6515-- Muscle and Nerve Stimulator
Closed Pre-Solicitation Posted
- Solicitation number
- 36C25625Q1028
- Agency
-
Veterans Integrated Service Network 16
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
- Place of performance
- Veterans Health Care System of the Ozarks Fayetteville AR 72703
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16 has issued a Sources Sought Notice for one muscle and nerve stimulator device to support the Whole Health Service at Veterans Healthcare System of the Ozarks in Fayetteville, Arkansas. The procured equipment must perform a full range of chiropractic procedures and therapeutic functions, meeting stringent technical specifications including visual LED displays, acoustic tone indicators, operating switches with 21 therapy selection keys, four intensity control knobs, dual outputs for stimulating current application, and FDA Class II Device classification. The device must operate on 230V or 110V power with specific electrical characteristics including sinusoidal alternating current capabilities and nominal intensity range of 0-90 mA at 500 Ohm. The government seeks to identify qualified sources and their business size classifications under NAICS code 334510 (Electromedical and Electrotherapeutic Apparatus Manufacturing) with a size standard of 1,250 employees. Interested firms must submit comprehensive responses including company information, capability statements, and manufacturer authorization documentation to Contract Specialist Michelle Atwell by 1:00 PM Central Time on July 11, 2025.
This procurement opportunity is designated as a Total Small Business set-aside, with particular interest in Service Disabled/Veteran Owned Small Businesses (SDVOSB/VOSB), HubZone, 8(a), small disadvantaged, and woman-owned small businesses. The notice does not identify any incumbent contractors or current service providers for this requirement. No budget range or estimated contract value has been disclosed in the Sources Sought Notice, as this is purely an information-gathering exercise to assess market capabilities. The requirement involves procuring a single unit of specialized medical equipment with precise dimensional specifications of 10 cm height, 42 cm width, and 30 cm depth. The government emphasizes that this notice is not a solicitation and responses will be used solely to inform future acquisition decisions, with any resulting solicitation to be announced separately on appropriate federal contracting platforms.
Notice text
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.
DESCRIPTION: This notice is not a solicitation as defined by FAR 2.101, therefore it shall not be construed as a commitment by the Government to enter into a contract, nor does it restrict the Government to an acquisition approach. All information contained in this sources sought is preliminary as well as subject to amendment and is in no way binding on the Government. Information submitted in response to this notice is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. The Government is requesting that restrictive or proprietary markings not be used in response to this notice. If a solicitation is released, it will be synopsized in the Federal Contract Opportunities website, NASA SEWP, or GSA. It is the responsibility of the interested parties to monitor these sites for additional information pertaining to this sources sought.
1. Title:Â Muscle and Nerve Stimulator
2. Purpose: The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classification, Service Disabled/Veteran Owned Small Business. (SDVOSB/VOSB), Hubzone, 8(a), small, small disadvantage, woman owned small business, or large business) relative to NAICS 334510, Surgical and Medical Instrument Manufacturing. Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought synopsis, a solicitation announcement may be published on GSA eBUY or Contract Opportunities website. Responses to this source sought synopsis are not considered adequate responses to the solicitation announcement. All interested offerors must respond to the solicitation announcement in addition to responding to this source sought announcement.
Background:
The Whole Health Service at Veterans Healthcare System of the Ozarks (VHSO) requires 1 muscle and nerve stimulator device to perform a full range of chiropractic procedures and other therapeutic functions, to provide Brand Name or Equal Muscle and Nerve Stimulators. The requested item will be used at Veterans Health Care System of the Ozarks, 1100 N. College Avenue, Fayetteville, AR 72703.
3. Salient Characteristics:
Must have Visual Displays. A yellow LED indicates "output voltage can exceed 10Vi."
Must have Acoustic Displays. When switching on the device after successful automatic test: 2 tones, 1 second apart. Error discovered in automatic test: 1 tone, 2 seconds. Start of treatment with intensity control: 1 tone, 0.5 seconds. End of treatment: 5 tones each of 0.5 seconds with pauses of 0.5 seconds. Intensity interval: 1 tone, 0.5 seconds - dose error by device: continuous tone until the device or the intensity has been turned off manually.
Must have Operating Switches One black on/off rocker switch. 21 therapy selection plastic-covered keys.
Must have Control Knobs. 4 intensity control knobs.
Application Pane. 2 separate outputs for stimulating current application.
Output Sockets. 2 x 5 pole socket for electrode connection. 2 x 5 pole socket for connection with a vacuum device (rear panel).
Initial Curve Profile and Frequency. Sinusoidal alternating current for St, StT, if, Mf, MfT, all programs and Mf test. For St and StT: red circuit and white circuit 4000Hz amplitude-modulated with a frequency of 0.1-200Hz. For Mf and MfT: red circuit and white circuit 4000Hz. For if: white circuit 3800 - 4000 Hz, red circuit 4000Hz.
Nominal Intensity Range. 0 - 90 mA at 500 Ohm with depth selection not operating.
Nominal Output. In the RED circuit and WHITE circuit at 500 Ohm each 4.05VA.
Ability for Switching off the Intensity. If intensity increases by 50% of the set level due to device error. If intensity variations occur during a pause by the interval timer and the treatment time repeat intervals. If device is put into operation by connection of the mains plug with the mains supply. On return of power after supply breakdown.
Classification FDA Class II Device.
Voltage. 230V or 110V / 50 - 60 Hz, 70 VA.
Mains Fuses - 2 x T. 0.63 A.
Secondary Circuit Safety Fuses. 1 x T 4A, 1 x MT 1.6A.
Measurements. H 10 cm, B 42 cm, T 30 cm.
All interested firms who can meet the requirements stated above should respond, in writing,
INCLUDING ALL THE FOLLOWING:
Company name.
Address.
Point of contact (name/title/telephone number/e-mail address).
FSS / SEWP Contract number, if applicable.
SAM Unique ID number.
Tax ID number.
Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies.
A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above.
Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer.
Submit responses to the Contract Specialist, Michelle Atwell, at michelle.atwell@va.gov no later than 1:00 PM (Central Time), 11 July 2025.
36C255625Q1028 [Muscle and Nerve Stimulator] shall be referenced on all correspondence regarding this announcement.
TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED.
The NAICS Code 334510, Electromedical and Electrotherapeutic Apparatus Manufacturing, is applicable to this acquisition; the size standard is 1,250 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.
Files
| File | Type | Posted |
|---|---|---|
| 36C25625Q1028_1.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Electro-Therapeutic Modalities for Pain Management (ETMPM) - Transcutaneous Electrical Nerve Stimulation (TENS) Procurement Program | Veterans Integrated Service Network 19 | No set-aside | |
| Sources Sought for Cefaly Devices at VA Puget Sound | Veterans Integrated Service Network 20 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity