| 6515 - Intent to Sole Source - Siemens Skyra Coldhead RDE-412L4 (11472997 | Veterans Integrated Service Network 21 | No set-aside | |
| 6515--Anesthesia Units Extend due date/time | Veterans Integrated Service Network 1 | No set-aside | |
| J066--Azenta NitroStore System PM and Support Services | Veterans Integrated Service Network 4 | No set-aside | |
| Q999--MO | Surgical Laser Service | 663 5 year IDIQ : 2/11/2027-2/10/2032 | Veterans Integrated Service Network 20 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity