6515--bedside monitors for HCC activaton
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- 36C24624Q1007
- Agency
- Veterans Integrated Service Network 6 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
- Place of performance
- Fredericksburg Hcc Fredericksburg, Virginia 22408, United States
- Points of contact
-
- Donald V Harris donald.harris@va.gov (757) 251-4136
Notice details come from SAM.gov. Updated .
About this opportunity
Paragraph 1:
The Department of Veterans Affairs Network Contracting Office 6 is conducting market research to identify qualified vendors that can provide bedside patient monitors and a central monitoring system for the new Fredericksburg Health Care Center. The government is seeking Philips MX750 bedside monitors and Philips PIC IX central monitoring systems with specified technical requirements and functionality, including compatibility with electronic medical records, data transmission capabilities, and advanced monitoring features. Responses are due by 9 AM EDT on July 3, 2024, and must include company details, capabilities, socioeconomic status, and applicable contract vehicles. The information gathered may be used in a future solicitation, but this is not a solicitation and no contract will be awarded based on these responses.
Paragraph 2:
This pre-solicitation notice does not include any set-aside designations. The applicable NAICS code is 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing, with a small business size standard of 1,250 employees. No potential incumbents or current contractors are named, and the government has not provided any information about the potential award value or budget range for this procurement. The quantity of goods or timeline for services is also not specified in the notice.
Notice text
DISCLAIMER
THIS NOTICE IS FOR PLANNING PURPOSES ONLY. THE GOVERNMENT DOES NOT INTEND TO AWARD A CONTRACT ON THE BASIS OF THIS SOURCES SOUGHT OR REIMBURSE ANY COSTS ASSOCIATED WITH THE PREPARATION OF RESPONSES TO THIS NOTICE.
This Sources Sought notice is issued solely for information and planning purposes and does not constitute the Government will contract for the items contained in this announcement.
PURPOSE:
The purpose of this notice is to conduct market research to find qualified vendors and to assist Network Contracting Office (NCO) 6 in determining if a future contract effort can be competitively awarded. The applicable North American Industrial Classification System (NAICS) code assigned to this effort is 334510 with the Small Business Size Standard of 1,250 employees. If the Government determines there are qualified vendors with this requirement, a solicitation will may be published and posted on the Contracting Opportunities website https://sam.gov/content/home . The Government will use this information solely to determine the appropriate acquisition strategy for this procurement.
INTRODUCTION:
The Richmond VA Medical Center/Healthcare System (RVAHCS) has a new requirement for Bedside Vitals Monitoring and associated hardware and software. This requirement is needed for the new Fredericksburg Health Care Center (HCC) activation.
REQUIREMENTS:
NOTE: The VHA Network Contracting Office 6 (NCO 6) is conducting a market survey to find qualified vendors who can provide the following item(s) to the Fredericksburg HCC 11432 Patriot Highway Fredericksburg, VA 22408.
Salient Characteristics:
Philips MX750s
Functions to be performed;
A bedside patient monitor that clearly displays live vital signs and other relevant patient data. The monitor must be capable of sending data to both the electronic medical record (EMRs) as well as any patient data management systems (PDMs)
Performance required;
Must be compatible with Current Operating room EMR documentation system (PICIS).
Must be capable of sending data to clinical information systems (Clinicomp, or equivalent)
Must be capable of recording onto paper strips or electronic.
Must be able to customize alarms.
Must be able to transmit data to central monitoring stations (i.e., a nurse s station).
Must be capable of recording:
Blood Pressure (Invasive and Non-Invasive)
Heart Rate
Respiration Rate
ECG
Sp02
End Tidal CO2
Temperature
Cardiac Output
and Arrythmia monitoring
Essential physical characteristics; Dimensions (if applicable)
19 full-color project capacitive (PCAP) touchscreen
Screen must have a resolution of at least 1920 x 1080.
The monitor must weigh no more than 22 lbs (with out accessories)
Must be able to display up to 12 waveforms.
Must be able to hold up to 8 different modules.
Built-in handle for in-hospital transport
Ambient light sensor automatically adjusts screen brightness to maintain readability in nearly any lighting environment.
Must have built-in advanced clinical solutions to summarize and visualize clinical data.
Philips PIC IX
Functions to be performed:
A central monitoring system that can receive, aggregate, process, display, and distribute physiologic waves, parameters, alarms, and events for multiple patients within a local area network. This system is comprised of a family of servers, central monitoring workstations, and network switches to connect the bedside monitors to the central viewing stations.
Performance required:
The system must have the ability to review, capture, and export diagnostic quality ECG monitoring.
The system must be able to deliver rapid reliable interpretations of the ECG to determine real time cardiac signal abnormalities.
The system must be able to integrate with the Electronic Health Record (EHR).
The system must be able to show waves and physiological measurement information from bedside monitors within the local area network (LAN). Measurements include blood pressure, heart rate, respiration rate, ECG, Sp02, capnography, temperature, cardiac output, and arrythmia monitoring.
The central monitoring stations must display patient alarms that have been detected by bedside monitors within the LAN.
Essential physical characteristics; Dimensions (if applicable):
The central monitoring workstations must be able to display up to 14 patient sectors (pre-op holding)
The central monitoring workstations must be able to display up to 4 waveforms for each patient sector, and up to 12 total measurements.
The system must be able to print to a full-color laser jet printer.
The central monitoring workstations must have a display size of at least 24
The central monitoring workstations must have a supported operating system (Microsoft Windows 10 LTSB, or equivalent)
The server(s) must be a supported operating system (MS Server 2019, or equivalent)
Equipment List:
Line-Items ITEM DESCRIPTION
1) PATIENT INFORMATION CENTER IX - 866389
2) RV4 PIC iX SOFTWARE RELEASE 4
3) NEW INSTALL
4) 1X4 PIC IX ENTERPRISE - 389-1x4
5) NTP NETWORK 389-NTP
6) OVR OVERVIEW
7) PRO 389-PRO
8) PIC IX HARDWARE, TO INCLUDE PIC IX 4- RV4; RV4, NE - 866424
9) NEW HARDWARE OR OS
10) HVM VMWARE SERVER
11) HS1 PC HARDWARE WITH SSD
12) HPS LITHIUM ION UPS - 424-HPS
13) INTELLIVUE MX750 PATIENT MONITOR
14) H32 ANESTHESIA SOFTWARE
15) CP2 EXTENDED ECG CAPABILITIES
16) CP4 EXT. ALARMING CAPABILITIES
17) A08 8-WAVE CAPABILITY
18) J13 RS232/MIB INTERFACE 47-J13
19) INTELLIVUE MX750 PATIENT MONITOR 866471
20) H32 ANESTHESIA SOFTWARE
21) CP2 EXTENDED ECG CAPABILITIES
22) CP4 EXT. ALARMING CAPABILITIES
23) A08 8-WAVE CAPABILITY
24) J13 RS232/MIB INTERFACE 471-J13
25) J15 REPLICA DISPLAY
26) INTELLIVUE FMX-4
27) E20 MULTI MEASUREMENT MODULE MT
28) INTELLIVUE X3
29) A-04 WAVES CAPABILITY
30) H72 CRITICAL CARE TRASNPORT SW
31) B06 DUAL PRESS AND TEMP
32) SP1 FAST SPO2
33) CABLES FOR INTELLIVUE
34) SC1 SYSTEM CABLES 0.75
35) INTELLIVUE MICROSTREAM EXTENSION
36) B06 ADD DUAL IBP, TEMP
37) THERMAL ARRAY RECORDER MODULE
38) INTELLIVUE BIS MODULE
39) BO1 BIS DEVICE
40) K20 BIS 4-ELECTRODE SENSORS
41) INTELLIVUE NMT MODULE
42) K01 NMT PATIENT CABLE
43) INTELLIBRIDGE ECS ID- MODULE
44) 412 DRAEGER PERSEUS A500 IDM
45) L01 CONNECTION CABLES, 1.5M
46) INTELLIBRIDGE EC10 MODULE
47) A01 EC10 MODULE RS232/LAN
48) 412 DRAEGER PERSEUS A500 DRY
49) ADULT NIBP AIR HOSE, 3.0M
50) EASY CARE CUFF, 1 HOSE, SMALL ADULT (1)
51) EASY CARE CUFF, 1 HOSE, ADULT (1)
52) EASY CARE CUFF,1 HOSE, LRG ADULT (1)
53) EASY CARE CUFF, 1 HOSE, ADULT XL (1)
54) EASY CARE CUF, 1 HOSE, THIGH (1)
55) CBL OR 5-LEAD ECG TRUNK CABLE, AAMI/IEC
56) CBL 5 LEADSET, GRABBER,
57) CBL 5 LEAD ECG TRUNK, AAMI/IEC 2.7M
58) SP02 8-PIN D-SUB ADAPTER CABLE 3M (8PIN)
59) SP02 REUS ADULT CLIP SENSOR M1196T
60) INTELLIBRIDGE ENTERPRISE
NEW INTELLIBRRIGE
61) NEW SYSTEM
62) A01 ADT SYSTEM LICENSE
63) A04 EMR SYSTEM LICENSE
64) P03 PIIC PATIENT ID MATCHING
65) P02 PIIC IX 128 BEDS LICENSE
66) OR CARE AREA PACKAGES
67) A01 OR CAREAREA PACKAGES
68) CLIN CONFIGURATION & IMP: CREATE CUSTOM SCREENS
69) IBE SYSTEM INTEGRATION SERVICES
70) A02 ADT LICENSE/CONFIGURATION
71) P02 PIICIX PAT IDENTITY MATCH
72) P12 PIIC/PIIC IX 128 BED CONFIGURATION
73) PRO ARM SOLUTION, VHM DUAL FMX-4
74) PRO REMOTE PC SOLUTION W/CABLING
75) PRESEUS: MX600-850, DUAL FMX-4 SIDE
76) DISPLAY 23" HP, NON-TOUCH 1920X1080
77) CABLE: HW, MATS, LABOR, TENT, TEST
78) NETWORK: HARDWIRED (PER BED)
79) CSN: VIRTUAL CONSULT/ VALIDATE
80) PSN: DIRECT CONNECT SERVICES
81) PROJECT MANAGEMENT INTEGRATED
82) LABOR: INSTALL EQUIPMENT
83) IBE: NEW IMPLEMENTATION PACKAGE
HOW TO RESPOND:
All responses shall be submitted no later than 9 am EDT Wednesday 03 July 2024. All interested parties should respond, in writing via email to donald.harris@va.gov . No telephone inquiries will be accepted. Respondents to this RFQ SS shall provide the following information:
Company/individual name,
Address,
Point of contact with phone number
Information describing your interest,
Indicate FSS/GSA contract number or Open Market, as applicable
FSS Category you qualify for
Tax ID number
UEI number
Capabilities statement
Company Socio-Economic SIZE (example large, small, SDVOSB, VOSB, WOSB etc.)
Interested firms are reminded that in accordance with FAR 4.1201(a) Prospective contractors shall complete electronic annual representations and certifications at the System for Award Management (SAM) as a part of required registration in conjunction with FAR 4.1102(a) that states, Prospective contractors shall be registered in the (SAM) database prior to award of a contract or agreement. Therefore, due to time constraints, vendors must be registered in System for Award Management (SAM) under the above NAICS code at http://www.sam.gov to be considered for an award.
Please submit responses via email in by 9:00AM (Eastern Standard Time) 07/03/2024. Please include SS# 36C24624Q1007 in subject title.
NOTE: Information obtained as a result of this announcement may be reflected in any subsequent solicitation. This announcement is for government market research purposes ONLY.
Attachments
| File | Type | Posted |
|---|---|---|
| 36C24624Q1007.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 6515--phillips monitors for HCC activaton | Award Notice | |
| 6515--philips intellivue MX750 bedside monitors for fredricksburg health care center activaton | Solicitation | |
| 6515--philips intellivue MX750 bedside monitors for fredricksburg health care center activaton | Pre-Solicitation | |
| 6515--bedside monitors for HCC activaton | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity